Status of the digital pixel array detector for protein crystallography

被引:20
作者
Datte, P
Birkbeck, A
Beuville, E
Endres, N
Druillole, F
Luo, L
Millaud, J
Xuong, NH
机构
[1] Univ Calif San Diego, Dept Chem & Biochem, La Jolla, CA 92093 USA
[2] Univ Calif Berkeley, Lawrence Berkeley Natl Lab, Div Engn, Berkeley, CA 94720 USA
基金
美国国家卫生研究院;
关键词
crystallography; pixel detector; area detector; image sensor; Si detector;
D O I
10.1016/S0168-9002(98)01140-1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A two-dimensional photon counting digital pixel array detector is being designed for static and time resolved protein crystallography. The room temperature detector will significantly enhance monochromatic and polychromatic protein crystallographic through-put data rates by more than three orders of magnitude. The detector has an almost infinite photon counting dynamic range and exhibits superior spatial resolution when compared to present crystallographic phosphor imaging plates or phosphor coupled CCD detectors. The detector is a high resistivity N-type Si with a pixel pitch of 150 x 150 mu m, and a thickness of 300 mu m, and is bump bonded to an application specific integrated circuit. The event driven readout of the detector is based on the column architecture and allows an independent pixel hit rate above 1 million photons/s/pixel. The device provides energy discrimination and sparse data readout which yields minimal dead-time. This type of architecture allows a continuous (frameless) data acquisition, a feature not found in any current detector being used for protein crystallographic applications. For the targeted detector size of 1000 x 1000 pixels, average hit rates greater than 8 billion photons/s for the complete detector appears achievable. This paper will present a review of the 8 x 8 detector array pixel performance which includes the analog amplifier response and the photon counting capabilities. In addition, operational results of a 16 x 16 detector array prototype, that includes both the analog amplifier and digital readout circuitry functioning together on one integrated circuit. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:576 / 590
页数:15
相关论文
共 9 条
[1]   Characterization of a prototype pixel array detector (PAD) for use in microsecond framing time-resolved x-ray diffraction studies [J].
Barna, SL ;
Shepherd, JA ;
Tate, MW ;
Wixted, RL ;
Eikenberry, EF ;
Gruner, SM .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (03) :950-956
[2]   Two-dimensional pixel array image sensor for protein crystallography [J].
Beuville, E ;
Beche, JF ;
Cork, C ;
Douence, V ;
Earnest, T ;
Millaud, J ;
Nygren, D ;
Padmore, H ;
Turko, B ;
Zizka, G ;
Datte, P ;
Xuong, NH .
HARD X-RAY/GAMMA-RAY AND NEUTRON OPTICS, SENSORS, AND APPLICATIONS, 1996, 2859 :85-92
[3]   A 2D smart Pixel Detector for Time Resolved protein Crystallography [J].
Beuville, E ;
Cork, C ;
Earnest, T ;
Mar, W ;
Millaud, J ;
Nygren, D ;
Padmore, H ;
Turko, B ;
Zizka, G ;
Datte, P ;
Xuong, NH .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1243-1247
[4]   A prototype 8x8 pixel array X-ray detector for protein crystallography [J].
Datte, P ;
Beuville, E ;
Beche, JF ;
Cork, C ;
Earnest, T ;
Millaud, J ;
Nygren, D ;
Padmore, H ;
Turko, B ;
Xuong, NH .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 391 (03) :471-480
[5]  
*INT DEV TECHN INC, 1997, INT DEV TECHN INC DA
[6]  
MILLAUD J, 1996, IEEE T NUCL SCI, V43, P1243
[7]  
ROSSINGTON C, 1997 IEEE NUCL SCI S
[8]  
XUONG NH, 1996, P 17 INT UN CRYST C, pC20
[9]  
1993, CYPRESS SEMICONDUCTO