Differences in micromorphology of the implant-abutment junction for original and third-party abutments on a representative dental implant

被引:16
作者
Fokas, George [1 ]
Ma, Li [1 ]
Chronopoulos, Vasilios [2 ]
Janda, Martin [3 ]
Mattheos, Nikos [1 ]
机构
[1] Univ Hong Kong, Fac Dent, Hong Kong, Peoples R China
[2] Univ Athens, Fac Dent, Athens, Greece
[3] Publ Dent Hlth Serv, Specialist Clin Prosthodont, Lund, Sweden
关键词
COMPLICATION RATES; BACTERIAL LEAKAGE; SURVIVAL; SCREW; CONNECTIONS; PROSTHESES; INTERFACE; REMOVAL; CAST;
D O I
10.1016/j.prosdent.2018.02.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Evidence for micromorphology and precision of fit of third-party prosthetic components compared with the original manufacturer's components is lacking. Purpose. The purpose of this in vitro pilot study was to evaluate the micromorphological differences among different commercial brands of zirconia, titanium, and gold abutments for dental implants in terms of tight surface contact. Materials and method. The following abutments (n=3 per type) were preloaded on Straumann Bone Level implants according to the manufacturer's instructions for zirconia (Zr, Zr2, Zr3), titanium (Ti and Ti2), and gold (Gold 1, Gold 2). The micromorphology of the implant-abutment units was investigated by using scanning electron microscopy (original magnification x10 to x500) after microtome sectioning. After we calibrated, the length of the areas with tight contact (TC) (discrepancy <= 3 mu m) was calculated at the level of conical connection (CC), lower internal connection (LIC), and screw threads (STs). The interexaminer agreement was assessed by using intraclass correlation coefficient(s) (ICC). One-way ANOVA was used for the overall comparison of the Zr groups, and the Student paired t test was used for pairwise comparisons of the abutments of the same group. After we adjusted for multiple comparisons, the significance level for the overall and pairwise comparisons of Ti and Gold groups was set at a P value of .008 and a P value of .003 for the Zr groups. Results. Major differences were found among the different abutment types in terms of design and extent of surface contact. The TC showed significant differences among the abutments of Zr group, depending on the side and level of evaluation (Zr1 > Zr2 > Zr3 on the left side for CC; Zr1, Zr2 > Zr3 on the right side for CC, and, Zr2 > Zr3 on the right side for LIC; P<.003). In Ti group, no significant differences were found (P>.008). The Gold and Gold 2 groups had significantly greater contact on the left side of CC (P<.008). Conclusion. A difference in design of the abutments was apparent. The tight surface contact was significantly different among the examined abutments or abutment screws and the respective area of the inner surface of the implants.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 30 条
[1]  
[Anonymous], 2014, J DENT BIOMECH
[2]   PHOTOELASTIC STRESS ANALYSIS OF EXTERNAL VERSUS INTERNAL IMPLANT-ABUTMENT CONNECTIONS [J].
Asvanund, Pattapon ;
Morgano, Steven M. .
JOURNAL OF PROSTHETIC DENTISTRY, 2011, 106 (04) :266-271
[3]   Effect of the coefficient of friction and tightening speed on the preload induced at the dental implant complex with the finite element method [J].
Bulaqi, Haddad Arabi ;
Mashhadi, Mahmoud Mousavi ;
Geramipanah, Farideh ;
Safari, Hamed ;
Paknejad, Mojgan .
JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (05) :405-411
[4]   Torque removal evaluation of prosthetic screws after tightening and loosening cycles: an in vitro study [J].
Cardoso, Mayra ;
Torres, Marcelo Ferreira ;
Veras Lourenco, Eduardo Jose ;
Telles, Daniel de Moraes ;
Silveira Rodrigues, Renata Cristina ;
Ribeiro, Ricardo Faria .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (04) :475-480
[5]   Prosthetic outcome of cement-retained implant-supported fixed dental restorations: a systematic review [J].
Chaar, M. S. ;
Att, W. ;
Strub, J. R. .
JOURNAL OF ORAL REHABILITATION, 2011, 38 (09) :697-711
[6]  
Coppede AR, 2013, INT J ORAL MAX IMPL, V28, pE321, DOI 10.11607/jomi.3029
[7]   Bacterial leakage along the implant-abutment interface of premachined or cast components [J].
do Nascimento, C. ;
Barbosa, R. E. S. ;
Issa, J. P. M. ;
Watanabe, E. ;
Ito, I. Y. ;
Junior, R. F. Albuquerque .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2008, 37 (02) :177-180
[8]   Use of checkerboard DNA-DNA hybridization to evaluate the internal contamination of dental implants and comparison of bacterial leakage with cast or pre-machined abutments [J].
do Nascimento, Cassio ;
Santos Barbosa, Rodrigo Edson ;
Mardegan Issa, Joao Paulo ;
Watanabe, Evandro ;
Ito, Izabel Yoko ;
de Albuquerque, Rubens Ferreira, Jr. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (06) :571-577
[9]   Effect of implant connection and restoration design (screwed vs. cemented) in reliability and failure modes of anterior crowns [J].
Freitas, Amilcar C., Jr. ;
Bonfante, Estevam A. ;
Rocha, Eduardo P. ;
Silva, Nelson R. F. A. ;
Marotta, Leonard ;
Coelho, Paulo G. .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2011, 119 (04) :323-330
[10]   Implants with Original and Non-Original Abutment Connections [J].
Gigandet, Michel ;
Bigolin, Gianni ;
Faoro, Francisco ;
Buergin, Walter ;
Braegger, Urs .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2014, 16 (02) :303-311