Low-osmolar monomeric versus iso-osmolar dimeric contrast media: An intra-individual comparison in CT angiography using an animal model

被引:5
作者
Behrendt, Florian F. [2 ,3 ]
Pietsch, Hubertus [4 ]
Jost, Gregor [4 ]
Keil, Sebastian [2 ]
Mottaghy, Felix M. [3 ]
Guenther, Rolf W. [2 ]
Mahnken, Andreas H. [1 ,2 ]
机构
[1] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, Dept Appl Med Engn, Aachen, Germany
[2] Aachen Univ Hosp, Dept Radiol, Aachen, Germany
[3] Aachen Univ Hosp, Dept Nucl Med, Aachen, Germany
[4] Bayer Schering Pharma AG, Berlin, Germany
关键词
arteries; contrast agents-intravenous; CT angiography; vascular; COMPUTED-TOMOGRAPHY; IODINE CONCENTRATION; ENHANCEMENT; IODIXANOL-320; AGENTS;
D O I
10.1111/j.1754-9485.2011.02247.x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The aim of this study was to compare intra-individual contrast enhancement in multidetector-row computed tomography using the low-osmolar monomeric iopromide 300 and the iso-osmolar dimeric iodixanol 320. Methods: Repeated computed tomography scanning of the chest of five pigs was performed under standardised conditions using iopromide 300 (300 mg I/mL) and iodixanol 320 (320 mg I/mL) with an identical iodine delivery rate of 1.5 g I/sec and a total iodine dose of 300 mg/kg body weight. Time-enhancement curves were computed, and pulmonary and aortic peak enhancement, time-to-peak and plateau time above 300 Hounsfield units (HU) were analysed. Results: Intra-individual comparison revealed no statistically significant differences in contrast enhancement between the iopromide 300 and iodixanol 320 in the pulmonary artery and the aorta (620 vs 552 HU; P = 0.13). There was no significant difference between the two CM in the plateau time at the pulmonary artery and the aorta (P = 0.75 and P = 0.24, respectively). Aortic peak time was significantly earlier with iopromide 300 than with iodixanol 320 (P = 0.004). Conclusions: Low-osmolar monomeric and iso-osmolar dimeric CM provide a similar and suitable vascular contrast enhancement.
引用
收藏
页码:170 / 175
页数:6
相关论文
共 19 条
[1]   Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor-to-liver contrast at multi-detector row CT [J].
Awai, K ;
Inoue, M ;
Yagyu, Y ;
Watanabe, M ;
Sano, T ;
Nin, S ;
Koike, R ;
Nishimura, Y ;
Yamashita, Y .
RADIOLOGY, 2004, 233 (03) :682-688
[2]   Intraindividual comparison of contrast media concentrations for combined abdominal and thoracic MDCT [J].
Behrendt, Florian F. ;
Mahnken, Andreas H. ;
Stanzel, Sven ;
Seidensticker, Peter ;
Jost, Edgar ;
Guenther, Rolf W. ;
Muehlenbruch, Georg .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) :145-150
[3]   Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCT [J].
Behrendt, Florian F. ;
Pietsch, Hubertus ;
Jost, Gregor ;
Sieber, Martin A. ;
Keil, Sebastian ;
Plumhans, Cedric ;
Seidensticker, Peter ;
Guenther, Rolf W. ;
Mahnken, Andreas H. .
EUROPEAN RADIOLOGY, 2010, 20 (07) :1644-1650
[4]   Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise [J].
Benner, T ;
Heiland, S ;
Erb, G ;
Forsting, M ;
Sartor, K .
MAGNETIC RESONANCE IMAGING, 1997, 15 (03) :307-317
[5]   High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography - Iopromide 370 versus iomeprol 400 [J].
Cademartiri, F ;
de Monye, C ;
Pugliese, F ;
Mollet, NR ;
Runza, G ;
van der Lugt, A ;
Midiri, M ;
de Feyter, PJ ;
Lagalla, R ;
Krestin, GP .
INVESTIGATIVE RADIOLOGY, 2006, 41 (03) :349-353
[6]   HEPATIC CT ENHANCEMENT - COMPARISON OF IONIC AND NONIONIC CONTRAST AGENTS IN THE SAME PATIENTS [J].
CHAMBERS, TP ;
BARON, RL ;
LUSH, RM ;
DODD, GD ;
MILLER, WJ .
RADIOLOGY, 1994, 190 (03) :721-725
[7]   HEPATIC CT ENHANCEMENT - A METHOD TO DEMONSTRATE REPRODUCIBILITY [J].
CHAMBERS, TP ;
BARON, RL ;
LUSH, RM ;
DODD, GD ;
MILLER, WJ ;
CONFER, SR .
RADIOLOGY, 1993, 188 (03) :627-631
[8]   Nephrotoxicity of Iso-osmolar Iodixanol Compared with Nonionic Low-osmolar Contrast Media: Meta-analysis of Randomized Controlled Trials [J].
Heinrich, Marc C. ;
Haeberle, Lothar ;
Mueller, Volker ;
Bautz, Werner ;
Uder, Michael .
RADIOLOGY, 2009, 250 (01) :68-86
[9]   Influence of osmolarity of contrast medium and saline flush on computed tomography angiography: Comparison of monomeric and dimeric iodinated contrast media with different iodine concentrations at an identical iodine delivery rate [J].
Kishimoto, Miori ;
Doi, Shoko ;
Shimizu, Junichiro ;
Lee, Ki-Ja ;
Iwasaki, Toshiroh ;
Miyake, Yoh-Ichi ;
Yamada, Kazutaka .
EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (01) :135-139
[10]   Renal failure in 57 925 patients undergoing coronary procedures using iso-osmolar or low-osmolar contrast media [J].
Liss, P. ;
Persson, P. B. ;
Hansell, P. ;
Lagerqvist, B. .
KIDNEY INTERNATIONAL, 2006, 70 (10) :1811-1817