An ISFET-based penicillin sensor with high sensitivity, low detection limit and long lifetime

被引:62
|
作者
Poghossian, A [1 ]
Schöning, MJ
Schroth, P
Simonis, A
Lüth, H
机构
[1] Res Ctr Julich GMBH, Inst Thin Film & Ion Technol, D-52425 Julich, Germany
[2] Univ Appl Sci Aachem, D-52428 Julich, Germany
来源
SENSORS AND ACTUATORS B-CHEMICAL | 2001年 / 76卷 / 1-3期
关键词
penicillin; EnFET; adsorptive immobilisation; high sensitivity; low detection limit; long lifetime;
D O I
10.1016/S0925-4005(01)00609-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
By choosing an optimal pH-sensitive transducer material and a low capacity polymix buffer, excellent working characteristics were achieved for a penicillin-sensitive field-effect transistor (PenFET) with adsorptively immobilised penicillinase. The developed PenFET possesses a high sensitivity of 120 +/- 10 mV/mM in the concentration range of 0.05-1 mM penicillin G, a low detection limit of 5 muM, a small hysteresis of less than 4 mV and a long lifetime of more than 1 year. For the PenFET a temperature-independent working point was found. A simple biosensor regeneration in the case of loss of the enzyme activity is experimentally demonstrated. A pH ISFET/PenFET dual chip is developed and investigated in order to eliminate disturbing factors such as temperature and drift influences as well as the possible variation of the pH of the bulk solution. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:519 / 526
页数:8
相关论文
共 50 条
  • [1] An ISFET-based immunosensor for the detection of β-Bungarotoxin
    Selvanayagam, ZE
    Neuzil, P
    Gopalakrishnakone, P
    Sridhar, U
    Singh, M
    Ho, LC
    BIOSENSORS & BIOELECTRONICS, 2002, 17 (09): : 821 - 826
  • [2] An ISFET-based anion sensor for the potentiometric detection of organic acids in liquid chromatography
    Poels, I
    Schasfoort, RBM
    Picioreanu, S
    Frank, J
    van Dedem, GWK
    van den Berg, A
    Nagels, LJ
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 67 (03) : 294 - 299
  • [3] DYNAMIC BEHAVIOR OF ISFET-BASED SENSOR ACTUATOR SYSTEMS
    OLTHUIS, W
    LUO, J
    VANDERSCHOOT, BH
    BOMER, JG
    BERGVELD, P
    SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) : 416 - 420
  • [4] REFET Replication for ISFET-based SNP Detection Arrays
    Sohbati, Mohammadreza
    Georgiou, Pantelis
    Toumazou, Christofer
    2013 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS), 2013, : 185 - 188
  • [5] AN ISFET-BASED CALCIUM SENSOR USING A PHOTOPOLYMERIZED POLYSILOXANE MEMBRANE
    VANDENBERG, A
    GRISEL, A
    VERNEYNORBERG, E
    SENSORS AND ACTUATORS B-CHEMICAL, 1991, 4 (3-4) : 235 - 238
  • [6] A Temperature Independent Readout Circuit for ISFET-Based Sensor Applications
    Moussavi, Elmira
    Sisejkovic, Dominik
    Singh, Animesh
    Kizatov, Daniyar
    Leupers, Rainer
    Ingebrandt, Sven
    Pachauri, Vivek
    Merchant, Farhad
    2022 23RD IEEE LATIN-AMERICAN TEST SYMPOSIUM (LATS 2022), 2022,
  • [7] High sensitivity and low detection limit sensor based on a slotted nanobeam cavity in silicon
    Al-Hmoud, Mohannad
    Alyahyan, Rasha
    PHOTONICS LETTERS OF POLAND, 2022, 14 (03) : 59 - 61
  • [8] ISFET-based aptasensor for thrombin detection using horseradish peroxidase
    Andrianova, Mariia S.
    Grudtsov, Vitaliy P.
    Komarova, Natalia V.
    Kuznetsov, Evgeniy V.
    Kuznetsov, Alexander E.
    13TH GLOBAL CONGRESS ON MANUFACTURING AND MANAGEMENT, 2017, 174 : 1084 - 1092
  • [9] Protein detection with a novel ISFET-based zeta potential analyzer
    Koch, S
    Woias, P
    Meixner, LK
    Drost, S
    Wolf, H
    BIOSENSORS & BIOELECTRONICS, 1999, 14 (04): : 413 - 421
  • [10] Detachable Flexible ISFET-Based pH Sensor Array with a Flexible Connector
    Honda, Satoko
    Shiomi, Mao
    Yamaguchi, Takafumi
    Fujita, Yusuke
    Arie, Takayuki
    Akita, Seiji
    Takei, Kuniharu
    ADVANCED ELECTRONIC MATERIALS, 2020, 6 (10)