Dynamic K-edge Subtraction Fluoroscopy at a Compact Inverse-Compton Synchrotron X-ray Source

被引:8
作者
Kulpe, Stephanie [1 ,2 ]
Dierolf, Martin [1 ,2 ]
Guenther, Benedikt [1 ,2 ]
Brantl, Johannes [1 ,2 ]
Busse, Madleen [1 ,2 ]
Achterhold, Klaus [1 ,2 ]
Gleich, Bernhard [2 ]
Pfeiffer, Franz [1 ,2 ,3 ,4 ]
Pfeiffer, Daniela [3 ,4 ]
机构
[1] Tech Univ Munich, Dept Phys, Chair Biomed Phys, James Franck Str 1, D-85748 Garching, Germany
[2] Tech Univ Munich, Munich Sch BioEngn, Boltzmannstr 11, D-85748 Garching, Germany
[3] Munich Sch Med, Dept Diagnost & Intervent Radiol, Ismaniger Str 22, D-81675 Munich, Germany
[4] Klinikum Rechts Der Isar, Ismaniger Str 22, D-81675 Munich, Germany
关键词
DUAL-ENERGY CT; COMPUTED-TOMOGRAPHY; CORONARY-ANGIOGRAPHY; RADIATION; GADOLINIUM; FEASIBILITY; PERFORMANCE;
D O I
10.1038/s41598-020-66414-x
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
X-ray fluoroscopy is a commonly applied diagnostic tool for morphological and functional evaluation of the intestine in clinical routine. Acquisition of repetitive X-ray images following oral or rectal application of iodine contrast agent visualizes the time dependent distribution of the contrast medium, and helps to detect for example leakages, tumors or functional disorders. However, movements of the intestine and air trapped inside usually prevent temporal subtraction imaging to be applied to fluoroscopy of the gastrointestinal tract. K-edge subtraction (KES) imaging would enable subtraction fluoroscopy because it allows for imaging of moving organs with little artefacts. Although KES imaging is a well established technique at synchrotron sources, this imaging method is not applied in clinical routine as it relies on brilliant synchrotron radiation. Recently emerging compact synchrotron X-ray sources could provide a quasi-monochromatic, high-flux X-ray beam and allow for the application of KES in a laboratory environment. Here, we present a filter-based dynamic KES approach at the Munich Compact Light Source (MuCLS), the first user-dedicated installation of a compact synchrotron X-ray source worldwide. Compared to conventional temporal subtraction X-ray radiography, our approach increases the contrast while reducing the generated image artefacts.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Effects of total variation regularization noise reduction algorithm in improved K-edge log-subtraction X-ray images with photon-counting cadmium telluride detectors
    Kim, Kyuseok
    Lee, Youngjin
    OPTIK, 2020, 206
  • [42] Effect of zirconium oxide local structure on soft x-ray optical properties near the oxygen K-edge region
    Sinha, Mangalika
    Gupta, Rajkumar
    Kiranjot
    Singh, Amol
    Modi, Mohammed H.
    JOURNAL OF APPLIED PHYSICS, 2020, 128 (06)
  • [43] Experimental Study of Material K-Edge Characteristics Identification Based on X-ray Photon-Counting Detection Technique
    He Peng
    Wu Xiao-chuan
    An Kang
    Deng Gang
    Wang Xing
    Zhou Zhong-xing
    Wei Biao
    Feng Peng
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2018, 38 (12) : 3929 - 3933
  • [44] NEXAFS at nitrogen K-edge and titanium L-edge using a laser-plasma soft x-ray source based on a double-stream gas puff target
    Wachulak, Przemyslaw
    Duda, Martin
    Bartnik, Andrzej
    Wegrzynski, Lukasz
    Fok, Tomasz
    Fiedorowicz, Henryk
    APL PHOTONICS, 2019, 4 (03)
  • [45] Direct monitoring of the potassium charge carrier in Prussian blue cathodes using potassium K-edge X-ray absorption spectroscopy
    Mayer, Alexander J.
    Beynon, Owain T.
    Logsdail, Andrew J.
    Wijayantha, K. G. Upul
    Dann, Sandra E.
    Marco, Jose F.
    Elliott, Joshua D.
    Aramini, Matteo
    Cibin, Giannantonio
    Kondrat, Simon A.
    JOURNAL OF MATERIALS CHEMISTRY A, 2023, 11 (37) : 19900 - 19913
  • [46] Experimental results of use of triple-energy X-ray beam with K-edge filter in multi-energy imaging
    Kim, D.
    Lee, S.
    Jeon, P. -H.
    JOURNAL OF INSTRUMENTATION, 2016, 11
  • [47] Towards In Vivo K-Edge X-Ray Micro-CT with the Pixirad-I/Pixie-III Detector
    Brun, F.
    Di Trapani, V.
    Dreossi, D.
    Rigon, L.
    Longo, R.
    Delogu, P.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 1, 2019, 68 (01): : 123 - 126
  • [48] Niobium K-Edge X-ray Absorption Spectroscopy of Doped TiO2 Produced from Ilmenite Digested in Hydrochloric Acid
    Haverkamp, Richard G.
    Kappen, Peter
    Sizeland, Katie H.
    Wallwork, Kia S.
    ACS OMEGA, 2022, : 28258 - 28264
  • [49] EXAFS of titanium LIII edge using a compact laboratory system based on a laser-plasma soft X-ray source
    Wachulak, P.
    Fok, T.
    Bartnik, A.
    Janulewicz, K. A.
    Fiedorowicz, H.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2020, 126 (01):
  • [50] Decoupling Complex Multi-Length-Scale Morphology in Non-Fullerene Photovoltaics with Nitrogen K-Edge Resonant Soft X-ray Scattering
    Zhong, Wenkai
    Zhang, Ming
    Freychet, Guillaume
    Su, Gregory M.
    Ying, Lei
    Huang, Fei
    Cao, Yong
    Zhang, Yongming
    Wang, Cheng
    Liu, Feng
    ADVANCED MATERIALS, 2022, 34 (06)