Machine learning driven non-invasive approach of water content estimation in living plant leaves using terahertz waves

被引:38
作者
Zahid, Adnan [1 ]
Abbas, Hasan T. [1 ]
Ren, Aifeng [1 ,2 ]
Zoha, Ahmed [1 ]
Heidari, Hadi [1 ]
Shah, Syed A. [1 ]
Imran, Muhammad A. [1 ]
Alomainy, Akram [3 ]
Abbasi, Qammer H. [1 ]
机构
[1] Univ Glasgow, James Watt Sch Engn, Glasgow, Lanark, Scotland
[2] Xidian Univ, Sch Elect Engn, Xian, Shaanxi, Peoples R China
[3] Queen Mary Univ London, Sch Elect Engn & Comp Sci, London, England
基金
英国工程与自然科学研究理事会;
关键词
Water content; Plant leaves; Terahertz (THz); Sensing; Agriculture; Classification; Machine learning; CLASSIFICATION; TECHNOLOGY; SELECTION; SECURITY;
D O I
10.1186/s13007-019-0522-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: The demand for effective use of water resources has increased because of ongoing global climate transformations in the agriculture science sector. Cost-effective and timely distributions of the appropriate amount of water are vital not only to maintain a healthy status of plants leaves but to drive the productivity of the crops and achieve economic benefits. In this regard, employing a terahertz (THz) technology can be more reliable and progressive technique due to its distinctive features. This paper presents a novel, and non-invasive machine learning (ML) driven approach using terahertz waves with a swissto12 material characterization kit (MCK) in the frequency range of 0.75 to 1.1 THz in real-life digital agriculture interventions, aiming to develop a feasible and viable technique for the precise estimation of water content (WC) in plants leaves for 4 days. For this purpose, using measurements observations data, multi-domain features are extracted from frequency, time, time-frequency domains to incorporate three different machine learning algorithms such as support vector machine (SVM), K-nearest neighbour (KNN) and decision-tree (D-Tree). Results: The results demonstrated SVM outperformed other classifiers using tenfold and leave-one-observations-out cross-validation for different days classification with an overall accuracy of 98.8%, 97.15%, and 96.82% for Coffee, pea shoot, and baby spinach leaves respectively. In addition, using SFS technique, coffee leaf showed a significant improvement of 15%, 11.9%, 6.5% in computational time for SVM, KNN and D-tree. For pea-shoot, 21.28%, 10.01%, and 8.53% of improvement was noticed in operating time for SVM, KNN and D-Tree classifiers, respectively. Lastly, baby spinach leaf exhibited a further improvement of 21.28% in SVM, 10.01% in KNN, and 8.53% in D-tree in overall operating time for classifiers. These improvements in classifiers produced significant advancements in classification accuracy, indicating a more precise quantification of WC in leaves. Conclusion: Thus, the proposed method incorporating ML using terahertz waves can be beneficial for precise estimation of WC in leaves and can provide prolific recommendations and insights for growers to take proactive actions in relations to plants health monitoring.
引用
收藏
页数:13
相关论文
共 39 条
[1]   Variability of Terahertz Transmission Measured in Live Plant Leaves [J].
Afsharinejad, Armita ;
Davy, Alan ;
Naftaly, Mira .
IEEE GEOSCIENCE AND REMOTE SENSING LETTERS, 2017, 14 (05) :636-638
[2]  
[Anonymous], 2017, SENSORS BASEL, DOI DOI 10.3390/S17122830
[3]  
Berry E, 2005, ADV PTRN RECOGNIT, P271
[4]   Monitoring Plant Drought Stress Response Using Terahertz Time-Domain Spectroscopy [J].
Born, Norman ;
Behringer, David ;
Liepelt, Sascha ;
Beyer, Sarah ;
Schwerdtfeger, Michael ;
Ziegenhagen, Birgit ;
Koch, Martin .
PLANT PHYSIOLOGY, 2014, 164 (04) :1571-1577
[5]  
Breitenstein B, 2011, J APPL BOT FOOD QUAL, V84, P158
[6]   Best hyperspectral indices for tracing leaf water status as determined from leaf dehydration experiments [J].
Cao, Zhenxing ;
Wang, Quan ;
Zheng, Chaolei .
ECOLOGICAL INDICATORS, 2015, 54 :96-107
[7]   Quantify Glucose Level in Freshly Diabetic's Blood by Terahertz Time-Domain Spectroscopy [J].
Chen, Hua ;
Chen, Xiaofeng ;
Ma, Shihua ;
Wu, Xiumei ;
Yang, Wenxing ;
Zhang, Weifeng ;
Li, Xiao .
JOURNAL OF INFRARED MILLIMETER AND TERAHERTZ WAVES, 2018, 39 (04) :399-408
[8]   Correlation technique and least square support vector machine combine for frequency domain based ECG beat classification [J].
Dutta, Saibal ;
Chatterjee, Amitava ;
Munshi, Sugata .
MEDICAL ENGINEERING & PHYSICS, 2010, 32 (10) :1161-1169
[9]  
El Beyrouthya M., 2014, ADV CROP SCI TECHNOL, V2, P8863
[10]   THz imaging and sensing for security applications - explosives, weapons and drugs [J].
Federici, JF ;
Schulkin, B ;
Huang, F ;
Gary, D ;
Barat, R ;
Oliveira, F ;
Zimdars, D .
SEMICONDUCTOR SCIENCE AND TECHNOLOGY, 2005, 20 (07) :S266-S280