Occlusal caries detection in primary teeth: a comparison of DIAGNOdent with conventional methods

被引:46
作者
Attrill, DC
Ashley, PF
机构
[1] Univ Manchester, Unit Prosthodont, Manchester M15 6FH, Lancs, England
[2] UCL Eastman Dent Inst, Dept Pediat Dent, London WC1X 8LD, England
关键词
D O I
10.1038/sj.bdj.4800998a
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objective To compare the accuracy and repeatability of three diagnostic systems (DIAGNOdent, visual and radiographic) for occlusal caries diagnosis in primary molars. Design Two examiner, in vitro, blinded study. Histological gold standard. Materials and methods 58 occlusal surfaces of primary molars examined in turn by two examiners using each of three diagnostic systems (DIAGNOdent, visual and radiographic). These results were compared with a histological gold standard. Sensitivity and specificity were calculated for each diagnostic system at a range of thresholds. Inter- and intra- examiner repeatability were calculated for each diagnostic system using the kappa statistic. Main outcome measures Sensitivity, specificity, inter and intra examiner repeatability for each diagnostic system. Results The highest sensitivity values were provided by DIAGNOdent (0.77 and 0.80, examiners 1 and 2 respectively) however this was offset by a lower specificity (0.82 and 0.85) than all other systems with the exception of examiner: 1 at V1 visual threshold. The DIAGNOdent gave the highest values of kappa for intra- and inter- examiner repeatability with the exception of intra-examiner repeatability for examiner 2 where visual diagnosis had the highest value of kappa. Conclusion The DIAGNOdent was the most accurate system tested for the detection of occlusal dentine caries in primary molars. The performance of the DIAGNOdent systems was not statistically significantly better than that achieved using visual examination for non-cavitated teeth (V1 and V2 threshold). DIAGNOdent may prove useful as a predictive clinical tool, however with appropriate training visual examination may offer similar results without the need for additional equipment.
引用
收藏
页码:440 / 443
页数:4
相关论文
共 5 条
[1]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[2]   Reproducibility and accuracy of three methods for assessment of demineralization depth on the occlusal surface: An in vitro examination [J].
Ekstrand, KR ;
Ricketts, DNJ ;
Kidd, EAM .
CARIES RESEARCH, 1997, 31 (03) :224-231
[3]   VISUAL AND RADIOGRAPHIC DIAGNOSIS OF OCCLUSAL CARIES IN 1ST PERMANENT MOLARS AND IN 2ND PRIMARY MOLARS [J].
KETLEY, CE ;
HOLT, RD .
BRITISH DENTAL JOURNAL, 1993, 174 (10) :364-370
[4]   Performance and reproducibility of a laser fluorescence system for detection of occlusal caries in vitro [J].
Lussi, A ;
Imwinkelried, S ;
Pitts, NB ;
Longbottom, C ;
Reich, E .
CARIES RESEARCH, 1999, 33 (04) :261-266
[5]  
MORTIMER K V, 1970, Caries Research, V4, P206