Cyclic olefin copolymer based microfluidic devices for biochip applications: Ultraviolet surface grafting using 2-methacryloyloxyethyl phosphorylcholine

被引:46
作者
Jena, Rajeeb K. [1 ]
Yue, C. Y. [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Mfg Syst & Technol Programme, Singapore MIT Alliance, Singapore 639798, Singapore
来源
BIOMICROFLUIDICS | 2012年 / 6卷 / 01期
关键词
CAPILLARY-ELECTROPHORESIS; PHOSPHOLIPID POLYMERS; PROTEIN; CHIPS; MICROCHANNELS; COMPATIBILITY; IRRADIATION; MICROCHIPS; CELL; COC;
D O I
10.1063/1.3682098
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This report studies the surface modification of cyclic olefin copolymer (COC) by 2-methacryloyloxyethyl phosphorylcholine (MPC) monomer using photografting technique for the purpose of biointerface applications, which demonstrate resistance to both protein adsorption and cell adhesion in COC-based microfluidic devices. This is essential because the hydrophobic nature of COC can lead to adsorption of specific compounds from biological fluids in the microchannel, which can affect the results during fluidic analysis and cause clogging inside the microchannel. A correlation was found between the irradiation time and hydrophobicity of the modified substrate. Static water contact angle results show that the hydrophilicity property of the MPC-grafted substrate improves with increasing irradiation time. The contact angle of the modified surface decreased to 20 +/- 5 degrees from 88 +/- 63 degrees for the untreated substrate. The surface characterization of the modified surface was evaluated using x-ray photoelectron spectroscopy (XPS) and Fourier transform infrared spectroscopy (FTIR spectroscopy). Attenuated total reflection-FTIR and XPS results show the presence of the phosphate group (P-O) on modified COC substrates, indicating that the hydrophilic MPC monomer has successfully grafted on COC. Finally, it was demonstrated that cell adhesion and protein adsorption on the MPC modified COC specimen has reduced significantly. (C) 2012 American Institute of Physics. [doi:10.1063/1.3682098]
引用
收藏
页数:12
相关论文
共 37 条
[1]   Surface modification in microchip electrophoresis [J].
Belder, D ;
Ludwig, M .
ELECTROPHORESIS, 2003, 24 (21) :3595-3606
[2]   Thermoplastic microfluidic device for on-chip purification of nucleic acids for disposable diagnostics [J].
Bhattacharyya, A ;
Klapperich, CM .
ANALYTICAL CHEMISTRY, 2006, 78 (03) :788-792
[3]   Cell and protein compatibility of parylene-C surfaces [J].
Chang, Tracy Y. ;
Yadav, Vikramaditya G. ;
De Leo, Sarah ;
Mohedas, Agustin ;
Rajalingam, Birnal ;
Chen, Chia-Ling ;
Selvarasah, Selvapraba ;
Dokmeci, Mehmet R. ;
Khademhosseini, Ali .
LANGMUIR, 2007, 23 (23) :11718-11725
[4]   Wall coating for capillary electrophoresis on microchips [J].
Dolník, V .
ELECTROPHORESIS, 2004, 25 (21-22) :3589-3601
[5]  
Forsyth J, 2001, MACROMOL CHEM PHYSIC, V202, P614, DOI 10.1002/1521-3935(20010301)202:5<614::AID-MACP614>3.0.CO
[6]  
2-C
[7]   PDMS-based microfluidic devices for biomedical applications [J].
Fujii, T .
MICROELECTRONIC ENGINEERING, 2002, 61-2 :907-914
[8]   Characterizing electroosmotic flow in microfluidic devices [J].
Gaudioso, J ;
Craighead, HG .
JOURNAL OF CHROMATOGRAPHY A, 2002, 971 (1-2) :249-253
[9]  
Ishihara K, 1997, TRENDS POLYM SCI, V5, P401
[10]   SYNTHESIS OF PHOSPHOLIPID POLYMERS HAVING A METHANE BOND IN THE SIDE-CHAIN AS COATING MATERIAL ON SEGMENTED POLYURETHANE AND THEIR PLATELET ADHESION-RESISTANT PROPERTIES [J].
ISHIHARA, K ;
HANYUDA, H ;
NAKABAYASHI, N .
BIOMATERIALS, 1995, 16 (11) :873-879