Implementation of a dose calculation algorithm based on Monte Carlo simulations for treatment planning towards MRI guided ion beam therapy

被引:16
作者
Padilla-Cabal, Fatima [1 ,2 ]
Resch, Andreas Franz [1 ,2 ]
Georg, Dietmar [1 ,2 ]
Fuchs, Hermann [1 ,2 ]
机构
[1] Med Univ Vienna AKH, Dept Radiat Oncol, Vienna, Austria
[2] Med Univ Vienna, Christian Doppler Lab Med Radiat Res Radiat Oncol, Vienna, Austria
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2020年 / 74卷
基金
奥地利科学基金会;
关键词
Treatment planning; Proton therapy; Magnetic fields; MODULATED PROTON THERAPY; SCANNED PROTON; MAGNETIC-FIELD; RADIOTHERAPY; HELIUM; OPTIMIZATION; FEASIBILITY; DEFLECTION; SCATTERING; CARBON;
D O I
10.1016/j.ejmp.2020.04.027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Magnetic resonance guidance in particle therapy has the potential to improve the current performance of clinical workflows. However, the presence of magnetic fields challenges the current algorithms for treatment planning. To ensure proper dose calculations, compensation methods are required to guarantee that the maximum deposited energy of deflected beams lies in the target volume. In addition, proper modifications of the intrinsic dose calculation engines, accounting for magnetic fields, are needed. In this work, an algorithm for proton treatment planning in magnetic fields was implemented in a research treatment planning system (TPS), matRad. Setup-specific look up tables were generated using a validated MC model for a clinical proton beamline (62.4 - 215.7 MeV) interacting with a dipole magnet (B = 0-1 T). The algorithm was successfully benchmarked against MC simulations in water, showing gamma index (2%/2mm) global pass rates higher than 96% for different plan configurations. Additionally, absorbed depth doses were compared with experimental measurements in water. Differences within 2% and 3.5% in the Bragg peak and entrance regions, respectively, were found. Finally, treatment plans were generated and optimized for magnetic field strengths of 0 and 1 T to assess the performance of the proposed model. Equivalent treatment plans and dose volume histograms were achieved, independently of the magnetic field strength. Differences lower than 1.5% for plan quality indicators (D-2%, D-50%, D-90%, V-95% and V-105%) in water, a TG119 phantom and an exemplary prostate patient case were obtained. More complex treatment planning studies are foreseen to establish the limits of applicability of the proposed model.
引用
收藏
页码:155 / 165
页数:11
相关论文
共 55 条
  • [1] GEANT4-a simulation toolkit
    Agostinelli, S
    Allison, J
    Amako, K
    Apostolakis, J
    Araujo, H
    Arce, P
    Asai, M
    Axen, D
    Banerjee, S
    Barrand, G
    Behner, F
    Bellagamba, L
    Boudreau, J
    Broglia, L
    Brunengo, A
    Burkhardt, H
    Chauvie, S
    Chuma, J
    Chytracek, R
    Cooperman, G
    Cosmo, G
    Degtyarenko, P
    Dell'Acqua, A
    Depaola, G
    Dietrich, D
    Enami, R
    Feliciello, A
    Ferguson, C
    Fesefeldt, H
    Folger, G
    Foppiano, F
    Forti, A
    Garelli, S
    Giani, S
    Giannitrapani, R
    Gibin, D
    Cadenas, JJG
    González, I
    Abril, GG
    Greeniaus, G
    Greiner, W
    Grichine, V
    Grossheim, A
    Guatelli, S
    Gumplinger, P
    Hamatsu, R
    Hashimoto, K
    Hasui, H
    Heikkinen, A
    Howard, A
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 506 (03) : 250 - 303
  • [2] A model for the accurate computation of the lateral scattering of protons in water
    Bellinzona, E. V.
    Ciocca, M.
    Embriaco, A.
    Ferrari, A.
    Fontana, A.
    Mairani, A.
    Parodi, K.
    Rotondi, A.
    Sala, P.
    Tessonnier, T.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (04) : N102 - N117
  • [3] On the parametrization of lateral dose profiles in proton radiation therapy
    Bellinzona, V. E.
    Ciocca, M.
    Embriaco, A.
    Fontana, A.
    Mairani, A.
    Mori, M.
    Parodi, K.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (05): : 484 - 492
  • [4] MRI-guided proton therapy planning: accounting for an inline MRI fringe field
    Burigo, Lucas N.
    Oborn, Bradley M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21)
  • [5] Shared data for intensity modulated radiation therapy (IMRT) optimization research: the CORT dataset
    Craft, David
    Bangert, Mark
    Long, Troy
    Papp, David
    Unkelbach, Jan
    [J]. GIGASCIENCE, 2014, 3
  • [6] Fast Pencil Beam Dose calculation for Proton Therapy Using a Double-Gaussian Beam Model
    da Silva, Joakim
    Ansorge, Richard
    Jena, Rajesh
    [J]. FRONTIERS IN ONCOLOGY, 2015, 5
  • [7] Application of the pencil-beam redefinition algorithm in heterogeneous media for proton beam therapy
    Egashira, Y.
    Nishio, T.
    Hotta, K.
    Kohno, R.
    Uesaka, M.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (04) : 1169 - 1184
  • [8] Elia A., 2019, CHARACTERIZATION GAT, DOI [10.1016/j.zemedi.2011.12.001, DOI 10.1016/J.ZEMEDI.2011.12.001]
  • [9] Ferrari A, 2005, CERN2005010, P406
  • [10] On the quantitative modelling of core and tails of multiple scattering by Gaussian mixtures
    Frühwirth, R
    Regler, M
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 456 (03) : 369 - 389