Low-osmolar monomeric versus iso-osmolar dimeric contrast media: An intra-individual comparison in CT angiography using an animal model

被引:5
作者
Behrendt, Florian F. [2 ,3 ]
Pietsch, Hubertus [4 ]
Jost, Gregor [4 ]
Keil, Sebastian [2 ]
Mottaghy, Felix M. [3 ]
Guenther, Rolf W. [2 ]
Mahnken, Andreas H. [1 ,2 ]
机构
[1] Rhein Westfal TH Aachen, Helmholtz Inst Biomed Engn, Dept Appl Med Engn, Aachen, Germany
[2] Aachen Univ Hosp, Dept Radiol, Aachen, Germany
[3] Aachen Univ Hosp, Dept Nucl Med, Aachen, Germany
[4] Bayer Schering Pharma AG, Berlin, Germany
关键词
arteries; contrast agents-intravenous; CT angiography; vascular; COMPUTED-TOMOGRAPHY; IODINE CONCENTRATION; ENHANCEMENT; IODIXANOL-320; AGENTS;
D O I
10.1111/j.1754-9485.2011.02247.x
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: The aim of this study was to compare intra-individual contrast enhancement in multidetector-row computed tomography using the low-osmolar monomeric iopromide 300 and the iso-osmolar dimeric iodixanol 320. Methods: Repeated computed tomography scanning of the chest of five pigs was performed under standardised conditions using iopromide 300 (300 mg I/mL) and iodixanol 320 (320 mg I/mL) with an identical iodine delivery rate of 1.5 g I/sec and a total iodine dose of 300 mg/kg body weight. Time-enhancement curves were computed, and pulmonary and aortic peak enhancement, time-to-peak and plateau time above 300 Hounsfield units (HU) were analysed. Results: Intra-individual comparison revealed no statistically significant differences in contrast enhancement between the iopromide 300 and iodixanol 320 in the pulmonary artery and the aorta (620 vs 552 HU; P = 0.13). There was no significant difference between the two CM in the plateau time at the pulmonary artery and the aorta (P = 0.75 and P = 0.24, respectively). Aortic peak time was significantly earlier with iopromide 300 than with iodixanol 320 (P = 0.004). Conclusions: Low-osmolar monomeric and iso-osmolar dimeric CM provide a similar and suitable vascular contrast enhancement.
引用
收藏
页码:170 / 175
页数:6
相关论文
共 19 条
  • [1] Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor-to-liver contrast at multi-detector row CT
    Awai, K
    Inoue, M
    Yagyu, Y
    Watanabe, M
    Sano, T
    Nin, S
    Koike, R
    Nishimura, Y
    Yamashita, Y
    [J]. RADIOLOGY, 2004, 233 (03) : 682 - 688
  • [2] Intraindividual comparison of contrast media concentrations for combined abdominal and thoracic MDCT
    Behrendt, Florian F.
    Mahnken, Andreas H.
    Stanzel, Sven
    Seidensticker, Peter
    Jost, Edgar
    Guenther, Rolf W.
    Muehlenbruch, Georg
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (01) : 145 - 150
  • [3] Intra-individual comparison of different contrast media concentrations (300 mg, 370 mg and 400 mg iodine) in MDCT
    Behrendt, Florian F.
    Pietsch, Hubertus
    Jost, Gregor
    Sieber, Martin A.
    Keil, Sebastian
    Plumhans, Cedric
    Seidensticker, Peter
    Guenther, Rolf W.
    Mahnken, Andreas H.
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (07) : 1644 - 1650
  • [4] Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: Influence of time resolution, maximal signal drop and signal-to-noise
    Benner, T
    Heiland, S
    Erb, G
    Forsting, M
    Sartor, K
    [J]. MAGNETIC RESONANCE IMAGING, 1997, 15 (03) : 307 - 317
  • [5] High iodine concentration contrast material for noninvasive multislice computed tomography coronary angiography - Iopromide 370 versus iomeprol 400
    Cademartiri, F
    de Monye, C
    Pugliese, F
    Mollet, NR
    Runza, G
    van der Lugt, A
    Midiri, M
    de Feyter, PJ
    Lagalla, R
    Krestin, GP
    [J]. INVESTIGATIVE RADIOLOGY, 2006, 41 (03) : 349 - 353
  • [6] HEPATIC CT ENHANCEMENT - COMPARISON OF IONIC AND NONIONIC CONTRAST AGENTS IN THE SAME PATIENTS
    CHAMBERS, TP
    BARON, RL
    LUSH, RM
    DODD, GD
    MILLER, WJ
    [J]. RADIOLOGY, 1994, 190 (03) : 721 - 725
  • [7] HEPATIC CT ENHANCEMENT - A METHOD TO DEMONSTRATE REPRODUCIBILITY
    CHAMBERS, TP
    BARON, RL
    LUSH, RM
    DODD, GD
    MILLER, WJ
    CONFER, SR
    [J]. RADIOLOGY, 1993, 188 (03) : 627 - 631
  • [8] Nephrotoxicity of Iso-osmolar Iodixanol Compared with Nonionic Low-osmolar Contrast Media: Meta-analysis of Randomized Controlled Trials
    Heinrich, Marc C.
    Haeberle, Lothar
    Mueller, Volker
    Bautz, Werner
    Uder, Michael
    [J]. RADIOLOGY, 2009, 250 (01) : 68 - 86
  • [9] Influence of osmolarity of contrast medium and saline flush on computed tomography angiography: Comparison of monomeric and dimeric iodinated contrast media with different iodine concentrations at an identical iodine delivery rate
    Kishimoto, Miori
    Doi, Shoko
    Shimizu, Junichiro
    Lee, Ki-Ja
    Iwasaki, Toshiroh
    Miyake, Yoh-Ichi
    Yamada, Kazutaka
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2010, 76 (01) : 135 - 139
  • [10] Renal failure in 57 925 patients undergoing coronary procedures using iso-osmolar or low-osmolar contrast media
    Liss, P.
    Persson, P. B.
    Hansell, P.
    Lagerqvist, B.
    [J]. KIDNEY INTERNATIONAL, 2006, 70 (10) : 1811 - 1817