Atypical rounded atelectasis: diagnosis and management based on results of F-18FDG positron emission tomography

被引:2
作者
Ludeman, N
Elicker, BM
Reddy, GP
Webb, WR
Leung, JWT
Gotway, MB
机构
[1] Univ Calif San Francisco, Dept Radiol, Div Thorac Imaging, San Francisco, CA 94143 USA
[2] Yale Univ, Sch Med, Dept Radiol, New Haven, CT 06510 USA
关键词
rounded atelectasis; positron emission tomography; asbestos-related pleural disease; pulmonary nodule;
D O I
10.1097/01.rlu.0000182265.17985.d0
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A 58-year-old man presented with bilateral focal pulmonary opacities in the setting of asbestos-related pleural disease. CT features of the opacities were insufficiently characteristic to diagnose rounded atelectasis. Needle biopsy failed to exclude malignancy. FDG-PET imaging showed minimal metabolic activity within these opacities, allowing conservative management, as opposed to thoracotomy. Although FDG-PET findings of rounded atelectasis are known, little is known about FDG-PET results in patients with atypical rounded atelectasis on CT. FDG-PET is a useful test in the setting of asbestos-related pleural disease and rounded atelectasis, and may obviate need for more invasive and expensive diagnostic procedures. Copyright © 2005 by Lippincott Williams & Wilkins.
引用
收藏
页码:734 / 735
页数:2
相关论文
共 15 条
[1]   COMPUTED-TOMOGRAPHY OF FOLDED LUNG [J].
CARVALHO, PM ;
CARR, DH .
CLINICAL RADIOLOGY, 1990, 41 (02) :86-91
[2]   ROUND (HELICAL) ATELECTASIS [J].
CHO, SR ;
HENRY, DA ;
BEACHLEY, MC ;
BROOKS, JW .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (644) :643-650
[3]   PET-FDG IMAGING AND TRANSTHORACIC NEEDLE LUNG ASPIRATION BIOPSY IN EVALUATION OF PULMONARY-LESIONS - A COMPARATIVE RISK-BENEFIT ANALYSIS [J].
DEWAN, NA ;
REEB, SD ;
GUPTA, NC ;
GOBAR, LS ;
SCOTT, WJ .
CHEST, 1995, 108 (02) :441-446
[4]   CT FEATURES OF ROUNDED ATELECTASIS OF THE LUNG [J].
DOYLE, TC ;
LAWLER, GA .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (02) :225-228
[5]  
Gilkeson Robert C., 1998, Clin Positron Imaging, V1, P229, DOI 10.1016/S1095-0397(98)00019-3
[6]   Accuracy of positron emission tomography for diagnosis of pulmonary nodules and mass lesions - A meta-analysis [J].
Gould, MK ;
Maclean, CC ;
Kuschner, WG ;
Rydzak, CE ;
Owens, DK .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2001, 285 (07) :914-924
[7]   SOLITARY PULMONARY NODULES - DETECTION OF MALIGNANCY WITH PET WITH 2-[F-18]-FLUORO-2-DEOXY-D-GLUCOSE [J].
GUPTA, NC ;
FRANK, AR ;
DEWAN, NA ;
REDEPENNING, LS ;
ROTHBERG, ML ;
MAILLIARD, JA ;
PHALEN, JJ ;
SUNDERLAND, JJ ;
FRICK, MP .
RADIOLOGY, 1992, 184 (02) :441-444
[8]   ROUND ATELECTASIS [J].
HANKE, R ;
KRETZSCHMAR, R .
SEMINARS IN ROENTGENOLOGY, 1980, 15 (02) :174-182
[9]   Evaluation of patients with round atelectasis using 2-[18F]fluoro-2-deoxy-D-glucose PET [J].
McAdams, HP ;
Erasmus, JJ ;
Patz, EF ;
Goodman, PC ;
Coleman, RE .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1998, 22 (04) :601-604
[10]   CT FEATURES OF ROUNDED ATELECTASIS [J].
MCHUGH, K ;
BLAQUIERE, RM .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (02) :257-260