In-line fiber Bragg grating sensors for steel corrosion detection

被引:0
作者
Deng, Fodan [1 ]
Huang, Ying [1 ]
Azarmi, Fardad [2 ]
机构
[1] North Dakota State Univ, Dept Civil Engn, PO 6050, Fargo, ND 58108 USA
[2] North Dakota State Univ, Dept Mech Engn, PO 6050, Fargo, ND 58108 USA
来源
SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE SYSTEMS 2016 | 2016年 / 9803卷
关键词
Steel Corrosion Detection; FBG sensor;
D O I
10.1117/12.2219751
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A corrosion monitoring system for steel using Fiber Bragg grating (FBG) sensors is proposed. FBG sensors were protected by hypodermic tubes and a layer of adhesive. The increase in volume caused by the presence of corrosion product introduces strain that can be monitored by FBG sensors. Experimental results showed a positive correlation between the strain and corrosion product, and the change in central wavelength has the potential to serve as an indicator for material weight loss due to corrosion.
引用
收藏
页数:6
相关论文
共 16 条
[1]   Optical-Based Sensors for Monitoring Corrosion of Reinforcement Rebar via an Etched Cladding Bragg Grating [J].
Abu Hassan, Muhammad Rosdi ;
Abu Bakar, Muhammad Hafiz ;
Dambul, Katrina ;
Adikan, Faisal Rafiq Mahamd .
SENSORS, 2012, 12 (11) :15820-15826
[2]   Consequences of steel corrosion on the ductility properties of reinforcement bar [J].
Apostolopoulos, C. A. ;
Papadakis, V. G. .
CONSTRUCTION AND BUILDING MATERIALS, 2008, 22 (12) :2316-2324
[3]   Steel rebars corrosion investigation with strain gages [J].
Batis, G ;
Routoulas, T .
CEMENT & CONCRETE COMPOSITES, 1999, 21 (03) :163-171
[4]   Deterioration of concrete due to reinforcement steel corrosion [J].
Cabrera, JG .
CEMENT & CONCRETE COMPOSITES, 1996, 18 (01) :47-59
[5]  
Farrar Charles R, 2012, Structural health monitoring: a machine learning perspective
[6]   Fibre Bragg grating strain sensor and study of its packaging material for use in critical analysis on steel structure [J].
Gangopadhyay, Tarun Kumar ;
Majumder, Mousumi ;
Chakraborty, Ashim Kumar ;
Dikshit, Asok Kumar ;
Bhattacharya, Dipak Kumar .
SENSORS AND ACTUATORS A-PHYSICAL, 2009, 150 (01) :78-86
[7]   Monitoring of corrosion in reinforced concrete structure using Bragg grating sensing [J].
Gao, Junqi ;
Wu, Jin ;
Li, Jun ;
Zhao, Xinming .
NDT & E INTERNATIONAL, 2011, 44 (02) :202-205
[8]   FACTORS AFFECTING THE CORROSION RATE OF STEEL IN CARBONATED MORTARS [J].
GLASS, GK ;
PAGE, CL ;
SHORT, NR .
CORROSION SCIENCE, 1991, 32 (12) :1283-1294
[9]   Monitoring of Corrosion in Structural Reinforcing Bars: Performance Comparison Using In Situ Fiber-Optic and Electric Wire Strain Gauge Systems [J].
Grattan, Simon K. T. ;
Taylor, Su E. ;
Sun, Tong ;
Basheer, P. A. M. ;
Grattan, Kenneth T. V. .
IEEE SENSORS JOURNAL, 2009, 9 (11) :1494-1502
[10]   1980 INSTITUTE OF METALS LECTURE THE METALLURGICAL-SOCIETY-OF-AIME - EFFECTS OF HYDROGEN ON THE PROPERTIES OF IRON AND STEEL [J].
HIRTH, JP .
METALLURGICAL TRANSACTIONS A-PHYSICAL METALLURGY AND MATERIALS SCIENCE, 1980, 11 (06) :861-890