Fabrication of Ti plus Mg composites by three-dimensional printing of porous Ti and subsequent pressureless infiltration of biodegradable Mg

被引:52
作者
Meenashisundaram, Ganesh Kumar [1 ]
Wang, Niyou [2 ]
Maskomani, Silambarasan [3 ]
Lu, Shenglu [1 ]
Anantharajan, Senthil Kumar [2 ]
Dheen, Shaikali Thameem [3 ]
Nai, Sharon Mui Ling [1 ]
Fuh, Jerry Ying Hsi [2 ]
Wei, Jun [1 ]
机构
[1] Singapore Inst Mfg & Technol, Addit Mfg Forming Technol Grp 3D, 73 Nanyang Dr, Singapore 637662, Singapore
[2] Natl Univ Singapore, Dept Mech Engn, 9 Engn Dr 1,07-08 Block EA, Singapore 117575, Singapore
[3] Natl Univ Singapore, Dept Anat, YLLSoM, 4 Med Dr,MD10, Singapore 117594, Singapore
来源
MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2020年 / 108卷
关键词
Ink jet 3D printing; Capillary mediated pressureless infiltration; Semi-degradable implant; Ti plus Mg composite; Porous Ti; Compression properties; Cytotoxicity; Net-shape fabrication; MECHANICAL-PROPERTIES; ORTHOPEDIC BIOMATERIALS; POWDER-METALLURGY; MAGNESIUM; TITANIUM; BONE; ALLOYS; SCAFFOLDS; IMPLANTS; FIBER;
D O I
10.1016/j.msec.2019.110478
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
A semi-degradable Ti + Mg composite with superior compression and cytotoxicity properties have been successfully fabricated using ink jet 3D printing followed by capillary mediated pressureless infiltration technique targeting orthopaedic implant applications. The composite exhibited low modulus (similar to 5.2 GPa) and high ultimate compressive strength (similar to 418 MPa) properties matching that of the human cortical bone. Ti + Mg composites with stronger 3D interconnected open-porous Ti networks are possible to be fabricated via 3D printing. Corrosion rate of samples measured through immersion testing using 0.9%NaCl solution at 37 degrees C indicate almost negligible corrosion rate for porous Ti (similar to 1.14 mu m/year) and < 1 mm/year for Ti + Mg composites for 5 days of immersion, respectively. The composite significantly increased the SAOS-2 osteoblastic bone cell proliferation rate when compared to the 3D printed porous Ti samples and the increase is attributed to the exogenous Mg2+ ions originating from the Ti + Mg samples. The cell viability results indicated absent to mild cytotoxicity. An attempt is made to discuss the key considerations for net-shape fabrication of Ti + Mg implants using ink jet 3D printing followed by infiltration approach.
引用
收藏
页数:16
相关论文
共 71 条
[31]   Influence of Binder Quantity on Dimensional Accuracy and Resilience in 3D-Printing [J].
Kafara, M. ;
Kemnitzer, J. ;
Westermann, H. -H. ;
Steinhilper, R. .
15TH GLOBAL CONFERENCE ON SUSTAINABLE MANUFACTURING, 2018, 21 :638-646
[32]   In vitro cytotoxicity of galvanically coupled magnesium-titanium particles on human osteosarcoma SAOS2 cells: A potential cancer therapy [J].
Kim, Jua ;
Gilbert, Jeremy L. .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2019, 107 (01) :178-189
[33]   Wettability of pure Ti by molten pure Mg droplets [J].
Kondoh, Katsuyoshi ;
Kawakami, Masashi ;
Imai, Hisashi ;
Umeda, Junko ;
Fujii, Hidetoshi .
ACTA MATERIALIA, 2010, 58 (02) :606-614
[34]   Low stiffness porous Ti structures for load-bearing implants [J].
Krishna, B. Vamsi ;
Bose, Susmita ;
Bandyopadhyay, Amit .
ACTA BIOMATERIALIA, 2007, 3 (06) :997-1006
[35]   Advances in metals and alloys for joint replacement [J].
Kuncicka, Lenka ;
Kocich, Radim ;
Lowe, Terry C. .
PROGRESS IN MATERIALS SCIENCE, 2017, 88 :232-280
[36]   Future clinical and economic impact of revision total hip and knee arthroplasty [J].
Kurtz, Steven M. ;
Ong, Kevin L. ;
Schmier, Jordana ;
Mowat, Fionna ;
Saleh, Khaled ;
Dybvik, Eva ;
Kaerrholm, Johan ;
Garellick, Goeran ;
Havelin, Leif I. ;
Furnes, Ove ;
Malchau, Henrik ;
Lau, Edmund .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A :144-151
[37]   Custom-designed orthopedic implants evaluated using finite element analysis of patient-specific computed tomography data: femoral-component case study [J].
La Harrysson, Ola ;
Hosni, Yasser A. ;
Nayfeh, Jamal F. .
BMC MUSCULOSKELETAL DISORDERS, 2007, 8
[38]   Do position and size matter? An analysis of cage and placement variables for optimum lordosis in PLIF reconstruction [J].
Landham, Priyan R. ;
Don, Angus S. ;
Robertson, Peter A. .
EUROPEAN SPINE JOURNAL, 2017, 26 (11) :2843-2850
[39]   Bone ingrowth in porous titanium implants produced by 3D fiber deposition [J].
Li, Jia Ping ;
Habibovic, Pamela ;
van den Doel, Mirella ;
Wilson, Clayton E. ;
de Wijn, Joost R. ;
van Blitterswijk, Clemens A. ;
de Groot, Klaas .
BIOMATERIALS, 2007, 28 (18) :2810-2820
[40]   Mechanical degradation of porous titanium with entangled structure filled with biodegradable magnesium in Hanks' solution [J].
Li, Qiuyan ;
Jiang, Guofeng ;
Wang, Cunlong ;
Dong, Jie ;
He, Guo .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2015, 57 :349-354