A novel calibration method for digital templating of total hip arthroplasty: a prospective clinical study of dual scale type single marker calibration in supine radiographs

被引:5
作者
Loweg, Lemmard [1 ]
Trost, Matthias [2 ]
Kutzner, Karl Philipp [1 ]
Ries, Christian [3 ]
Boese, Christoph Kolja [4 ]
机构
[1] St Josefs Hosp Wiesbaden, Dept Orthopaed Surg & Traumatol, Wiesbaden, Germany
[2] Ruhr Univ Bochum, St Josef Hosp, Dept Orthopaed & Traumatol, Bochum, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Dept Orthopaed, Hamburg, Germany
[4] Univ Hosp Cologne, Dept Orthopaed & Trauma Surg, Joseph Stelzmann Str 9, D-50924 Cologne, Germany
关键词
Digital templating; Total hip arthroplasty; Hip replacement; Calibration; Digital radiograph; MAGNIFICATION;
D O I
10.1007/s00264-020-04597-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background External calibration markers (ECM) are the standard of care for digital templating in joint replacements. Spherical mono markers are known to be unreliable. Fixed calibration factors (FCF) can reduce the overall error by placement of markers, but do not address individual patient anatomy. Dual scale calibration marker (DSCM) methods were developed to improve precision of calibration but require two markers. This prospective observational study is the first to analyse the application of a dual scale type single marker (DSSM) method in supine radiographs. Methods One hundred patients with unilateral total hip arthroplasty (THA) underwent anterior-posterior pelvis X-ray with ECM and DSSM. The femoral THA head components were used as internal reference (ICM). An empirical fixed calibration factor (FCF; 120%) was used as comparator. Absolute differences of ICM and both ECM and DSSM were calculated. Absolute relative deviations (ARD) were calculated. Results Mean absolute calibration factor differences of ECM, FCF and DSSM from ICM were 0.105 (0.002-0.182), 0.016 (0.082-0.013) and 0.011 (0.056-0.009), respectively. ARD differences between ECM and DSSM as well as FCF and DSSM were significant (p < 0.001). Conclusion The DSSM method showed superior results over ECM and FCF to predict the optimal calibration factor in supine radiographs. The novel DSSM method could be used to improve digital templating in supine radiographs without need for additional markers.
引用
收藏
页码:1693 / 1699
页数:7
相关论文
共 14 条
[1]   Prospective, Randomized, Surgeon-Blinded Comparison of Standard Magnification Assumption vs Magnification Marker Usage for Preoperative Templating in Total Hip Arthroplasty [J].
Archibeck, Michael J. ;
Tripuraneni, Krishna R. ;
Carothers, Joshua T. ;
Junick, Daniel W. ;
Munson, Natalie R. ;
Murray-Krezan, Cristina M. .
JOURNAL OF ARTHROPLASTY, 2017, 32 (10) :3061-3064
[2]  
Bleβ H.-H., 2017, Weiβbuch Gelenkersatz
[3]   Calibration Marker Position in Digital Templating of Total Hip Arthroplasty [J].
Boese, Christoph K. ;
Bredow, Jan ;
Dargel, Jens ;
Eysel, Peer ;
Geiges, Hansjoerg ;
Lechler, Philipp .
JOURNAL OF ARTHROPLASTY, 2016, 31 (04) :883-887
[4]   Influence of calibration on digital templating of hip arthroplasty [J].
Boese, Christoph Kolja ;
Wilhelm, Sebastian ;
Haneder, Stefan ;
Lechler, Philipp ;
Eysel, Peer ;
Bredow, Jan .
INTERNATIONAL ORTHOPAEDICS, 2019, 43 (08) :1799-1805
[5]   Dual-position calibration markers for total hip arthroplasty: theoretical comparison to fixed calibration and single marker method [J].
Boese, Christoph Kolja ;
Wilhelm, Sebastian ;
Haneder, Stefan ;
Lechler, Philipp ;
Eysel, Peer ;
Bredow, Jan .
INTERNATIONAL ORTHOPAEDICS, 2019, 43 (03) :589-595
[6]   Calibration Markers for Digital Templating in Total Hip Arthroplasty [J].
Boese, Christoph Kolja ;
Lechler, Philipp ;
Rose, Leonard ;
Dargel, Jens ;
Oppermann, Johannes ;
Eysel, Peer ;
Geiges, Hansjoerg ;
Bredow, Jan .
PLOS ONE, 2015, 10 (07)
[7]   Digital templating without a calibration marker is accurate at predicting implant size for hip hemiarthroplasty [J].
Derias, Mina ;
Khan, Muhammad A. ;
Buchanan, Jamie .
EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2020, 46 (01) :115-120
[8]  
Efe T, 2011, ACTA ORTHOP BELG, V77, P616
[9]   A comparison of four systems for calibration when templating for total hip replacement with digital radiography [J].
Franken, M. ;
Grimm, B. ;
Heyligers, I. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (01) :136-141
[10]   The Accuracy of Digital Templating in Uncemented Total Hip Arthroplasty [J].
Gamble, Patrick ;
de Beer, Justin ;
Petruccelli, Danielle ;
Winemaker, Mitchell .
JOURNAL OF ARTHROPLASTY, 2010, 25 (04) :529-532