Operation of synchronous generator LOE protection in the presence of shunt-FACTS

被引:20
作者
Ghorbani, Amir [1 ]
Mozafari, Babak [1 ]
Soleymani, Soodabeh [1 ]
Ranjbar, Ali Mohammad [1 ]
机构
[1] Islamic Azad Univ, Dept Elect Engn, Sci & Res Branch, Tehran, Iran
关键词
Generator loss of excitation (LOE) protection; Flexible AC transmission system (FACTS); Static VAR compensator (SVC); Thyristor controlled reactor (TCR); Thyristor switched capacitor (TSC); Static synchronous compensator (STATCOM); DISTANCE PROTECTION; EXCITATION PROTECTION;
D O I
10.1016/j.epsr.2014.09.019
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper deals with the impact of shunt-FACTS devices on the synchronous generator loss of excitation (LOE) protection. Considered shunt-FACTS devices in this paper include the static VAR compensator (SVC) and static synchronous compensator (STATCOM). The SVC has been modeled by thyristor switched capacitor (TSC) and thyristor controlled reactor (TCR) branches. Also, 48-pulsed converter is used to model STATCOM. The LOE relay considered in this paper is a negative offset mho distance relay containing two zones. It has been shown that injected reactive power of by shunt-FACTS devices prevents from the generator voltage drop during LOE, which causes the operation of LOE relay to be delayed. It has been also shown that when an incomplete LOE occurs, the presence of shunt-FACTS devices leads to under-reach of the relay. In this paper, various operational conditions of the power system and shunt-FACTS devices have been surveyed to authenticate the results. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:178 / 186
页数:9
相关论文
共 21 条
[1]   Performance comparison of distance protection schemes for Shunt-FACTS compensated transmission lines [J].
Albasri, Fadhel A. ;
Sidhu, Tarlochan Singh ;
Varma, Rajiv K. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (04) :2116-2125
[2]   REMOVAL OF DC-OFFSET IN CURRENT WAVE-FORMS USING DIGITAL MIMIC FILTERING [J].
BENMOUYAL, G .
IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (02) :621-630
[3]   LOSS OF EXCITATION PROTECTION FOR MODERN SYNCHRONOUS GENERATORS [J].
BERDY, J .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, 94 (05) :1457-1463
[4]   INFLUENCE OF GENERATOR LOSS OF EXCITATION ON BULK POWER-SYSTEM RELIABILITY [J].
DARRON, HG ;
KOEPFINGER, JL ;
MATHER, JR ;
RUSCHE, PA .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1975, 94 (05) :1473-1483
[5]   Distance protection in the presence of unified power flow controller [J].
Dash, PK ;
Pradhan, AK ;
Panda, G .
ELECTRIC POWER SYSTEMS RESEARCH, 2000, 54 (03) :189-198
[6]   An Innovative Loss-of-Excitation Protection Based on the Fuzzy Inference Mechanism [J].
de Morais, Adriano P. ;
Cardoso, Ghendy, Jr. ;
Mariotto, L. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2010, 25 (04) :2197-2204
[7]   HYDRAULIC-TURBINE AND TURBINE CONTROL-MODELS FOR SYSTEM DYNAMIC STUDIES [J].
DEMELLO, FP ;
KOESSLER, RJ ;
AGEE, J ;
ANDERSON, PM ;
DOUDNA, JH ;
FISH, JH ;
HAMM, PAL ;
KUNDUR, P ;
LEE, DC ;
ROGERS, GJ ;
TAYLOR, C .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1992, 7 (01) :167-179
[8]   Operation of impedance protection relays with the STATCOM [J].
El-Arroudi, K ;
Joos, G ;
McGillis, DT .
IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (02) :381-387
[9]   Novel controllers for the 48-pulse VSCSTATCOM and SSSC for voltage regulation and reactive power compensation [J].
El-Moursi, MS ;
Sharaf, AM .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2005, 20 (04) :1985-1997
[10]   Application of the Posicast control method to static shunt compensators [J].
Ghorbani, Amir ;
Masoudi, Siamak ;
Shabani, Arash .
TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2012, 20 :1100-1108