Effects of Bolt Slip on the Dynamic Characteristics of Transmission Tower-line System

被引:0
作者
Zhao, Xiu-zhen [1 ]
Chen, Hai-bo [1 ]
Ye, Min [1 ]
Huang, Ying-qing [1 ]
机构
[1] Univ Sci & Technol China, Dept Modern Mech, CAS Key Lab Mech Behav & Design Mat, Hefei 230027, Anhui, Peoples R China
来源
2ND INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY AND ENVIRONMENTAL ENGINEERING (SEEE 2016) | 2016年
关键词
Bolt slippage; Transmission tower-line system; Dynamic characteristics;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Bolt slippage has significant influences on the mechanical behavior of transmission towers. In this paper, an improved finite element model named as Slip Beam model was established considering bolt slippage and load eccentricity. Traditional models including Rigid and Beam-Truss models were also studied based on ANSYS. Dynamic characteristics of three models were calculated and compared. It is found that the simulation results of the slip model agree well with the test data in contrast with the other two models. To investigate the effects of bolt slip on the dynamic characteristic of transmission tower-line systems, tower-line coupling systems corresponding to the single tower models were developed for the first time. Some valuable conclusions are presented.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Advances in mechanical models of transmission tower-line systems
    Chen B.
    Song X.-X.
    Wu J.-B.
    Gongcheng Lixue/Engineering Mechanics, 2021, 38 (05): : 1 - 21
  • [22] Fundamental Theoretical Study on Antiseismic and Wind-Proof of Transmission Tower-Line System
    Li, H. N.
    Bai, H. F.
    Ren, Y. M.
    PROCEEDINGS OF THE 2ND INTERNATIONAL FORUM ON ADVANCES IN STRUCTURAL ENGINEERING - 2008: STRUCTURAL DISASTER PREVENTION, MONITORING AND CONTROL, 2008, : 100 - +
  • [23] STUDY ON THE SEISMIC MITIGATION PERFORMANCE OF PARTICLE DAMPERS APPLIED TO TRANSMISSION TOWER-LINE SYSTEM
    Lu Z.
    Shen Y.-L.
    Tan Q.-H.
    Rong K.-J.
    Tian L.
    Gongcheng Lixue/Engineering Mechanics, 2024, 41 (07): : 9 - 18
  • [25] Response of a transmission tower-line system at a canyon site to spatially varying ground motions
    Hong-nan Li
    Feng-long Bai
    Li Tian
    Hong Hao
    Journal of Zhejiang University-SCIENCE A, 2011, 12 : 103 - 120
  • [26] Wind hazard reliability assessment of a transmission tower-line system incorporating progressive collapse
    Du, Wen-Long
    Fu, Xing
    Shao, Shuai
    Li, Gang
    Li, Hong-Nan
    Yang, Feng-Li
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2025, 257
  • [27] Response of a transmission tower-line system at a canyon site to spatially varying ground motions
    Li, Hong-nan
    Bai, Feng-long
    Tian, Li
    Hao, Hong
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2011, 12 (02): : 103 - 120
  • [28] Seismic response and collapse analysis of a transmission tower-line system considering uncertainty factors
    Fu, Zhaoyang
    Tian, Li
    Liu, Juncai
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2022, 189
  • [29] Seismic response of transmission tower-line system under coupled horizontal and tilt ground motion
    Wei W.
    Yuan C.
    Wang H.
    Hu Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 (06): : 79 - 88
  • [30] Probabilistic capacity assessment of single circuit transmission tower-line system subjected to strong winds
    Li, Xuan
    Zhang, Wei
    Niu, Huawei
    Wu, Zheng Yi
    ENGINEERING STRUCTURES, 2018, 175 : 517 - 530