Investigation of entrainment behavior and characteristics of gas-liquid ejectors based on CFD simulation

被引:53
作者
Li, C. [1 ]
Li, Y. Z. [1 ]
机构
[1] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Xian 710049, Peoples R China
关键词
Gas-liquid ejector; Multiphase flow; Gas; CFD simulation; Optimization; Working fluids; COMPUTATIONAL FLUID-DYNAMICS; 2-PHASE FLOW DYNAMICS; STEAM-EJECTOR; PERFORMANCE PREDICTION; LOOP REACTORS; SYSTEM; REFRIGERATOR; OPERATION; VALIDATION; INJECTORS;
D O I
10.1016/j.ces.2010.10.041
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The aim of this paper is to investigate the entrainment behavior and performance of gas-liquid ejectors. computational fluid dynamics(CFD) model and the corresponding algorithm are developed and validation experiment has been carried out over a wide range of operation conditions for ejector with different configurations. Good agreement has been achieved between the predicted values from CFD simulation and the actual data by experimental measurement. The flow patterns that occur within the primary nozzle region are analyzed on the basis of one-dimensional isentropic compressible flow theory. The fluid pairs, consisting of the motive and the entrained fluids, are considered during the investigation with N(2)-H(2)O and He-LO(2) selected as the representative fluids. The investigation results indicate that for fixed primary flow and secondary flow pressures (P(P) and P(S), respectively), the entrained mass flow rate m(S) decreases linearly with the increasing pressure difference Delta P, while for fixed Delta P and secondary flow pressure P(S), the entrainment rate m(S) monotonically increases with an increase in primary flow pressure P(P) until a constant value is reached. Moreover, the mixing tube length has proven to be an important design parameter and can exert a remarkable influence on ejector performance. The optimum mixing tube length of gas-liquid ejector is about 1-2 times the mixing tube diameter, and deviation from the optimum value can dramatically degrade its entrainment performance. In other words, an obvious peak value of entrainment ratio appears at the optimum L/D. However, the optimum value of L/D for single-phase ejector happens in the range of 5-7, which differs significantly from that of gas-liquid ejector. Moreover, an inapparent effect has been observed when the mixing tube of single-phase ejector is longer than the optimum value. A detailed description of this phenomenon is presented in this paper. The conclusions of the research can be served as a guideline for ejector design. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:405 / 416
页数:12
相关论文
共 35 条
[1]  
[Anonymous], 1977, APPL MATH SCI
[2]   A small capacity steam-ejector refrigerator: experimental investigation of a system using ejector with movable primary nozzle [J].
Aphornratana, S ;
Eames, IW .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1997, 20 (05) :352-358
[3]   Experimental investigation of an ejector refrigerator: Effect of mixing chamber geometry on system performance [J].
Aphornratana, S ;
Chungpaibulpatana, S ;
Srikhirin, P .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2001, 25 (05) :397-411
[4]   t-3,t-5-Dimethyl-r-2,c-6-diphenyl-piperidin-4-one [J].
Balamurugan, S. ;
Thiruvalluvar, A. ;
Manimekalai, A. ;
Jayabharathi, J. .
ACTA CRYSTALLOGRAPHICA SECTION E-CRYSTALLOGRAPHIC COMMUNICATIONS, 2007, 63 :O3504-U3444
[5]  
Bando Y., 1990, INT CHEM ENG, V30, P729
[6]   Numerical assessment of ejector operation for refrigeration applications based on CFD [J].
Bartosiewicz, Y ;
Aidoun, Z ;
Mercadier, Y .
APPLIED THERMAL ENGINEERING, 2006, 26 (5-6) :604-612
[7]   An experimental investigation of a steam ejector refrigerator: the analysis of the pressure profile along the ejector [J].
Chunnanond, K ;
Aphornratana, S .
APPLIED THERMAL ENGINEERING, 2004, 24 (2-3) :311-322
[8]   A model for calculation of steam injector performance [J].
Deberne, N ;
Leone, JF ;
Duque, A ;
Lallemand, A .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1999, 25 (05) :841-855
[9]   MASS-TRANSFER IN JET LOOP REACTORS [J].
DIRIX, CAMC ;
VANDERWIELE, K .
CHEMICAL ENGINEERING SCIENCE, 1990, 45 (08) :2333-2340
[10]   A THEORETICAL AND EXPERIMENTAL-STUDY OF A SMALL-SCALE STEAM JET REFRIGERATOR [J].
EAMES, IW ;
APHORNRATANA, S ;
HAIDER, H .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (06) :378-386