Theoretical analysis of ejector refrigeration system performance under overall modes

被引:124
作者
Chen, Weixiong [1 ]
Shi, Chaoyin [1 ]
Zhang, Shuangping [1 ]
Chen, Huiqiang [1 ]
Chong, Daotong [1 ]
Yan, Junjie [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
基金
中国博士后科学基金; 中国国家自然科学基金;
关键词
Ejector refrigeration; Theoretical model; Real gas property; Sub-critical mode; Refrigerants; CYCLE;
D O I
10.1016/j.apenergy.2016.01.103
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The ejector refrigeration integrated in the air-conditioning system is a promising technology, because it could be driven by the low grade energy. In the present study, a theoretical calculation based on the real gas property is put forward to estimate the ejector refrigeration system performance under overall modes (critical/sub-critical modes). The experimental data from literature are applied to validate the proposed model. The findings show that the proposed model has higher accuracy compared to the model using the ideal gas law, especially when the ejector operates at sub-critical mode. Then, the performances of the ejector refrigeration circle using different refrigerants are analyzed. R290 and R134a are selected as typical refrigerants by considering the aspects of COP, environmental impact, safety and economy. Finally, the ejector refrigeration performance is investigated under variable operation conditions with R290 and R134a as refrigerants. The results show that the R290 ejector circle has higher COP under critical mode and could operate at low evaporator temperature. However, the performance would decrease rapidly at high condenser temperature. The performance of R134a ejector circle is the opposite, with relatively lower COP, and higher COP at high condenser temperature compared to R290. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2074 / 2084
页数:11
相关论文
共 22 条
[1]   Review on solar-driven ejector refrigeration technologies [J].
Abdulateef, J. M. ;
Sopian, K. ;
Alghoul, M. A. ;
Sulaiman, M. Y. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (6-7) :1338-1349
[2]   Experimental investigation of an ejector refrigerator: Effect of mixing chamber geometry on system performance [J].
Aphornratana, S ;
Chungpaibulpatana, S ;
Srikhirin, P .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2001, 25 (05) :397-411
[3]  
Calm J.M., 2007, HPAC Eng (Heat Pip Air Cond), P50
[4]   A general model for evaluation of vapor ejectors performance for application in refrigeration [J].
Cardemil, Jose M. ;
Colle, Sergio .
ENERGY CONVERSION AND MANAGEMENT, 2012, 64 :79-86
[5]   Conventional and advanced exergy analysis of an ejector refrigeration system [J].
Chen, Jianyong ;
Havtun, Hans ;
Palm, Bjorn .
APPLIED ENERGY, 2015, 144 :139-151
[6]   Screening of working fluids for the ejector refrigeration system [J].
Chen, Jianyong ;
Hautun, Hans ;
Palm, Bjorn .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2014, 47 :1-14
[7]   A 1D model to predict ejector performance at critical and sub-critical operational regimes [J].
Chen, WeiXiong ;
Liu, Ming ;
Chong, DaoTong ;
Yan, JunJie ;
Little, Adrienne Blair ;
Bartosiewicz, Yann .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (06) :1750-1761
[8]   Suitability of coupling a solar powered ejection cycle with a vapour compression refrigerating machine [J].
Chesi, Andrea ;
Ferrara, Giovanni ;
Ferrari, Lorenzo ;
Tarani, Fabio .
APPLIED ENERGY, 2012, 97 :374-383
[9]   Ejectors: applications in refrigeration technology [J].
Chunnanond, K ;
Aphornratana, S .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2004, 8 (02) :129-155
[10]   A one dimensional model for the determination of an ejector entrainment ratio [J].
Garcia del Valle, Javier ;
Saiz Jabardo, Jose M. ;
Castro Ruiz, Francisco ;
Jose Alonso, Julio San .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (04) :772-784