Heterogeneity in the left atrial wall thickness contributes to atrial fibrillation recurrence after catheter ablation

被引:21
|
作者
Nakatani, Yosuke [1 ]
Sakamoto, Tamotsu [1 ]
Yamaguchi, Yoshiaki [1 ]
Tsujino, Yasushi [1 ]
Kataoka, Naoya [1 ]
Kinugawa, Koichiro [1 ]
机构
[1] Univ Toyama, Dept Internal Med 2, 2630 Sugitani, Toyama 9300194, Japan
关键词
Atrial fibrillation; Atrial arrhythmia; Catheter ablation; Atrial wall thickness; Pulmonary vein isolation; TACHYCARDIA; MECHANISM; SUBSTRATE; DURATION; EFFICACY; IMPACT; MODEL;
D O I
10.1007/s00380-018-1200-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Influence of left atrial wall thickness on outcome of catheter ablation for atrial fibrillation (AF) is unclear. Overall, 213 patients with AF (128 paroxysmal and 85 persistent) received ablation. We measured the wall thickness of 16 and 19 areas in the pulmonary vein antrum (PVWT) and left atrial body (LAWT), respectively. Coefficient of variation of wall thickness (CV-WT) was calculated to assess heterogeneity in the left atrial wall thickness. In patients with paroxysmal AF, maximum PVWT, mean PVWT, maximum LAWT, and CV-WT were higher in AF recurrent group than in AF-free group (maximum PVWT, 2.85 +/- 0.52 vs. 2.50 +/- 0.45mm, P=0.003; mean PVWT, 1.59 +/- 0.13 vs. 1.50 +/- 0.15mm, P=0.018; maximum LAWT, 3.85 +/- 0.77 vs. 3.41 +/- 0.61mm, P=0.005; CV-WT, 0.34 +/- 0.06 vs. 0.32 +/- 0.05, P=0.039). In patients with persistent AF, maximum PVWT, mean PVWT, maximum LAWT, mean LAWT, and CV-WT were higher in the AF-recurrent group than in the AF-free group (maximum PVWT, 2.52 +/- 0.36 vs. 2.31 +/- 0.36mm, P=0.031; mean PVWT, 1.53 +/- 0.12 vs. 1.45 +/- 0.14mm, P=0.036; maximum LAWT, 3.68 +/- 0.75 vs. 3.11 +/- 0.50mm, P<0.001; mean LAWT, 2.34 +/- 0.35 vs. 2.13 +/- 0.21mm, P=0.002; CV-WT, 0.35 +/- 0.06 vs. 0.31 +/- 0.05, P=0.005). Thick and heterogeneous left atrial wall contributes to AF recurrence after ablation.
引用
收藏
页码:1549 / 1558
页数:10
相关论文
共 50 条
  • [1] Heterogeneity in the left atrial wall thickness contributes to atrial fibrillation recurrence after catheter ablation
    Yosuke Nakatani
    Tamotsu Sakamoto
    Yoshiaki Yamaguchi
    Yasushi Tsujino
    Naoya Kataoka
    Koichiro Kinugawa
    Heart and Vessels, 2018, 33 : 1549 - 1558
  • [2] Impacts of the body size on the left atrial wall thickness and atrial fibrillation recurrence after catheter ablation
    Yosuke Nakatani
    Tamotsu Sakamoto
    Yoshiaki Yamaguchi
    Yasushi Tsujino
    Naoya Kataoka
    Kunihiro Nishida
    Koichi Mizumaki
    Koichiro Kinugawa
    Heart and Vessels, 2019, 34 : 1351 - 1359
  • [3] Impacts of the body size on the left atrial wall thickness and atrial fibrillation recurrence after catheter ablation
    Nakatani, Yosuke
    Sakamoto, Tamotsu
    Yamaguchi, Yoshiaki
    Tsujino, Yasushi
    Kataoka, Naoya
    Nishida, Kunihiro
    Mizumaki, Koichi
    Kinugawa, Koichiro
    HEART AND VESSELS, 2019, 34 (08) : 1351 - 1359
  • [4] Association of left atrial wall thickness with recurrence after cryoballoon ablation of paroxysmal atrial fibrillation
    Bai, Yixuan
    Jia, Ruikun
    Wang, Xinmeng
    Chan, Juan
    Cui, Kaijun
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (03) : 657 - 667
  • [5] Left atrial wall thickness and outcomes of catheter ablation for atrial fibrillation in patients with hypertrophic cardiomyopathy
    Hayashi, Hiroshi
    Hayashi, Meiso
    Miyauchi, Yasushi
    Takahashi, Kenta
    Uetake, Shunsuke
    Tsuboi, Ippei
    Yodogawa, Kenji
    Iwasaki, Yu-Ki
    Shimizu, Wataru
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 40 (02) : 153 - 160
  • [6] Left Atrial Wall Thickness Estimated by Cardiac CT: Implications for Catheter Ablation of Atrial Fibrillation
    Cunha, Pedro Silva
    Laranjo, Sergio
    Monteiro, Sofia
    Almeida, Ines Gracio
    Mendonca, Tiago
    Fontes, Iladia
    Ferreira, Rui Cruz
    Almeida, Ana G.
    Didenko, Maxim
    Oliveira, Mario Martins
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (18)
  • [7] Association of left atrial wall thickness with recurrence after cryoballoon ablation of paroxysmal atrial fibrillation
    Yixuan Bai
    Ruikun Jia
    Xinmeng Wang
    Juan Chan
    Kaijun Cui
    Journal of Interventional Cardiac Electrophysiology, 2024, 67 : 657 - 667
  • [8] Left atrial appendage size is a marker of atrial fibrillation recurrence after radiofrequency catheter ablation in patients with persistent atrial fibrillation
    Simon, Judit
    El Mahdiui, Mohammed
    Smit, Jeff M.
    Szaraz, Lili
    van Rosendael, Alexander R.
    Herczeg, Szilvia
    Zsarnoczay, Emese
    Nagy, Aniko Ilona
    Kolossvary, Marton
    Szilveszter, Balint
    Szegedi, Nandor
    Nagy, Klaudia Vivien
    Tahin, Tamas
    Geller, Laszlo
    van der Geest, Rob J.
    Bax, Jeroen J.
    Maurovich-Horvat, Pal
    Merkely, Bela
    CLINICAL CARDIOLOGY, 2022, 45 (03) : 273 - 281
  • [9] Association of left atrial enlargement and increased left ventricular wall thickness with arrhythmia recurrence after cryoballoon ablation for atrial fibrillation
    Warminski, Grzegorz
    Urbanek, Piotr
    Orczykowski, Michal
    Bodalski, Robert
    Kalinczuk, Lukasz
    Zielinski, Kamil
    Mintz, Gary S.
    Jedynak, Zbigniew
    Hasiec, Andrzej
    Zakrzewska-Koperska, Joanna
    Michalowska, Ilona
    Kowalik, Ilona
    Lazarczyk, Hubert
    Sterlinski, Maciej
    Bilinska, Maria
    Plawiak, Pawel
    Szumowski, Lukasz
    KARDIOLOGIA POLSKA, 2022, 80 (11) : 1126 - 1133
  • [10] Left atrial shape predicts recurrence after atrial fibrillation catheter ablation
    Bieging, Erik T.
    Morris, Alan
    Wilson, Brent D.
    McGann, Christopher J.
    Marrouche, Nassir F.
    Cates, Joshua
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (07) : 966 - 972