Systematic study on the relationship between particulate matter and microbial counts in hospital operating rooms

被引:23
作者
Tan, Huiyi [1 ]
Wong, Keng Yinn [2 ,3 ]
Nyakuma, Bemgba Bevan [4 ]
Kamar, Haslinda Mohamed [2 ]
Chong, Wen Tong [5 ]
Luing Wong, Syie [6 ]
Kang, Hooi Siang [2 ]
机构
[1] Univ Teknol Malaysia, Sch Chem & Energy Engn, Fac Engn, Skudai 81310, Johor, Malaysia
[2] Univ Teknol Malaysia, Sch Mech Engn, Fac Engn, Skudai 81310, Johor, Malaysia
[3] Univ Teknol Malaysia, Proc Syst Engn Ctr PROSPECT, Fac Engn, Skudai 81310, Johor, Malaysia
[4] Benue State Univ, Dept Chem, Fac Sci, PMB 102119, Makurdi, Benue State, Nigeria
[5] Univ Malaya, Dept Mech Engn, Fac Engn, Kuala Lumpur 50603, Malaysia
[6] Univ Rey Juan Carlos, Dept Matemat Aplicada Ciencia & Ingn Mat & Tecnol, C Tulipan S-N, Madrid, Spain
关键词
Operating room; Particulate matter; Microbial count; Air change rate; Differential pressure; Onsite sampling; SURGICAL SITE INFECTION; LAMINAR AIR-FLOW; AIRBORNE BACTERIA; CONTAMINATION; DOOR; CARE; IMPACT; COSTS; RATES;
D O I
10.1007/s11356-021-16171-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In this study, a systematic procedure for establishing the relationship between particulate matter (PM) and microbial counts in four operating rooms (ORs) was developed. The ORs are located in a private hospital on the western coast of Peninsular Malaysia. The objective of developing the systematic procedure is to ensure that the correlation between the PMs and microbial counts are valid. Each of the procedures is conducted based on the ISO, IEST, and NEBB standards. The procedures involved verifying the operating parameters are air change rate, room differential pressure, relative humidity, and air temperature. Upon verifying that the OR parameters are in the recommended operating range, the measurements of the PMs and sampling of the microbes were conducted. The TSI 9510-02 particle counter was used to measure three different sizes of PMs: PM 0.5, PM 5, and PM 10. The MAS-100ECO air sampler was used to quantify the microbial counts. The present study confirms that PM 0.5 does not have an apparent positive correlation with the microbial count. However, the evident correlation of 7% and 15% were identified for both PM 5 and PM 10, respectively. Therefore, it is suggested that frequent monitoring of both PM 5 and PM 10 should be practised in an OR before each surgical procedure. This correlation approach could provide an instantaneous estimation of the microbial counts present in the OR.
引用
收藏
页码:6710 / 6721
页数:12
相关论文
共 83 条
[1]   Analysis of Bacterial and Fungal Infections after Cytoreduction Surgery and Hyperthermic Intraperitoneal Chemotherapy: An Observational Single-Centre Study [J].
Albukhari, Talat A. M. ;
Nafady-Hego, Hanaa ;
Elgendy, Hamed ;
Abd Elmoneimi, Hanan M. ;
Nafady, Asmaa ;
Alzahrani, Abdulaziz M. .
INTERNATIONAL JOURNAL OF MICROBIOLOGY, 2019, 2019
[2]  
Allegranzi Benedetta, 2016, Lancet Infect Dis, V16, pe276, DOI [10.1016/s1473-3099(16)30402-9, 10.1016/s1473-3099(16)30398-x, 10.1016/S1473-3099(16)30398-X]
[3]   Traffic flow in the operating room: An explorative and descriptive study on air quality during orthopedic trauma implant surgery [J].
Andersson, Annette Erichsen ;
Bergh, Ingrid ;
Karlsson, Jon ;
Eriksson, Bengt I. ;
Nilsson, Kerstin .
AMERICAN JOURNAL OF INFECTION CONTROL, 2012, 40 (08) :750-755
[4]   Water jet velocity uncertainty in laser Doppler velocimetry measurements [J].
Annoni, Massimiliano .
MEASUREMENT, 2012, 45 (06) :1639-1650
[5]  
[Anonymous], 2013, SURVEILLANCE SURG SI
[6]   Impact of surgical site infection on healthcare costs and patient outcomes: a systematic review in six European countries [J].
Badia, J. M. ;
Casey, A. L. ;
Petrosillo, N. ;
Hudson, P. M. ;
Mitchell, S. A. ;
Crosby, C. .
JOURNAL OF HOSPITAL INFECTION, 2017, 96 (01) :1-15
[7]  
Berechet Mariana Daniela, 2019, Revista de Pielarie Incalțaminte, V19, P201, DOI [10.24264/lfj.19.4.5, 10.24264/lfj.19.4.5]
[8]  
Bruce N, 2007, AM J INFECT CONTROL, V35, pE191, DOI DOI 10.1016/J.AJIC.2007.04.212
[9]   Conflicting effects of a portable ultra-clean airflow unit on the sterility of operating rooms: A numerical investigation [J].
Casagrande, Diego ;
Piller, Marzio .
BUILDING AND ENVIRONMENT, 2020, 171
[10]   Conversion of operating theatre from positive to negative pressure environment [J].
Chow, T. T. ;
Kwan, A. ;
Lin, Z. ;
Bai, W. .
JOURNAL OF HOSPITAL INFECTION, 2006, 64 (04) :371-378