Magnetoneurography of evoked compound action currents in human cervical nerve roots

被引:21
作者
Mackert, BM [1 ]
Burghoff, M
Hiss, LH
Nordahn, M
Marx, P
Trahms, L
Curio, G
机构
[1] Free Univ Berlin, Klinikum Benjamin Franklin, Neurophys Grp, D-12203 Berlin, Germany
[2] Free Univ Berlin, Klinikum Benjamin Franklin, Dept Neurol, D-12203 Berlin, Germany
[3] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
magnetoneurography; magnetic field; cervical root; SQUID (superconducting quantum interference device); median nerve; ulnar nerve;
D O I
10.1016/S1388-2457(00)00530-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: A measurement protocol for magnetoneurography (MNG) is established which allows the non-invasive localization and tracing of evoked compound action currents propagating along cervical nerve roots in man. Methods: Inside a magnetically shielded room either both median or both ulnar nerves of healthy subjects were conventionally electrostimulated in alternation. Evoked magnetic responses were recorded using a multichannel SQUID-detector with a planar measuring area centered over the neck. Simultaneously, electric surface potentials were recorded using cervical bipolar electrode montages. Results: Upon median (ulnar) nerve stimulation somatosensory evoked magnetic fields up to 20 fT (10 fT) amplitude were detected propagating over the cervical transforaminal root entry zone, with corresponding electrical surface potentials of 1.5 muV (0.5 muV). Furthermore, the signal-to-noise ratio of the spatiotemporal magnetic field mappings in median nerve stimulation experiments allowed dipolar source reconstructions and tracing of the propagation of the compound action currents along nerve root fibers. Conclusion: Magnetoneurography allows tracing of the propagation of evoked compound action currents along cervical roots in healthy subjects with millisecond temporal and high spatial resolution. Thus, MNG offers a sensitivity appropriate to serve as a clinical diagnostic tool for localizing focal neuropathies of cervical nerve roots. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:330 / 335
页数:6
相关论文
共 21 条
[11]  
GRABE T, 1997, ADV MATH TOOLS METRO, V3, P178
[12]   MULTICHANNEL DETECTION OF MAGNETIC COMPOUND ACTION FIELDS OF MEDIAN AND ULNAR NERVES [J].
HARI, R ;
HALLSTROM, J ;
TIIHONEN, J ;
JOUTSINIEMI, SL .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1989, 72 (03) :277-280
[13]   VISUALIZATION OF A MOVING QUADRUPOLE WITH MAGNETIC MEASUREMENTS OF PERIPHERAL-NERVE ACTION FIELDS [J].
HASHIMOTO, I ;
MASHIKO, T ;
MIZUTA, T ;
IMADA, T ;
IWASE, K ;
OKAZAKI, H .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1994, 93 (06) :459-467
[14]   Mapping of tibial nerve evoked magnetic fields over the lower spine [J].
Mackert, BM ;
Curio, G ;
Burghoff, M ;
Marx, P .
EVOKED POTENTIALS-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1997, 104 (04) :322-327
[15]   Magnetoneurographic 3D localization of conduction blocks in patients with unilateral S1 root compression [J].
Mackert, BM ;
Curio, G ;
Burghoff, M ;
Trahms, L ;
Marx, P .
ELECTROMYOGRAPHY AND MOTOR CONTROL-ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 109 (04) :315-320
[16]   Non-invasive magnetoneurography for 3D-monitoring of human compound action current propagation in deep brachial plexus [J].
Mackert, BM ;
Burghoff, M ;
Hiss, LH ;
Nordahn, M ;
Trahms, L ;
Curio, G .
NEUROSCIENCE LETTERS, 2000, 289 (01) :33-36
[17]  
MACKERT BM, 1993, BIOMED ENG S1, V38, P201
[18]   THE HUMAN POSTERIOR TIBIAL SOMATOSENSORY EVOKED-POTENTIAL - SYNAPSE DEPENDENT AND SYNAPSE INDEPENDENT SPINAL COMPONENTS [J].
SEYAL, M ;
GABOR, AJ .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1985, 62 (05) :323-331
[19]   BIOMAGNETIC FUNCTIONAL LOCALIZATION OF A PERIPHERAL-NERVE IN MAN [J].
TRAHMS, L ;
ERNE, SN ;
TRONTELJ, Z ;
CURIO, G ;
AUST, P .
BIOPHYSICAL JOURNAL, 1989, 55 (06) :1145-1153
[20]   Signal-space projection method for separating MEG or EEG into components [J].
Uusitalo, MA ;
Ilmoniemi, RJ .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1997, 35 (02) :135-140