Two self-reinforced poly(L/DL)lactide 70: 30 or self-reinforced poly(L/DL)lactide 70: 30/ bioactive glass (SR-P(L/DL)LA/bioactive glass) composite rods (2 mm x 40 mm) were implanted into the dorsal subcutaneous tissue and osteotomies of the distal femur were fixed with these rods (2 mm x 26 mm) in 36 rabbits. The follow-up times varied from 3 to 100 weeks. After the animals were killed, three-point bending and shear tests and molecular weight measurements were performed for subcutaneously placed rods. Radiological, histological, histomorphometrical, microradiographic and oxytetracycline-fluorescence studies of the osteotomized and intact control femora were performed. After 12 weeks the SR-P(L/DL)LA rods had fragmented into pieces and the mechanical properties could not be measured. The SR-P(L/DL)LA/bioactive glass rods lost their mechanical properties slower, and at 24 weeks the bending strength had decreased by 39% and the shear strength by 50%. After that the mechanical properties of the SR-P(L/DL)LA/bioactive glass rods could not be measured. All osteotomies healed well, and no gross signs of inflammatory reactions were observed. One slight displacement was seen in the three-week follow-up group with SR-P(L/DL)LA rods. Signs of resorption of the implants were seen after 48 weeks in the SR-P(L/DL)LA group and after 24 weeks in the SR-P(L/DL)LA/bioactive glass group. The SR-P(L/DL)LA/bioactive glass rods were almost totally resorbed from the bone at 100 weeks. The present investigation showed that the mechanical strength and fixation properties of the SR-P(L/DL)LA and the SR-P(L/DL)LA/bioactive glass composite rods are suitable for fixation of cancellous bone osteotomies in rabbits.
引用
收藏
页码:725 / 744
页数:20
相关论文
共 50 条
  • [21] Strength retention of drawn self-reinforced polyglycolide rods and fixation properties of the distal femoral osteotomies with these rods. An experimental study on rats
    Harri Pihlajamäki
    E. Antero Mäkelä
    Nureddin Ashammakhi
    Janne Viljanen
    Hannu Pätiälä
    Pentti Rokkanen
    Timo Pohjonen
    Pertti Törmälä
    Antti Joukainen
    Journal of Materials Science: Materials in Medicine, 2002, 13 : 389 - 395
  • [22] ASSESSING THE POSSIBILITY OF MACHINING OF THE SELF-REINFORCED BIORESORBABLE POLYMER P(L/DL)LA 70:30
    Stares, Steferson Luiz
    Boehs, Lourival
    Fredel, Marcio Celso
    Aragones, Aguedo
    MACHINING SCIENCE AND TECHNOLOGY, 2011, 15 (04) : 392 - 414
  • [23] Self-Reinforced Bioresorbable Polymer P (L/DL) LA 70:30 for the Manufacture of Craniofacial Implant
    Stares, Steferson L.
    Boehs, Lourival
    Fredel, Marcio Celso
    Aragones, Aguedo
    Duek, Eliana A. R.
    POLIMEROS-CIENCIA E TECNOLOGIA, 2012, 22 (04): : 378 - 383
  • [24] Absorbable self-reinforced poly-L-lactide plates in the fixation of osteotomies of the distal femur with special reference to the site of implantation. An experimental study.
    Koskikare, K
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1999, 88 (01) : 79 - 80
  • [25] Healing of subcapital femoral osteotomies fixed with self-reinforced poly-L-lactide screws: an experimental long-term study in sheep
    Kirsi Jukkala-Partio
    Outi Laitinen
    Jarkko Vasenius
    Esa K. Partio
    Terttu Toivonen
    Pekka Tervahartiala
    Jaakko Kinnunen
    Pentti Rokkanen
    Archives of Orthopaedic and Trauma Surgery, 2002, 122 : 360 - 364
  • [26] Healing of subcapital femoral osteotomies fixed with self-reinforced poly-L-lactide screws: an experimental long-term study in sheep
    Jukkala-Partio, K
    Laitinen, O
    Vasenius, J
    Partio, EK
    Toivonen, T
    Tervahartiala, P
    Kinnunen, J
    Rokkanen, P
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (06) : 360 - 364
  • [27] Fixation of mandibular body osteotomies using biodegradable amorphous self-reinforced (70L:30DL) polylactide or metal lag screws:: an experimental study in sheep
    Kallela, I
    Tulamo, RM
    Hietanen, J
    Pohjonen, T
    Suuronen, R
    Lindqvist, C
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 1999, 27 (02) : 124 - 133
  • [28] Intramedullary fixation of distal femoral diaphyseal osteotomies with absorbable self-reinforced poly-L-lactide and metallic intramedullary rods assessed by plain radiographs, quantitative computed tomography, and magnetic resonance imaging: An experimental study in rabbits
    Viljanen, J
    Kinnunen, T
    Bondestam, S
    Rokkanen, P
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1998, 39 (02): : 222 - 228
  • [29] A retrospective evaluation of rigid fixation in orthognathic surgery using a biodegradable self-reinforced (70L:30DL) polyactide
    Mazzonetto, R
    Panza, AO
    Spagnoli, DB
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 33 (07) : 664 - 669
  • [30] COMPARISON OF ABSORBABLE SELF-REINFORCED POLY-L-LACTIDE SCREWS AND METALLIC SCREWS IN THE FIXATION OF MANDIBULAR CONDYLE OSTEOTOMIES - AN EXPERIMENTAL-STUDY IN SHEEP