Ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) and UPLC/MSE analysis of RNA oligonucleotides

被引:31
|
作者
Ivleva, Vera B. [1 ]
Yu, Ying-Qing [1 ]
Gilar, Martin [1 ]
机构
[1] Waters Corp, Milford, MA 01757 USA
关键词
COLLISION-INDUCED DISSOCIATION; OFF-RESONANCE IRRADIATION; NUCLEIC-ACIDS; THERAPEUTIC OLIGONUCLEOTIDES; QUANTITATIVE-ANALYSIS; FRAGMENTATION; PURIFICATION; MS; INTERFERENCE; MECHANISMS;
D O I
10.1002/rcm.4683
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Fast and efficient ultra-performance liquid chromatography/tandem mass spectrometry (UPLC/MS/MS) analysis of short interfering RNA oligonucleotides was used for identity confirmation of the target sequence-related impurities. Multiple truncated oligonucleotides and metabolites were identified based on the accurate mass, and their presumed sequence was confirmed by MS/MS and MSE (alternating low and elevated collision energy scanning modes) methods. Based on the resulting fragmentation of native and chemically modified oligonucleotides, it was found that the MSE technique is as efficient as the traditional MS/MS method, yet MSE is more general, faster, and capable of producing higher signal intensities of fragment ions. Fragmentation patterns of modified oligonucleotides were investigated using RNA 2'-ribose substitutions, phosphorothioate RNA, and LNA modifications. The developed sequence confirmation method that uses the MSC approach was applied to the analysis of in vitro hydrolyzed RNA oligonucleotide. The target RNA and metabolites, including the structural isomers, were resolved by UPLC, and their identity was confirmed by MSE. Simultaneous RNA truncations from both termini were observed. The UPLC quadrupole time-of-flight (QTOF) MS/MS and MSE methods were shown to be an effective tool for the analysis and sequence confirmation of complex oligonucleotide mixtures. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:2631 / 2640
页数:10
相关论文
共 50 条
  • [21] Analysis of triazine herbicides in water using solid phase extraction followed by ultra-performance liquid chromatography with tandem mass detection (UPLC-MS/MS)
    Drozdzynski, Dariusz
    Folkman, Wojciech
    CHEMIA ANALITYCZNA, 2008, 53 (03): : 391 - 400
  • [22] UPLC: Ultra-performance liquid chromatography
    1600, AOAC International (88):
  • [23] UPLC: Ultra-performance liquid chromatography
    Sherma, J
    Larkin, JD
    Larkin, FH
    JOURNAL OF AOAC INTERNATIONAL, 2005, 88 (03) : 63A - 67A
  • [24] Simultaneous determination of five local anesthesics in plasma by Ultra Performance Liquid Chromatography-tandem Mass Spectrometry (UPLC-MS/MS)
    Canal-Raflin, M.
    Bernard, O.
    Martinez, B.
    Tauzin, P.
    Stzark, F.
    Molimard, M.
    Moore, N.
    FUNDAMENTAL & CLINICAL PHARMACOLOGY, 2010, 24 : 55 - 55
  • [25] Validation of an automated clotting assay for monitoring plasma argatroban levels in comparison with a novel ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method
    Snyder, M. L.
    Winkler, A. M.
    Brierre, F.
    Molinaro, R. J.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 978 - 978
  • [26] Simultaneous Determination of Preservatives, Artificial Sweeteners, and Synthetic Dyes in Kimchi by Ultra-Performance Liquid Chromatography Electrospray Ionization Tandem Mass Spectrometry (UPLC-ESI-MS/MS)
    Lee, Hee Min
    Yang, Ji-Su
    Lee, Hae-Won
    Hwang, In Min
    Hwang, Ye Seul
    You, Su-Yeon
    Ha, Ji-Hyoung
    Kim, Sung Hyun
    ANALYTICAL LETTERS, 2019, 52 (16) : 2472 - 2483
  • [27] Toxicokinetics and Tissue Distribution of the Hepatotoxic Triterpenoid Saponin Pterocephin A in Rats Using the Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS) Method
    Xiong, Yiran
    Dong, Zhaoyue
    Zhou, Hongxu
    Mao, Jingxin
    Zeng, Lingjiang
    Jiang, Yunbin
    Meng, Fancheng
    Liao, Zhihua
    Chen, Min
    MOLECULES, 2024, 29 (21):
  • [28] Comparison of a novel ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method with the activated partial thromboplastin time (aPTT) and prothrombin time (PT)
    Winkler, A. M.
    Synder, M. L.
    Duncan, A.
    Molinaro, R. J.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 363 - 363
  • [29] A simple validated multi-analyte method for detecting drugs in oral fluid by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS)
    Zheng, Yufang
    Sparve, Erik
    Bergstrom, Mats
    DRUG TESTING AND ANALYSIS, 2018, 10 (06) : 1001 - 1008
  • [30] Characterization of the Source of Heroin by Ultra-High-Performance Liquid Chromatography with Tandem Mass Spectrometry (UPLC-MS/MS) and Principal Component Analysis (PCA)
    Liu, Shan
    Chen, Yuemeng
    Wang, Fang
    Bai, Song
    ANALYTICAL LETTERS, 2025, 58 (05) : 702 - 713