Direct electrochemistry of glucose oxidase immobilized on carbon nanotube for improving glucose sensing

被引:59
作者
Hyun, Kyuhwan [1 ]
Han, Sang Won [2 ]
Koh, Won-Gun [2 ]
Kwon, Yongchai [1 ]
机构
[1] Seoul Natl Univ Sci & Technol, Grad Sch Energy & Environm, Seoul 139743, South Korea
[2] Yonsei Univ, Dept Biomol & Chem Engn, Seoul 120749, South Korea
基金
新加坡国家研究基金会;
关键词
Enzyme immobilization structure; Physical adsorption; Glucose oxidase; Electron transfer rate constant; Glucose oxidation reaction; Enzyme stability; DIRECT ELECTRON-TRANSFER; LAYER-BY-LAYER; BIOSENSOR;
D O I
10.1016/j.ijhydene.2014.12.019
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this research, we suggest an enzyme immobilization structure that glucose oxidase (GOx) is coated on carbon nanotube (CNT) and quantify an optimal condition for the immobilization. Physical adsorption of GOx to CNT is used as the method for GOx immobilization on CNT (GOx/CNT). Cyclic voltammetry (CV) is served to evaluate catalytic activity and direct electrochemistry, while SEM is used to confirm the formation of GOx/CNT. To investigate the catalytic activity and the optimal loading of GOx, its peak current and electron transfer rate constant, k(s), are measured. In both ways, 2 mg mL(-1) GOx shows best results and its ks is 1.14s(-1). From the relationship between scan rate and peak current, it is also revealed that this structure is (i) controlled by surface reaction and (ii) quasireversible. Regarding redox reaction of GOx, peak potential is linearly varied with pH with slope of -51 mV/pH. The slope indicates a typical two-electron reaction that is a desirable reaction pathway. GOx-catalyzed glucose oxidation reaction (GOR) is also investigated by reacting different concentrations of glucose with GOx/CNT layer. Peak,current for GOR linearly increases with glucose concentration, proving that increase in glucose concentration promotes GOR. Therefore, GOx/CNT leads to high sensitivity of glucose (53.5 mu AmM(-1)cm(-2)). When it comes to long term stability, activity of GOx/CNT is measured and 86% of the activity is maintained even after two weeks, indicating that long term stability of GOx is excellent. (C) 2014, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:2199 / 2206
页数:8
相关论文
共 31 条
[1]   Increasing protein stability through control of the nanoscale environment [J].
Asuri, Prashanth ;
Karajanagi, Sandeep S. ;
Yang, Hoichang ;
Yim, Tae-Jin ;
Kane, Ravi S. ;
Dordick, Jonathan S. .
LANGMUIR, 2006, 22 (13) :5833-5836
[2]   Electrocatalysis at graphite and carbon nanotube modified electrodes: edge-plane sites and tube ends are the reactive sites [J].
Banks, CE ;
Davies, TJ ;
Wildgoose, GG ;
Compton, RG .
CHEMICAL COMMUNICATIONS, 2005, (07) :829-841
[3]   Direct electron transfer of glucose oxidase promoted by carbon nanotubes [J].
Cai, CX ;
Chen, J .
ANALYTICAL BIOCHEMISTRY, 2004, 332 (01) :75-83
[4]   Glucose microbiosensor based on alumina sol-gel matrix/electropolymerized composite membrane [J].
Chen, XH ;
Hu, YB ;
Wilson, GS .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :1005-1013
[5]   Deglycosylation of Glucose Oxidase for Direct and Efficient Glucose Electrooxidation on a Glassy Carbon Electrode [J].
Courjean, Olivier ;
Gao, Feng ;
Mano, Nicolas .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2009, 48 (32) :5897-5899
[6]   Probing electrical transport in nanomaterials: Conductivity of individual carbon nanotubes [J].
Dai, HJ ;
Wong, EW ;
Lieber, CM .
SCIENCE, 1996, 272 (5261) :523-526
[7]   A sensitive and stable biosensor based on the direct electrochemistry of glucose oxidase assembled layer-by-layer at the multiwall carbon nanotube-modified electrode [J].
Deng, Chunyan ;
Chen, Jinhua ;
Nie, Zhou ;
Si, Shihui .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (01) :213-219
[8]   Amperometric glucose biosensors based on Prussian Blue- and polyaniline-glucose oxidase modified electrodes [J].
Garjonyte, R ;
Malinauskas, A .
BIOSENSORS & BIOELECTRONICS, 2000, 15 (9-10) :445-451
[9]   Direct electron transfer of glucose oxidase on carbon nanotubes [J].
Guiseppi-Elie, A ;
Lei, CH ;
Baughman, RH .
NANOTECHNOLOGY, 2002, 13 (05) :559-564
[10]   Direct electron transfer of glucose oxidase and biosensing of glucose on hollow sphere-nanostructured conducting polymer/metal oxide composite [J].
Guo, Chun Xian ;
Li, Chang Ming .
PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2010, 12 (38) :12153-12159