Hydrogen peroxide biosensor based on the bioelectrocatalysis of myoglobin incorporated in multi-walled carbon nanotubes/chitosan composite film

被引:0
|
作者
Duan, Lian-Sheng [1 ,2 ]
Xu, Qiao [1 ]
Xie, Fen [1 ]
Wang, Sheng-Fu [1 ]
机构
[1] Hubei Univ, Coll Chem & Chem Engn, Wuhan 430062, Peoples R China
[2] Hubei Univ Educ, Dept Chem & Life Sci, Wuhan 430205, Peoples R China
来源
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE | 2008年 / 3卷 / 02期
关键词
direct electrochemistry; electrocatalysis; myoglobin; chitosan; MWNTs;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Myoglobin/multi-walled carbon nanotubes/chitosan film (Mb/MWNTs/Cs) electrodes were fabricated based on cross-linking myoglobin ( Mb) with multi-walled carbon nanotubes/chitosan (MWNTs/Cs) composite film coated on a glassy carbon electrode ( GCE). Direct electrochemistry and electrocatalysis of Mb on the Mb/MWNTs/Cs/GCE were studied. The Mb/MWNTs/Cs/GCE exhibited excellent electrocatalytic activity and rapid response for H2O2 in the absence of a mediator. The linear range of detection towards H2O2 was from 3.79 x 10(-5) to 5.50 x 10(-4) mol L-1 by the method of amperometric i-t curve. The Mb/MWNTs/Cs/GCE had good repeatability and stability for the determination of H2O2.
引用
收藏
页码:118 / 124
页数:7
相关论文
共 50 条
  • [1] Hydrogen Peroxide Biosensor Based on Myoglobin Immobilized on Silver Nanoparticles Decorated Oxidized Multi-Walled Carbon Nanotubes
    Liu, Benzhi
    Wang, Min
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2013, 8 (07): : 9801 - 9810
  • [2] A hydrogen peroxide biosensor based on the bioelectrocatalysis of hemoglobin incorporated in a kieselgubr film
    Wang, HY
    Guan, R
    Fan, CH
    Zhu, DX
    Li, GX
    SENSORS AND ACTUATORS B-CHEMICAL, 2002, 84 (2-3) : 214 - 218
  • [3] A nitric oxide biosensor based on myoglobin adsorbed on multi-walled carbon nanotubes
    Zhang, L
    Zhao, GC
    Wei, XW
    Yang, ZS
    ELECTROANALYSIS, 2005, 17 (07) : 630 - 634
  • [4] Composite film of carbon nanotubes and chitosan for preparation of amperometric hydrogen peroxide biosensor
    Qian, L
    Yang, XR
    TALANTA, 2006, 68 (03) : 721 - 727
  • [5] Hydrogen peroxide biosensor based on the bioelectrocatalysis of horseradish peroxidase incorporated in a new hydrogel film
    Sun, Yi-Xin
    Zhang, Jian-Tao
    Huang, Shi-Wen
    Wang, Sheng-Fu
    SENSORS AND ACTUATORS B-CHEMICAL, 2007, 124 (02) : 494 - 500
  • [6] Hydrogen peroxide biosensor based on gold nanoparticles/thionine/gold nanoparticles/multi-walled carbon nanotubes-chitosans composite film-modified electrode
    Li, Shenfeng
    Zhu, Xiaoying
    Zhang, Wei
    Xie, Guoming
    Feng, Wenli
    APPLIED SURFACE SCIENCE, 2012, 258 (07) : 2802 - 2807
  • [7] Electrochemical biosensor based on multi-walled carbon nanotubes and Au nanoparticles synthesized in chitosan
    Kang, Xinhuang
    Mai, Zhibin
    Zou, Xiaoyong
    Cai, Peixiang
    Mo, Jinyuan
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2007, 7 (4-5) : 1618 - 1624
  • [8] Imprinted Electrochemical Sensor of Tyrosine Based on Chitosan/β-Cyclodextrin/Multi-walled Carbon Nanotubes Composite Film
    Bai, Xiaopeng
    Wu, Ying
    Deng, Lili
    Gong, Li
    Xu, Tianchi
    Song, Wenbo
    Feng, Xun
    CURRENT ANALYTICAL CHEMISTRY, 2022, 18 (04) : 495 - 503
  • [9] Construction of Biosensor Based on Glassy Carbon Electrode Modified by Composite Film of Multi-Walled Carbon Nanotubes and Poly(ethylenimine)
    Sun, Tao
    Zheng, Haitao
    Li, Wei-wei
    Liu, Pu
    Ruan, Yanli
    Suye, Shin-ichiro
    ADVANCED MATERIAL SCIENCE AND TECHNOLOGY, PTS 1 AND 2, 2011, 675-677 : 235 - +
  • [10] Glucose Biosensor Based on Poly-Lithium Benzenetricarboxylic Acid and Multi-walled Carbon Nanotubes Composite Film
    Wang Tao-Yi
    Xu Fen
    Sun Li-Xian
    Zhang Jia-Ming
    Ru Hui-Ying
    Liu Ying-Ya
    Zheng Qian
    Zhang Jian
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (12) : 1832 - 1838