BACKGROUND: Granulocyte antibodies have been implicated in allo- and autoimmune neutropenia and in transfusion reactions. STUDY DESIGN AND METHODS: Fifty-one sera from suspected alloimmune neutropenia or transfusion-related acute lung injury (TRALI) and 40 sera from suspected autoimmune neutropenia were tested for granulocyte antibodies using LABScreen MULTI (One Lambda, Inc.), compared with classical tests (flow cytometry [FC] and granulocyte agglutination [GAT] followed by monoclonal antibody-specific immobilization of granulocyte antigens [MAIGA]). RESULTS: In alloimmune situations, 48 sera were concordant (94%), two sera positive for HNA with LABScreen MULTI were negative by FC/GAT and/or MAIGA, and one serum sample negative for HNA with LABScreen MULTI was positive by classical tests. In autoimmune neutropenia, 30 sera were concordant (75%), four sera positive for HNA with LABScreen MULTI were negative by FC/GAT and/or MAIGA, and six sera negative for HNA with LABScreen MULTI were positive by FC/GAT and/or MAIGA. For detection of autoantibodies, the LABScreen MULTI was less concordant. However, with the exception of one case, the discrepancies were observed in sera that did not show a clear specificity. CONCLUSIONS: LABScreen MULTI correlated well with our classical methods for HNA-1 and HNA-2a antibody screening. It can be used for screening blood donors or patients suspected of TRALI, but GAT is still needed for HNA-3a antibody screening.
引用
收藏
页码:2643 / 2648
页数:6
相关论文
共 16 条
[1]  
[Anonymous], 2008, [No title captured], P68
[2]   Recommendations of the ISBT Working Party on Granulocyte Immunobiology for leucocyte antibody screening in the investigation and prevention of antibody-mediated transfusion-related acute lung injury [J].
Bierling, P. ;
Bux, J. ;
Curtis, B. ;
Flesch, B. ;
Fung, I. ;
Lucas, G. ;
Macek, M. ;
Muniz-Diaz, E. ;
Porcelijn, I. ;
Reil, A. ;
Sachs, U. ;
Schuller, R. ;
Tsuno, N. ;
Uhrynowska, M. ;
Urbaniak, S. ;
Valentin, N. ;
Wikman, A. ;
Zupanska, B. .
VOX SANGUINIS, 2009, 96 (03) :266-269
[3]   Human neutrophil alloantigens [J].
Bux, J. .
VOX SANGUINIS, 2008, 94 (04) :277-285
[4]   Report on the Second International Granulocyte Serology Workshop [J].
Bux, J ;
Chapman, J .
TRANSFUSION, 1997, 37 (09) :977-983
[5]   ANALYSIS OF GRANULOCYTE-REACTIVE ANTIBODIES USING AN IMMUNOASSAY BASED UPON MONOCLONAL-ANTIBODY-SPECIFIC IMMOBILIZATION OF GRANULOCYTE ANTIGENS [J].
BUX, J ;
KOBER, B ;
KIEFEL, V ;
MUELLERECKHARDT, C .
TRANSFUSION MEDICINE, 1993, 3 (02) :157-162
[6]   Alloimmune neonatal neutropenia linked to anti-HNA-4a [J].
Fung, YL ;
Pitcher, LA ;
Willett, JE ;
Reed, C ;
Mison, L ;
Bux, J ;
Eiber, G ;
Minchinton, RM .
TRANSFUSION MEDICINE, 2003, 13 (01) :49-52
[7]   Characterization of the human neutrophil alloantigen-3a [J].
Greinacher, Andreas ;
Wesche, Jan ;
Hammer, Elke ;
Fuerll, Birgitt ;
Voelker, Uwe ;
Reil, Angelika ;
Bux, Juergen .
NATURE MEDICINE, 2010, 16 (01) :45-48
[8]  
HARTMAN KR, 1991, BLOOD, V78, P1096
[9]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[10]   A COMPARISON OF METHODS FOR DETECTING LEUKOCYTE ANTIBODIES IN AUTOIMMUNE NEUTROPENIA [J].
MCCULLOUGH, J ;
CLAY, ME ;
PRIEST, JR ;
JENSEN, NJ ;
LAU, S ;
NOREEN, HJ ;
KRIVIT, W ;
LALEZARI, P .
TRANSFUSION, 1981, 21 (05) :483-492