Comparison of cone-beam computed tomography with multislice computed tomography in detection of small osseous condylar defects

被引:2
作者
Jones, Elizabeth M. [1 ]
Papio, Melissa [1 ]
Tee, Boon Ching [2 ]
Beck, Frank M. [2 ]
Fields, Henry W. [1 ]
Sun, Zongyang [1 ]
机构
[1] Ohio State Univ, Coll Dent, Div Orthodont, Columbus, OH 43210 USA
[2] Ohio State Univ, Coll Dent, Div Biosci, Columbus, OH 43210 USA
关键词
TEMPOROMANDIBULAR-JOINT; MANDIBULAR CONDYLE; DENTAL USE; CT; DISORDERS; ACCURACY; SYMPTOMS; RELIABILITY; PREVALENCE; RESOLUTION;
D O I
10.1016/j.ajodo.2015.12.019
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Previous studies have indicated that orthodontic-grade cone-beam computed tomography (CBCT) images are limited when displaying small defects at the mandibular condyles for diagnosis. In this study, we investigated whether this limitation was inherent to CBCT by comparing CBCT with multislice computed tomography (CT), and whether image segmentation and color mapping could overcome this limitation. Methods: Nine fresh pig heads (18 condyles, 36 medial and lateral condylar regions) were used. Small osseous defects (diameter and depth, 1.5 mm) were created at the medial and lateral regions of the condyles shown by gutta percha markers. After the overlying soft tissues were restored, the pig heads underwent orthodontic-grade CBCT scans (0.4-mm voxel size; i-CAT; Imaging Sciences International, Hatfield, Pa) and medical-grade CT scans (0.625-mm voxel size; LightSpeed; GE, Little Chalfont, Buckinghamshire, United Kingdom). Subsequently, 2 calibrated and blinded raters diagnosed the defect numbers in each condylar region from CBCT and CT images using Dolphin 3D software (Patterson Supply, St Paul, Minn) without image segmentation, and then 1 week later with the proprietary image segmentation and color mapping tools of Dolphin 3D. Condylar polyvinyl siloxane impressions were collected and evaluated by the same raters to obtain physical diagnoses. Rediagnoses were made on randomly selected subsamples to assess reliability. Using the physical diagnoses as references, the accuracy of imaging diagnosis was assessed and statistically compared among the varied imaging and analysis methods. Results: Image diagnoses of all imaging and analysis methods showed good or excellent intrarater and interrater reliability values, except for those of the segmented CBCT images, which were substantially lower. The numbers of overdiagnoses and underdiagnoses per condylar region were not significantly different among the varied imaging and analysismethods (Wilcoxon tests, P > 0.05), but classification functions demonstrated substantially lower sensitivity and accuracy with CBCT than with CT. Logistic regression also showed that CT had a significantly higher probability (odds ratio, 2.4) than CBCT in reaching the correct diagnosis, whereas use of the image segmentation and color mapping tool proprietary to Dolphin 3D did not improve the diagnostic accuracy from CBCT images. Conclusions: Even at a lower voxel size than medical CT images, orthodontic-grade CBCT images of mandibular condyles may be inherently less reliable and less accurate for the diagnosis of small condylar defects.
引用
收藏
页码:130 / 139
页数:10
相关论文
共 30 条
[1]   Research diagnostic criteria for temporomandibular disorders (RDC/TMD): development of image analysis criteria and examiner reliability for image analysis [J].
Ahmad, Mansur ;
Hollender, Lars ;
Anderson, Quentin ;
Kartha, Krishnan ;
Ohrbach, Richard ;
Truelove, Edmond L. ;
John, Mike T. ;
Schiffman, Eric L. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (06) :844-860
[2]   Image distortion and spatial resolution of a commercially available cone-beam computed tomography machine [J].
Ballrick, John W. ;
Palomo, J. Martin ;
Ruch, Edward ;
Amberman, B. Douglas ;
Hans, Mark G. .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (04) :573-582
[3]   Validity of single- and multislice CT for assessment of mandibular condyle lesions [J].
Cara, A. C. B. ;
Gaia, B. F. ;
Perrella, A. ;
Oliveira, J. X. O. ;
Lopes, P. M. L. ;
Cavalcanti, M. G. P. .
DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (01) :24-27
[4]  
Carlsson GE, 1994, TEMPOROMANDIBULAR JO
[5]   Quantification of condylar resorption in temporomandibular joint osteoarthritis [J].
Cevidanes, L. H. S. ;
Hajati, A. -K. ;
Paniagua, B. ;
Lim, P. F. ;
Walker, D. G. ;
Palconet, G. ;
Nackley, A. G. ;
Styner, M. ;
Ludlow, J. B. ;
Zhu, H. ;
Phillips, C. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2010, 110 (01) :110-117
[6]   MSCT versus CBCT: evaluation of high-resolution acquisition modes for dento-maxillary and skull-base imaging [J].
Dillenseger, Jean-Philippe ;
Matern, Jean-Francois ;
Gros, Catherine-Isabelle ;
Bornert, Fabien ;
Goetz, Christian ;
Le Minor, Jean-Marie ;
Constantinesco, Andre ;
Choquet, Philippe .
EUROPEAN RADIOLOGY, 2015, 25 (02) :505-515
[7]   Evaluation of bone changes in the temporomandibular joint using cone beam CT [J].
dos Anjos Pontual, M. L. ;
Freire, J. S. L. ;
Barbosa, J. M. N. ;
Frazao, M. A. G. ;
dos Anjos Pontual, A. .
DENTOMAXILLOFACIAL RADIOLOGY, 2012, 41 (01) :24-29
[8]   Clinical recommendations regarding use of cone beam computed tomography in orthodontics. Position statement by the American Academy of Oral and Maxillofacial Radiology [J].
Evans, Carla A. ;
Scarfe, William C. ;
Ahmad, Mansur ;
Cevidanes, Lucia H. S. ;
Ludlow, John B. ;
Palomo, J. Martin ;
Simmons, Kirt E. ;
White, Stuart C. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 116 (02) :238-257
[9]  
Gesch D, 2004, QUINTESSENCE INT, V35, P143
[10]   Comparison of image validity between cone beam computed tomography for dental use and multidetector row helical computed tomography [J].
Hashimoto, K. ;
Kawashima, S. ;
Kameoka, S. ;
Akiyama, Y. ;
Honjoya, T. ;
Ejima, K. ;
Sawada, K. .
DENTOMAXILLOFACIAL RADIOLOGY, 2007, 36 (08) :465-471