摘要
Background. Confidence in bioprosthetic durability without anticoagulation has led to a contemporary trend of offering tissue valves to younger patients. Close monitoring of mechanical valve patients at lower international normalized ratio (INR) thresholds may reduce anticoagulation morbidity. We prospectively compared results of bioprostheses (BP) and a bileaflet mechanical prosthesis (MP) monitored at low INR thresholds. Methods. Patients received an isolated Carpentier-Edwards bovine or Medtronic porcine BP or the On-X MP. INR targets were 2.0 for MP recipients undergoing aortic valve replacement and 2.5 for mitral valve replacement, using point-of-care home monitoring. Operations consecutively performed between September 2003 and August 2007 were propensity matched using logistic regression by preoperative covariates of age, sex, valve position, New York Heart Association class, ejection fraction, atrial fibrillation, and creatinine. Results. Of 469 operations consecutively performed, 172 patients were matched for analysis. Mean age was 56.2 +/- 9.6 years (range, 24 to 72 years). Median follow-up was 4.0 years (total follow-up, 667.0 patient-years). No late bleeding events occurred. The thromboembolic complication rates per patient-year were 0.77% for MP and 0.78% for BP (p = 0.67). There were 9 BP deaths vs 4 MP (2.35% vs 1.41%/ patient-year; BP hazard ratio, 0.60; 95% confidence interval, 0.13 to 2.15). Postoperative linearized mortality benefit of MP was observed as early as 5 years, reaching significance at 7.5 years (p = 0.04). Conclusions: Patients aged 65 years or younger with MP and closely monitored anticoagulation display non-inferiority to BP from bleeding and thromboembolic complications. MP valves begin to confer mortality benefit over BP as early as 7.5 years postoperatively. Because this predates the timeline of typical structural valve degeneration, equipoise is suggested when choosing a BP in a young patient with future expectations of valve-in-valve intervention. (Ann Thorac Surg 2012;93:748-53) (C) 2012 by The Society of Thoracic Surgeons
引用
收藏
页码:748 / 753
页数:6
相关论文
共 33 条
[1]  
Akins CW, 2008, ANN THORAC SURG, V85, P1490, DOI [10.1016/j.athoracsur.2007.12.082, 10.1016/j.ejcts.2007.12.055]
[2]   Age and valve size effect on the long-term durability of the Carpentier-Edwards aortic pericardial bioprosthesis [J].
Banbury, MK ;
Cosgrove, DM ;
White, JA ;
Blackstone, EH ;
Frater, RWM ;
Okies, JE .
ANNALS OF THORACIC SURGERY, 2001, 72 (03) :753-757
[3]   Surgery for aortic and mitral valve disease in the United States: A trend of change in surgical practice between 1998 and 2005 [J].
Barnett, Scott D. ;
Ad, Niv .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (06) :1422-1429
[4]  
Biglioli P, 2004, J HEART VALVE DIS, V13, pS49
[5]   Comparing apples and oranges [J].
Blackstone, EH .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (01) :8-15
[6]  
Bonow Robert O, 2008, Circulation, V118, pe523, DOI 10.1161/CIRCULATIONAHA.108.190748
[7]   Aortic valve replacement in patients aged 50 to 70 years: Improved outcome with mechanical versus biologic prostheses [J].
Brown, Morgan L. ;
Schaff, Hartzell V. ;
Lahr, Brian D. ;
Mullany, Charles J. ;
Sundt, Thoralf M. ;
Dearani, Joseph A. ;
McGregor, Christopher G. ;
Orszulak, Thomas A. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (04) :878-884
[8]   Influence of the On-X mechanical prosthesis on intermediate-term major thromboembolism and hemorrhage: A prospective multicenter study [J].
Chan, Vincent ;
Jamieson, W. R. Eric ;
Lam, B-Khanh ;
Ruel, Marc ;
Ling, Hilton ;
Fradet, Guy ;
Mesana, Thierry G. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 140 (05) :1053-U168
[9]   Optimal antithrombotic therapy for mechanical prosthetic heart valves [J].
Chesebro, JH ;
Fuster, V .
CIRCULATION, 1996, 94 (09) :2055-2056
[10]  
COX DR, 1972, J R STAT SOC B, V34, P187