Development of a novel optical CT employing a laser to create a collimated line-source with a flat-top intensity distribution

被引:10
作者
Cheng, Hong-Wen [2 ]
Ho, Ching-Ju [2 ]
Lee, Chung-Chi [1 ]
Tu, Shu-Ju [1 ]
Shih, Bor-Yuan [1 ]
Chao, Tsi-Chian [1 ]
机构
[1] Chang Gung Univ, Dept Med Imaging & Radiol Sci, Tao Yuan 333, Taiwan
[2] Natl Taipei Univ Educ, Dept Natl Sci Educ, Taipei, Taiwan
关键词
Optical CT; Polymer gel; 3D dosimetry; RADIATION-DOSE DISTRIBUTIONS; POLYMER-GEL; DOSIMETRY; SCANNER; MRI; RECONSTRUCTION; VERIFICATION; THERAPY;
D O I
10.1016/j.radmeas.2011.05.032
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In order to improve the scanning efficiency of commercial optical computed tomography (OptCT) scanners which use a conventional scanning laser, a novel optical CT scanner is being developed which employs a laser-based line source for the gel-scanning process. This line-source laser system can generate a uniform and parallel illumination profile in a line pattern, and consists of a Gaussian spot laser, a beam shaping module to convert a Gaussian laser beam into a 90 degrees fan-angle line pattern with flat-top profile, and a set of cylindrical lenses which converts the rays into parallel light. The optical CT scanner consists of a gel cylinder mounted inside the scanning tank, two scanning motors to operate the rotations and translations of the gel cylinder, and a CCD detector to record the image data. We present our analysis of the sources of uncertainty and evaluate the basic performance parameters of the optical CT scanner in conjunction with polymer gel dosimeters. To improve dose accuracy of this prototype, it may also be necessary to decrease the wall thicknesses of both the gel container and the matching liquid tank and more precisely to match the refractive indices of the whole system. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1932 / 1935
页数:4
相关论文
共 18 条
[1]   Experimental procedure for the manufacture and calibration of polyacrylamide gel (PAG) for magnetic resonance imaging (MRI) radiation dosimetry [J].
Baldock, C ;
Burford, RP ;
Billingham, N ;
Wagner, GS ;
Patval, S ;
Badawi, RD ;
Keevil, SF .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (03) :695-702
[2]   Use of Normoxic Polymer Gel On Dose Verification of 3.1-,4-,6-Mm Cones for Stereotactic Radiosurgery [J].
Chao, T. ;
Wu, J. ;
Chu, C. ;
Lee, C. ;
Wey, S. ;
Liu, H. ;
Tung, C. .
MEDICAL PHYSICS, 2008, 35 (06)
[3]  
De Deene Yves, 2009, Journal of Physics: Conference Series, V164, DOI 10.1088/1742-6596/164/1/012033
[4]   Three-dimensional dosimetry using polymer gel and magnetic resonance imaging applied to the verification of conformal radiation therapy in head-and-neck cancer [J].
De Deene, Y ;
De Wagter, C ;
Van Duyse, B ;
Derycke, S ;
De Neve, W ;
Achten, E .
RADIOTHERAPY AND ONCOLOGY, 1998, 48 (03) :283-291
[5]   A CCD-based optical CT scanner for high-resolution 3D imaging of radiation dose distributions: equipment specifications, optical simulations and preliminary results [J].
Doran, SJ ;
Koerkamp, KK ;
Bero, MA ;
Jenneson, P ;
Morton, EJ ;
Gilboy, WB .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (12) :3191-3213
[6]   Polymer gels for magnetic resonance imaging of radiation dose distributions at normal room atmosphere [J].
Fong, PM ;
Keil, DC ;
Does, MD ;
Gore, JC .
PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (12) :3105-3113
[7]   Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels .1. Development of an optical scanner [J].
Gore, JC ;
Ranade, M ;
Maryanski, MJ ;
Schulz, RJ .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (12) :2695-2704
[8]   Optical CT reconstruction of 3D dose distributions using the ferrous-benzoic-xylenol (FBX) gel dosimeter [J].
Kelly, RG ;
Jordan, KJ ;
Battista, JJ .
MEDICAL PHYSICS, 1998, 25 (09) :1741-1750
[9]   Focusing optics of a parallel beam CCD optical tomography apparatus for 3D radiation gel dosimetry [J].
Krstajic, Nikola ;
Doran, Simon J. .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (08) :2055-2075
[10]   Radiation dose distributions in three dimensions from tomographic optical density scanning of polymer gels .2. Optical properties of the BANG polymer gel [J].
Maryanski, MJ ;
Zastavker, YZ ;
Gore, JC .