Assessment of coronary artery bypass graft patency by multidetector computed tomography and electron-beam tomography

被引:1
作者
Piers, LH
Dorgelo, J
Tio, RA
Jessurun, GAJ
Oudkerk, M
Zijlstra, F
机构
[1] Univ Groningen Hosp, Dept Cardiol, NL-9700 RB Groningen, Netherlands
[2] Univ Groningen Hosp, Dept Radiol, NL-9700 RB Groningen, Netherlands
关键词
angiography; bypass; computed tomography; imaging;
D O I
10.1007/s10554-004-6136-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
This case report describes the use of retrospectively ECG-gated 16-slice multidetector computed tomography (MDCT) and electron-beam tomography (EBT) for assessing bypass graft patency in two patients with recurrent angina after coronary artery bypass graft surgery. The results of each tomographic modality were compared to the findings of traditional coronary angiography. In the first patient MDCT showed occlusion of the left internal mammary artery (LIMA) and saphenous vein graft after the second anastomosis. Coronary angiography confirmed these findings. In the second patient EBT showed patency of the LIMA and saphenous vein graft. After the first anastomosis of the saphenous vein graft, the connected vessel filled poorly. Coronary angiography confirmed both grafts to be patent, and detected an occlusion distal to the first anastomosis. These findings support the evidence that both MDCT and EBT are suitable techniques for establishing bypass graft patency by non-invasive means.
引用
收藏
页码:447 / 451
页数:5
相关论文
共 16 条
[1]   Noninvasive, three-dimensional visualization of coronary artery bypass grafts by electron beam tomography [J].
Achenbach, S ;
Moshage, W ;
Ropers, D ;
Nossen, J ;
Bachmann, K .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 79 (07) :856-861
[2]   Comparison of image quality in contrast-enhanced coronary artery visualization by electron beam tomography and retrospectively electrocardiogram-gated multislice spiral computed tomography [J].
Achenbach, S ;
Giesler, T ;
Ropers, D ;
Ulzheimer, S ;
Anders, K ;
Wenkel, E ;
Pohle, K ;
Kachelriess, M ;
Derlien, H ;
Kalender, WA ;
Daniel, WG ;
Bautz, W ;
Baum, U .
INVESTIGATIVE RADIOLOGY, 2003, 38 (02) :119-128
[3]   Clinical utility of computed tomography and magnetic resonance techniques for noninvasive coronary angiography [J].
Budoff, MJ ;
Achenbach, S ;
Duerinckx, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 42 (11) :1867-1878
[4]   Non-invasive evaluation of coronary artery bypass grafts using multi-slice computed tomography: initial clinical experience [J].
Burgstahler, C ;
Kuettner, A ;
Kopp, AF ;
Herdeg, C ;
Martensen, J ;
Claussen, CD ;
Schroeder, S .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2003, 90 (2-3) :275-280
[5]   Isotropic half-millimeter angiography of coronary artery bypass grafts with 16-slice computed tomography [J].
Dewey, M ;
Lembcke, A ;
Enzweiler, C ;
Hamm, B ;
Rogalla, P .
ANNALS OF THORACIC SURGERY, 2004, 77 (03) :800-804
[6]   Quantitative parameters of image quality in multidetector spiral computed tomographic coronary imaging with submillimeter collimation [J].
Ferencik, M ;
Moselewski, F ;
Ropers, D ;
Hoffmann, U ;
Baum, U ;
Anders, K ;
Pomerantsev, EV ;
Abbara, S ;
Brady, TJ ;
Achenbach, S .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (11) :1257-1262
[7]   Noninvasive evaluation of arterial grafts with newly released multidetector computed tomography [J].
Gurevitch, J ;
Gaspar, T ;
Orlov, B ;
Amar, R ;
Dvir, D ;
Peled, N ;
Aravot, DJ .
ANNALS OF THORACIC SURGERY, 2003, 76 (05) :1523-1527
[8]   Noninvasive evaluation of coronary artery bypass graft patency using three-dimensional angiography obtained with contrast-enhanced electron beam CT [J].
Ha, JW ;
Cho, SY ;
Shim, WH ;
Chung, N ;
Jang, Y ;
Lee, HM ;
Choe, KO ;
Chung, WJ ;
Choi, SH ;
Yoo, KJ ;
Kang, MS .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 172 (04) :1055-1059
[9]   Evaluation of coronary artery bypass graft patency using three-dimensional reconstruction and flow study on electron beam tomography [J].
Lu, B ;
Dai, RP ;
Jing, BL ;
Bai, H ;
He, S ;
Zhuang, N ;
Wu, QY ;
Budoff, MJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (05) :663-670
[10]  
MONCADA R, 1980, NEW ENGL J MED, V303, P503, DOI 10.1056/NEJM198008283030907