Reactive extraction of zinc ions in the Scheibel column; A case study by applying the mathematical modelling of mass transfer with forward mixing

被引:13
作者
Shakib, Benyamin [1 ]
Torkaman, Rezvan [2 ]
Saremi, Mojtaba [3 ]
Torab-Mostaedi, Meisam [2 ]
Asadollahzadeh, Mehdi [2 ]
机构
[1] Sharif Univ Technol, Dept Energy Engn, POB 11365-8639, Tehran, Iran
[2] Nucl Sci & Technol Res Inst, Nucl Fuel Cycle Res Sch, POB 11365-8486, Tehran, Iran
[3] Amirkabir Univ Technol, Energy Engn & Phys Dept, POB 15875-4413, Tehran, Iran
关键词
Zn(II) extraction; Scheibel column; Chemical reaction system; Forward mixing model; DROP SIZE DISTRIBUTION; SOLVENT-EXTRACTION; TRANSFER COEFFICIENTS; MAXIMUM-ENTROPY; PREDICTION; HYDRODYNAMICS; PARAMETERS; SEPARATION; SYSTEMS; HOLDUP;
D O I
10.1016/j.cep.2021.108606
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An experimental and modeling study on the feasibility of the Scheibel extraction column is presented for heavy metal separation from chloride solution. In continuous experiments, the chemical reaction systems are considered zinc extraction by D2EHPA and stripping from the loaded organic phase by chloride solutions. The experimental results represent that the best extraction and stripping rates in the agitation speed of 155 rpm and the rate of inlet phases of 28 L/h are equal to 99.56% and 98.11%, respectively. The mass transfer modeling by applying the forward mixing is interpreted for solvent extraction systems in this column with the fitting technique. The calculated results from theoretical models compared with the experimental data, which good agreement was obtained using this model. The mathematical modeling on the reactive mass transfer data expresses that the axial dispersion coefficients based on the dispersed phase improve with increased agitation speed and dispersed phase rate. In contrast, these coefficients have an inverse relation with the continuous phase flow rate. This paper's experimental and numerical study provides beneficial information about the metallurgical industry to design solvent extraction columns.
引用
收藏
页数:12
相关论文
共 40 条
  • [1] Synergistic effect of MEHPA on co-extraction of zinc and cadmium with DEHPA
    Alamdari, EK
    Moradkhani, D
    Darvishi, D
    Askari, M
    Behnian, D
    [J]. MINERALS ENGINEERING, 2004, 17 (01) : 89 - 92
  • [2] MATHEMATICAL-MODELING AND STEADY-STATE ANALYSIS OF A SCHEIBEL EXTRACTION COLUMN
    ALATIQI, I
    ALY, G
    MJALLI, F
    MUMFORD, CJ
    [J]. CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1995, 73 (04) : 523 - 533
  • [3] CYANEX 272 for the extraction and recovery of zinc from aqueous waste solution using a mixer-settler unit
    Ali, AMI
    Ahmad, IM
    Daoud, JA
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2006, 47 (03) : 135 - 140
  • [4] Studies of Drop Behavior and Prediction of Sauter Mean Drop Diameter in Various Rotary Agitated Extraction Columns
    Asadollahzadeh, M.
    Torab-mostaedi, M.
    Torkaman, R.
    [J]. INTERNATIONAL JOURNAL OF ENGINEERING, 2016, 29 (08): : 1047 - 1055
  • [5] Assessment of mass transfer coefficients in extraction stages of La(III) and Ce(III) ions by using rotating Scheibel column with regular packing structure
    Asadollahzadeh, Mehdi
    Torkaman, Rezvan
    Torab-Mostaedi, Meisam
    Saremi, Mojtaba
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2021, 274
  • [6] Experimental and modeling investigation of cobalt ion extraction in multistage extractor: Efficient evaluation of mass transfer coefficients using forward mixing approach
    Asadollahzadeh, Mehdi
    Torkaman, Rezvan
    Torab-Mostaedi, Meisam
    Saremi, Mojtaba
    [J]. INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2021, 125
  • [7] Testing the Implementation of a Pilot-Scale Kuhni Column in Reactive and non-Reactive Condition
    Asadollahzadeh, Mehdi
    Torkaman, Rezvan
    Torab-Mostaedi, Meisam
    [J]. GEOSYSTEM ENGINEERING, 2021, 24 (02) : 88 - 100
  • [8] Continuous Extraction of Europium(III) by Ionic Liquid in the Rotating Disk Column with an Asymmetrical Structure Aimed at the Evaluation of Reactive Mass Transfer
    Asadollahzadeh, Mehdi
    Torkaman, Rezvan
    Torab-Mostaedi, Meisam
    [J]. ACS OMEGA, 2020, 5 (30): : 18700 - 18709
  • [9] Estimation of Performance with the Two Truncated Probability Density Functions, Case Study: Using Mixco Column to Extract Samarium and Gadolinium
    Asadollahzadeh, Mehdi
    Torkaman, Rezvan
    Torab-Mostaedi, Meisam
    Moazami, Farzad
    [J]. SEPARATION SCIENCE AND TECHNOLOGY, 2021, 56 (07) : 1241 - 1252
  • [10] Coupling minimum cross-entropy model with experimental data to determine the drop size distribution for lanthanum extraction in ARDC column
    Asadollahzadeh, Mehdi
    Torkaman, Rezvan
    Torab-Mostaedi, Meisam
    [J]. SEPARATION SCIENCE AND TECHNOLOGY, 2021, 56 (06) : 1071 - 1083