A comparison of the mechanical properties of fire-resistant and S275 structural steels

被引:54
作者
Kelly, FS
Sha, W
机构
[1] Peter Brett Associates, London W6 9DA, England
[2] Queens Univ Belfast, Dept Civil Engn, Belfast BT7 1NN, Antrim, North Ireland
关键词
fire; structures; steel; fire protection;
D O I
10.1016/S0143-974X(98)00252-1
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The mechanical properties of two fire-resistant (FR) structural steels and an S275 steel have been investigated from room temperature up to 700 degrees C, with the aim of assessing the viability of FR steels. The major focus has been on the tensile and creep properties of the steels at high temperature and the effect of these properties on the fire resistance of model steel beams. It has been found that the FR steels performed significantly better than the S275 at high temperature, retaining 50% of their room temperature strength at a temperature of approximately 650 degrees C. The S275 steel retained 50% strength to a temperature of 550 degrees C, this being consistent with literature values. In creep tests carried out at 600 degrees C, the FR steels also exhibited lower maximum strains and strain rates than the S275. The improved strength reduction factors led to a significant increase in fire resistance for a model steel beam with various floor slab configurations, showing that FR steels can become a practical alternative to conventional structural steels. (C) 1999 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:223 / 233
页数:11
相关论文
共 11 条
[1]  
*BRIT STAND I, 1996, 101091 BS EN BRIT ST
[2]  
CHIJIIWA R, 1995, HSLA STEELS 95 C P, P584
[3]  
DOWLING J, 1997, P I CIV ENG STRUCTS, V112, P237
[4]  
HONEYCOMBE RWK, 1995, STEELS MICROSTRUCTUR, P290
[5]  
Kelly FS, 1997, EUROMAT 97 - PROCEEDINGS OF THE 5TH EUROPEAN CONFERENCE ON ADVANCED MATERIALS AND PROCESSES AND APPLICATIONS: MATERIALS, FUNCTIONALITY & DESIGN, VOL 1, P35
[6]  
LAWSON RM, 1996, 159 STEEL CONSTR I, P22
[7]  
MORRISON WB, 1985, C P ONT CAN MARCH 4
[8]   HIGH-TEMPERATURE PROPERTIES OF FIRE-RESISTANT STEEL FOR BUILDINGS [J].
SAKUMOTO, Y ;
YAMAGUCHI, T ;
OHASHI, M ;
SAITO, H .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1992, 118 (02) :392-407
[9]   Fire resistance of floors constructed with fire-resistant steels [J].
Sha, W .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1998, 124 (06) :664-670
[10]  
1996, STEEL CONCRETE EC CO