Acute Outflow Obstruction of Hepatic Veins in Rabbits Quantitative Analysis of Hepatic Perfusion With Contrast-Enhanced Sonography

被引:6
作者
Kim, Kyoung Won [1 ]
Kim, Pyo Nyun [1 ]
Shin, Ji Hoon [1 ]
Shin, Dong Ho [3 ]
Jeong, Woo Kyoung [4 ]
Won, Hyung Jin [1 ]
Shin, Yong Moon [1 ]
Lee, Won Jae [5 ]
Lee, Moon Gyu [1 ]
Song, Gi-Won [2 ]
Hwang, Shin [2 ]
Lee, Sung-Gyu [2 ]
机构
[1] Univ Ulsan, Dept Radiol, Asan Med Ctr, Coll Med, Seoul 138736, South Korea
[2] Univ Ulsan, Dept Liver Transplantat Surg, Asan Med Ctr, Coll Med, Seoul 138736, South Korea
[3] Hanyang Univ, Guri Hosp, Res Inst Radiol, Guri, South Korea
[4] Hanyang Univ, Guri Hosp, Dept Radiol, Guri, South Korea
[5] Sungkyunkwan Univ, Dept Radiol, Samsung Med Ctr, Sch Med, Seoul, South Korea
关键词
animal study; contrast-enhanced sonography; hepatic venous obstruction; perfusion study; DONOR LIVER-TRANSPLANTATION; RIGHT LOBE GRAFT; COMPUTED-TOMOGRAPHY PERFUSION; DOPPLER WAVE-FORM; VENOUS CONGESTION; TRANSIT-TIME; ENDOVASCULAR TREATMENT; BALLOON ANGIOPLASTY; PORCINE MODEL; CT;
D O I
10.7863/jum.2011.30.5.635
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objectives-To compare time-enhancement curve parameters of contrast-enhanced sonography in acute partial hepatic venous outflow obstruction with those of a baseline study. Methods-Contrast-enhanced sonography was performed in 11 rabbits with bolus administration of a sulfur hexafluoride contrast agent (0.1 mL/kg). After baseline scanning for 3 minutes, a 5.3F balloon catheter was placed into the left hepatic vein. Obstruction was artificially induced by 0.4-mL balloon inflation, and sonography was repeatedly performed thereafter. On images stored with 1-second intervals, 2 x 2-mm regions of interest were placed, and mean luminosity was measured. Time-enhancement curves were plotted, and contrast arrival times, peak enhancement values, peak enhancement times, 50% wash-out times, and 3-minute wash-out rates were obtained. Paired t tests were performed to evaluate the significance of differences in the parameters between baseline and obstruction. Results-On baseline sonography, the median contrast arrival time, peak enhancement value, peak enhancement time, 50% wash-out time, and 3-minute wash-out rate were 6 (range, 4-8; mean SD, 5.9 +/- 1.2) seconds, 188.5 (104.7-209.5; 178.4 +/- 33.1) arbitrary units, 19 (14-27; 19.8 +/- 4.1) seconds, 75 (60-101; 78.2 +/- 13.9) seconds, and 89.7% (81.3%-95.1%; 88.4% +/- 4.9%), respectively. With obstruction, those values were 7(5-12; 6.9 +/- 2.3) seconds, 202.8 (98.2-215.1; 186.0 +/- 39.3) arbitrary units, 31 (17-59; 32 +/- 11.6) seconds, 101 (47-136; 96.2 +/- 23.6) seconds, and 79.2% (66.2%-88.8%; 79.1% +/- 7.6%). Compared with baseline, the peak enhancement time was significantly delayed from 19 to 31 seconds (P = .0027), 50% wash-out time significantly delayed from 75 to 101 seconds (P = .0209), and 3-minute wash-out rate significantly decreased from 89.7% to 79.2% (P < .0001) with obstruction, but there were no significant differences in contrast arrival times and peak enhancement values (P = .0756 and .2179). Conclusions-Contrast-enhanced sonography can provide quantitative assessment of microbubble congestion in partial hepatic venous outflow obstruction. The peak enhancement time and 50% wash-out time are delayed and 3-minute wash-out rate is decreased in rabbits with artificially induced obstruction compared with a baseline study.
引用
收藏
页码:635 / 642
页数:8
相关论文
共 28 条
[1]   Non-invasive diagnosis of hepatic cirrhosis by transit-time analysis of an ultrasound contrast agent [J].
Albrecht, T ;
Blomley, MJK ;
Cosgrove, DO ;
Taylor-Robinson, SD ;
Jayaram, V ;
Eckersley, R ;
Urbank, A ;
Butler-Barnes, J ;
Patel, N .
LANCET, 1999, 353 (9164) :1579-1583
[2]   Transit-time studies with Levovist in patients with and without hepatic cirrhosis: A promising new diagnostic tool [J].
Albrecht, T ;
Blomley, MJK ;
Cosgrove, DO ;
Taylor-Robinson, SD ;
Jayaram, V ;
Eckersley, R ;
Urbank, A ;
Butler-Barnes, J ;
Patel, N .
EUROPEAN RADIOLOGY, 1999, 9 (Suppl 3) :S377-S381
[3]   Aortic and hepatic contrast medium enhancement at CT part II. Effect of reduced cardiac output in a porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 207 (03) :657-662
[4]   Aortic and hepatic peak enhancement at CT: Effect of contrast medium injection rate - Pharmacokinetic analysis and experimental porcine model [J].
Bae, KT ;
Heiken, JP ;
Brink, JA .
RADIOLOGY, 1998, 206 (02) :455-464
[5]   Hepatic transit time of an echo enhancer:: an indicator of metastatic spread to the liver [J].
Bernatik, T ;
Becker, D ;
Neureiter, D ;
Hänsler, J ;
Frieser, M ;
Schaber, S ;
Wein, A ;
Hahn, EG ;
Strobel, D .
EUROPEAN JOURNAL OF GASTROENTEROLOGY & HEPATOLOGY, 2004, 16 (03) :313-317
[6]   Infusion versus bolus of an ultrasound contrast agent - In vivo dose-response measurements of BR1 [J].
Correas, JM ;
Burns, PN ;
Lai, XM ;
Qi, XL .
INVESTIGATIVE RADIOLOGY, 2000, 35 (01) :72-79
[7]  
Cosgrove D, 2006, ENHANCING THE ROLE OF ULTRASOUND WITH CONTRAST AGENTS, P3, DOI 10.1007/88-470-0476-4_1
[8]   Hepatic vein reconstruction in 152 living-related donor liver transplantation patients [J].
Egawa, H ;
Inomata, Y ;
Uemoto, S ;
Asonuma, K ;
Kiuchi, T ;
Okajima, H ;
Yamaoka, Y ;
Tanaka, K .
SURGERY, 1997, 121 (03) :250-257
[9]  
EGAWA H, 1993, CLIN TRANSPLANT, V7, P306
[10]   Right Hepatic Vein Stenosis at Anastomosis in Patients after Living Donor Liver Transplantation: Optimal Doppler US Venous Pulsatility Index and CT Criteria-Receiver Operating Characteristic Analysis [J].
Hwang, Hye Jeon ;
Kim, Kyoung Won ;
Jeong, Woo Kyoung ;
Song, Gi-Won ;
Ko, Gi-Young ;
Sung, Kyu Bo ;
Shin, Yong Moon ;
Kim, Pyo Nyun ;
Ha, Tae-Yong ;
Moon, Deok-Bog ;
Kim, Ki-Hun ;
Ahn, Chul-Soo ;
Hwang, Shin ;
Lee, Sung-Gyu .
RADIOLOGY, 2009, 253 (02) :543-551