HIGH-PITCH SPIRAL USING THIRD-GENERATION DUAL-SOURCE WITH LOW TUBE VOLTAGE AND LOW CONCENTRATION OF CONTRAST AGENT IN CORONARY ANGIOGRAPHY-FEASIBILITY AND IMAGE QUALITY ANALYSIS

被引:0
作者
Meng, Xinyi [1 ]
机构
[1] Dalian Med Univ, Affiliated Hosp 1, Cardiac CT Examinat Dept, Dalian, Peoples R China
关键词
coronary artery computed tomography (CCTA); low iodine contrast agent; low radiation dose; image quality;
D O I
暂无
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
A11905
引用
收藏
页码:E190 / E190
页数:1
相关论文
共 40 条
  • [31] Ultra-low-dose CT coronary angiography using 128-slice dual source CT with low concentration contrast agent: initial experience
    Lei Zhao
    Aishi Liu
    Youmin Guo
    [J]. Japanese Journal of Radiology, 2017, 35 : 724 - 732
  • [32] Ultra-low-dose CT coronary angiography using 128-slice dual source CT with low concentration contrast agent: initial experience
    Zhao, Lei
    Liu, Aishi
    Guo, Youmin
    [J]. JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (12) : 724 - 732
  • [33] Influence of Contrast Agent Injection Scheme Customized by Dual-Source CT Based on Automatic Tube Voltage Technology on Image Quality and Radiation Dose of Coronary Artery Imaging
    He, Weiling
    Chen, Xin
    Hu, Rui
    Sun, Wenjie
    Tan, Weili
    [J]. FRONTIERS IN SURGERY, 2022, 9
  • [34] Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition
    Ghadri, Jelena R.
    Kueest, Silke M.
    Goetti, Robert
    Fiechter, Michael
    Pazhenkottil, Aju P.
    Nkoulou, Rene N.
    Kuhn, Felix P.
    Pietsch, Carsten
    von Schulthess, Patrick
    Gaemperli, Oliver
    Templin, Christian
    Kaufmann, Philipp A.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (05) : 1217 - 1225
  • [35] Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition
    Jelena R. Ghadri
    Silke M. Küest
    Robert Goetti
    Michael Fiechter
    Aju P. Pazhenkottil
    Rene N. Nkoulou
    Felix P. Kuhn
    Carsten Pietsch
    Patrick von Schulthess
    Oliver Gaemperli
    Christian Templin
    Philipp A. Kaufmann
    [J]. The International Journal of Cardiovascular Imaging, 2012, 28 : 1217 - 1225
  • [36] Feasibility of low-concentration iodinated contrast medium with lower-tube-voltage dual-source CT aortography using iterative reconstruction: comparison with automatic exposure control CT aortography
    Shin, Hee Jeong
    Kim, Song Soo
    Lee, Jae-Hwan
    Park, Jae-Hyeong
    Jeong, Jin-Ok
    Jin, Seon Ah
    Shin, Byung Seok
    Shin, Kyung-Sook
    Ahn, Moonsang
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 : S53 - S61
  • [37] Image quality of ultra-low radiation exposure coronary CT angiography with an effective dose <0.1 mSv using high-pitch spiral acquisition and raw data-based iterative reconstruction
    Annika Schuhbaeck
    Stephan Achenbach
    Christian Layritz
    Jasmin Eisentopf
    Franziska Hecker
    Tobias Pflederer
    Soeren Gauss
    Johannes Rixe
    Willi Kalender
    Werner G. Daniel
    Michael Lell
    Dieter Ropers
    [J]. European Radiology, 2013, 23 : 597 - 606
  • [38] Automated Tube Voltage Adaptation in Combination with Advanced Modeled Iterative Reconstruction in Thoracoabdominal Third-Generation 192-Slice Dual-Source Computed Tomography: Effects on Image Quality and Radiation Dose
    Scholtz, Jan-Erik
    Wichmann, Julian L.
    Huesers, Kristina
    Beeres, Martin
    Nour-Eldin, Nour-Eldin Abdelrehim
    Frellesen, Claudia
    Vogl, Thomas J.
    Lehnert, Thomas
    [J]. ACADEMIC RADIOLOGY, 2015, 22 (09) : 1081 - 1087
  • [39] Image quality of ultra-low radiation exposure coronary CT angiography with an effective dose &lt;0.1 mSv using high-pitch spiral acquisition and raw data-based iterative reconstruction
    Schuhbaeck, Annika
    Achenbach, Stephan
    Layritz, Christian
    Eisentopf, Jasmin
    Hecker, Franziska
    Pflederer, Tobias
    Gauss, Soeren
    Rixe, Johannes
    Kalender, Willi
    Daniel, Werner G.
    Lell, Michael
    Ropers, Dieter
    [J]. EUROPEAN RADIOLOGY, 2013, 23 (03) : 597 - 606
  • [40] Coronary angiography using second-generation dual source computed tomography Feasibility of low dose and low flow rate to achieve appropriate individual contrast enhancement using a test bolus-based contrast medium protocol-A CONSORT compliant article
    Zhu, Xiaomei
    Yu, Yusheng
    Xu, Dinghu
    Zhang, Hong
    Tang, Lijun
    [J]. MEDICINE, 2018, 97 (29)