A cadaver model evaluating femoral intramedullary reaming: a comparison between new reamer design (Pressure Sentinel) and a novel suction/irrigation reamer (RIA)

被引:8
作者
Goplen, Gordon [1 ]
Wilson, Janie Astephen [2 ]
Mcaffrey, Michael [3 ]
Deluzio, Kevin [4 ]
Leighton, Ross [5 ]
机构
[1] Univ Alberta, Fac Med, Div Orthoped Surg, Edmonton, AB, Canada
[2] Dalhousie Univ, Sch Biomed Engn, Halifax, NS, Canada
[3] Grace Hosp, Hotel Dieu, Windsor, ON, Canada
[4] Queens Univ, Fac Appl Sci Mech & Mat Engn, Kingston, ON, Canada
[5] Dalhousie Univ, Fac Med, Div Orthoped Surg, Halifax, NS, Canada
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2010年 / 41卷
关键词
Intramedullary; Pressure; Reamer; Reaming; Femur; Nailing; Irrigator; Aspirator; RIA; FAT INTRAVASATION; CORTICAL TEMPERATURE; MEDULLARY PRESSURE; MULTIPLE TRAUMA; SHEEP MODEL; INCREASE; EMBOLISM; CAVITY; FEMUR; HEAT;
D O I
10.1016/S0020-1383(10)70007-3
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare the intramedullary pressures developed during reaming of cadaveric femurs with the Synthes Reamer/Irrigator/Aspirator (RIA) reamer and the Zimmer Pressure Sentinel (PS) reamer, controlling for the force and speed of reaming. Method: Fifteen matched pairs of frozen unpreserved femurs were used in the study. Two pressure transducers and two thermocouples were screwed into holes drilled into the femoral shaft. The femurs were stabilized in the vertical position by mechanically attaching them to a custom jig equipped with a load cell to detect the vertical component of force applied to the reamer. Proximally a linear voltage displacement transducer (LVDT) was attached to the reamer to record the continuous position of the reamer. All femurs were reamed to a diameter 2mm larger than the narrowest point of the canal. Proximal and distal pressures, proximal and distal temperatures, applied vertical force and displacement were measured continuously throughout the reaming process. Maximum and minimum, and average proximal and distal pressures for each reamer were obtained and compared using paired t-tests. Averages were also calculated and compared in the same manner. A p-value of <0.05 was considered statistically significant. Results: The maximum, minimum and average intramedullary pressures during reaming were significantly lower with the RIA system than the PS reamer. In general, the pressures produced by the RIA system were consistently below atmospheric pressure for the majority of the reaming time. This was not true for the PS system. No appreciable temperature changes were observed during any of the trials. Conclusion: The RIA reaming system significantly reduces the intramedullary pressures produced during the reaming process compared to the PS reaming system. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:S38 / S42
页数:5
相关论文
共 43 条
[1]   Randomized Trial of Reamed and Unreamed Intramedullary Nailing of Tibial Shaft Fractures [J].
Bhandari, Mohit ;
Guyatt, Gordon ;
Tornetta, Paul, III ;
Schemitsch, Emil H. ;
Swiontkowski, Marc ;
Sanders, David ;
Walter, Stephen D. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (12) :2567-2578
[2]   Amplified Inflammatory Response to Sequential Hemorrhage, Resuscitation, and Pulmonary Fat Embolism An Animal Study [J].
Blankstein, Michael ;
Byrick, Robert J. ;
Nakane, Masaki ;
Bang, K. W. Annie ;
Freedman, John ;
Richards, Robin R. ;
Kajikawa, Osamu ;
Zdero, Rad ;
Bell, David ;
Schemitsch, Emil H. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2010, 92A (01) :149-161
[3]   Adult respiratory distress syndrome, pneumonia, and mortality following thoracic injury and a femoral fracture treated either with intramedullary nailing with reaming or with a plate - A comparative study [J].
Bosse, MJ ;
MacKenzie, EJ ;
Riemer, BL ;
Brumback, RJ ;
McCarthy, ML ;
Burgess, AR ;
Gens, DR ;
Yasui, Y .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (06) :799-809
[4]  
Brumback R J, 2000, J Am Acad Orthop Surg, V8, P83
[5]  
DANCKWARDTLILLI.G, 1969, ACTA ORTHOP SCAND S, V128, pS5
[6]   TEMPERATURE THRESHOLD LEVELS FOR HEAT-INDUCED BONE TISSUE-INJURY - A VITAL-MICROSCOPIC STUDY IN THE RABBIT [J].
ERIKSSON, AR ;
ALBREKTSSON, T .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (01) :101-107
[7]   Reaming during anterograde femoral nailing: is it worth it? [J].
Forster, MC ;
Aster, AS ;
Ahmed, S .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2005, 36 (03) :445-449
[8]   Surgical techniques: how I do it? The Reamer/Irrigator/Aspirator (RIA) System [J].
Giannoudis, P. V. ;
Tzioupis, C. ;
Green, J. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2009, 40 (11) :1231-1236
[9]  
Giannoudis PV, 2006, INJURY, V37, pS1, DOI 10.1016/j.injury.2006.08.018
[10]  
HEIM D, 1993, INJURY S10, V23, pS56