Directly suspended droplet three liquid phase microextraction of diclofenac prior to LC

被引:23
作者
Sarafraz-Yazdi, Ali [1 ,4 ]
Mofazzeli, Farideh [1 ,2 ]
Es'haghi, Zarrin [3 ,4 ]
机构
[1] Ferdowsi Univ Mashhad, Fac Sci, Dept Chem, Mashhad, Iran
[2] Islamic Azad Univ, Quchan Branch, Dept Chem, Quchan, Iran
[3] Payame Noor Univ, Fac Sci, Dept Chem, Tehran, Iran
[4] Ferdowsi Univ Mashhad, Biotechnol Res Ctr, Mashhad, Iran
关键词
column liquid chromatography; directly suspended droplet; liquid-liquid-liquid microextraction (LLLME); diclofenac; water analysis;
D O I
10.1365/s10337-007-0449-6
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Directly suspended droplet liquid-liquid-liquid microextraction (LLLME) has been used to determine residues of diclofenac (2-[2-(2,6-dichlorophenyl) aminophenyl] ethanoic acid), in environmental water samples. In this technique a free suspended droplet of an aqueous solvent is delivered to the top-center position of an immiscible organic solvent floating on the top of an aqueous sample while being agitated by a stirring bar placed on the bottom of the sample cell. Recently, diclofenac was found as an environmental contaminant in sewage, surface, ground and drinking water samples. In the present work, diclofenac was extracted from water samples by LLLME and analysed by HPLC with UV detection at 281 nm. Factors such as organic solvent, extraction and back extraction times, stirring rate and the pH of acceptor and donor phases were optimized. Enrichment factor and detection limit (LOD, n = 7) were 102 and 0.1 mu g L-1, respectively. The linearity ranged from 0.5 to 2,000 mu g(-1) with a %RSD (n = 5) of 7.2 at S/N = 3. All experiments were carried out at room temperature (22 +/- 0.5 degrees C).
引用
收藏
页码:49 / 53
页数:5
相关论文
共 40 条
[1]   Determination of drug residues in water by the combination of liquid chromatography or capillary electrophoresis with electrospray mass spectrometry [J].
Ahrer, W ;
Scherwenk, E ;
Buchberger, W .
JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (01) :69-78
[2]  
Alpendurada MD, 2000, J CHROMATOGR A, V889, P3
[3]   Spectrofluorimetric determination of diclofenac in the presence of α-cyclodextrin [J].
Arancibia, JA ;
Boldrini, MA ;
Escandar, GM .
TALANTA, 2000, 52 (02) :261-268
[4]   Application of strategic sample composition to the screening of anti-inflammatory drugs in water samples using solid-phase microextraction [J].
Carpinteiro, J ;
Quintana, JB ;
Martínez, E ;
Rodríguez, I ;
Carro, AM ;
Lorenzo, RA ;
Cela, R .
ANALYTICA CHIMICA ACTA, 2004, 524 (1-2) :63-71
[5]   Incomplete trapping in supported liquid membrane extraction with a stagnant acceptor for weak bases [J].
Chimuka, L ;
Megersa, N ;
Norberg, J ;
Mathiasson, L ;
Jönsson, JÅ .
ANALYTICAL CHEMISTRY, 1998, 70 (18) :3906-3911
[6]   Rapid and sensitive analysis of diclofenac in human plasma by GC/SIM/MS [J].
Choi, MH ;
Choi, YK ;
Chung, BC .
ANALYTICAL LETTERS, 1999, 32 (11) :2245-2253
[7]   Solid-phase microextraction for detemnining the distribution of sixteen US Environmental Protection Agency polycyclic aromatic hydrocarbons in water samples [J].
Doong, R ;
Chang, S ;
Sun, Y .
JOURNAL OF CHROMATOGRAPHY A, 2000, 879 (02) :177-188
[8]   From municipal sewage to drinking water: fate and removal of pharmaceutical residues in the aquatic environment in urban areas [J].
Heberer, T ;
Reddersen, K ;
Mechlinski, A .
WATER SCIENCE AND TECHNOLOGY, 2002, 46 (03) :81-88
[9]   Determination of diclofenac sodium by capillary zone electrophoresis with electrochemical detection [J].
Jin, WR ;
Zhang, J .
JOURNAL OF CHROMATOGRAPHY A, 2000, 868 (01) :101-107
[10]   AUTOMATED-SYSTEM FOR THE TRACE ANALYSIS OF ORGANIC-COMPOUNDS WITH SUPPORTED LIQUID MEMBRANES FOR SAMPLE ENRICHMENT [J].
JONSSON, JA ;
MATHIASSON, L ;
LINDEGARD, B ;
TROCEWICZ, J ;
OLSSON, AM .
JOURNAL OF CHROMATOGRAPHY A, 1994, 665 (02) :259-268