Asynchrony and cyclic variability in pressure support noninvasive ventilation

被引:18
作者
Achour, Linda
Letellier, Christophe [1 ]
Cuvelier, Antoine
Verin, Eric
Muir, Jean-Francois
机构
[1] Univ Rouen, CORIA, UMR 6614, Av Univ BP 12, F-76801 St Etienne, France
[2] Univ Rouen, Hop Bois Guillaume, Serv Pneumol & Soins Intensifs, F-76821 Mont St Aignan, France
[3] Univ Rouen Ctr Hosp, Hop Charles Nicolle, Grp Physiol Digest Urinaire Resp & Sport, F-76821 Mont St Aignan, France
[4] Univ Rouen, UPRES EA 3830, IFR MP23, F-76821 Mont St Aignan, France
关键词
noninvasive ventilation asynchrony; phase portrait and first-return maps; dynamical analysis;
D O I
10.1016/j.compbiomed.2006.12.005
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Noninvasive mechanical ventilation is an effective procedure to manage patients with acute or chronic respiratory failure. Most ventilators act as flow generators that assist spontaneous respiratory cycles by delivering inspiratory and expiratory pressures. This allows the patient to improve alveolar ventilation and subsequent pulmonary gas exchanges. The interaction between the patient and his ventilator are therefore crucial for tolerance and acceptability and part of this interaction is the facility to trigger the ventilator at the beginning of the inspiration. This is directly related to patients' discomfort which is not quantified today. Phase portraits reconstructed from the airflow and first-return maps built on the total breath duration were used to investigate the quality of the patient-ventilator interaction. Phase synchronization can be identified from phase portrait and the breath-to-breath variability is well characterized by return maps. This paper is a first step in the direction of automatically estimating the comfort from measurements and not from a necessarily subjective answer given by the patient. These tools could be helpful for the physicians to set the ventilator parameters. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1308 / 1320
页数:13
相关论文
共 37 条
[1]   APPLICATION OF ABDOMINAL PRESSURE FOR ARTIFICIAL RESPIRATION [J].
ADAMSON, JP ;
STEIN, JD .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1959, 169 (14) :1613-1617
[2]   Nonlinear multivariable modeling and analysis of sleep apnea time series [J].
Aguirre, LA ;
Barros, VC ;
Souza, AVP .
COMPUTERS IN BIOLOGY AND MEDICINE, 1999, 29 (03) :207-228
[3]   IS THE NORMAL HEART A PERIODIC OSCILLATOR [J].
BABLOYANTZ, A ;
DESTEXHE, A .
BIOLOGICAL CYBERNETICS, 1988, 58 (03) :203-211
[4]  
BERGER AJ, 1998, TXB RESP MED CONTROL, P149
[5]   Breathing pattern variability: a weaning predictor in postoperative patients recovering from systemic inflammatory response syndrome [J].
Bien, MY ;
Hseu, SS ;
Yien, HW ;
Kuo, BIT ;
Lin, YT ;
Wang, JH ;
Kou, YR .
INTENSIVE CARE MEDICINE, 2004, 30 (02) :241-247
[6]   Dyspnea and decreased variability of breathing in patents with restrictive lung disease [J].
Brack, T ;
Jubran, A ;
Tobin, MJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2002, 165 (09) :1260-1264
[7]  
Bruce E. N, 1995, Regulation of breathing, P285
[8]   An apparatus for the prolonged administration of artificial respiration I A design for adults and children [J].
Drinker, P ;
Shaw, LA .
JOURNAL OF CLINICAL INVESTIGATION, 1929, 7 (02) :229-247
[9]   In vivo physiologic comparison of two ventilators used for domiciliary ventilation in children with cystic fibrosis [J].
Fauroux, B ;
Pigeot, J ;
Polkey, MI ;
Isabey, D ;
Clément, A ;
Lofaso, F .
CRITICAL CARE MEDICINE, 2001, 29 (11) :2097-2105
[10]  
Georgopoulos D B, 1997, Monaldi Arch Chest Dis, V52, P253