In vitro and in vivo study of ion-implanted collagen for the substrate of small diameter artificial grafts

被引:9
作者
Kurotobi, K
Suzuki, Y
Kaibara, M
Iwaki, M
Nakajima, H
Suzuki, H
机构
[1] RIKEN, Surface Characterizat Ctr, Inst Phys & Chem Res, Wako, Saitama 3510198, Japan
[2] Sci Univ Tokyo, Fac Sci, Tokyo 162, Japan
[3] Teikyo Univ, Sch Med, Dept Surg 2, Tokyo 173, Japan
[4] Tokyo Metropolitan Inst Med Sci, Pharmaceut R&D Ctr, Tokyo 113, Japan
关键词
collagen; antithrombogenicity; platelet adhesion; washed platelet; ion implantation; artificial vascular graft;
D O I
10.1046/j.1525-1594.2003.07016.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Ion implantation into the collagen-coated inner surface of the grafts was performed and evaluated in vitro and in vivo to develop small diameter artificial vascular grafts. He+ ion implanted collagen-coated grafts with a fluence of 1 x 10(14) ions/cm(2) inhibited platelet adhesion and demonstrated patency for 240 days in an animal study. The platelet adhesion test using platelet rich plasma (PRP) showed antithrombogenicity at the fluence of 1 x 10(14) ions/cm(2) . Washed platelet adhesion test showed thrombus formation at the fluence of 1 x 10(14) ions/cm(2) . The results suggested that plasma protein adsorption onto the ion-implanted collagen significantly improved performance of these synthetic grafts.
引用
收藏
页码:582 / U2
页数:5
相关论文
共 5 条
[1]   The collagen-binding A-domains of integrins α1β1 and α2β1 recognize the same specific amino acid sequence, GFOGER, in native (triple-helical) collagens [J].
Knight, CG ;
Morton, LF ;
Peachey, AR ;
Tuckwell, DS ;
Farndale, RW ;
Barnes, MJ .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2000, 275 (01) :35-40
[2]   Plasma protein adsorption onto cell attachment controlled ion implanted collagen [J].
Kurotobi, K ;
Kaibara, M ;
Suzuki, Y ;
Iwaki, M ;
Nakajima, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2001, 175 :791-796
[3]   Ion implantation into collagen-coated surfaces for the development of small diameter artificial grafts [J].
Kurotobi, K ;
Kaibara, M ;
Suzuki, Y ;
Iwaki, M ;
Nakajima, H ;
Kaneko, S .
COLLOIDS AND SURFACES B-BIOINTERFACES, 2000, 19 (03) :227-235
[4]   THE INFLUENCE OF PREADSORBED CANINE VON WILLEBRAND FACTOR, FIBRONECTIN AND FIBRINOGEN ON EXVIVO ARTIFICIAL SURFACE-INDUCED THROMBOSIS [J].
LAMBRECHT, LK ;
YOUNG, BR ;
STAFFORD, RE ;
PARK, K ;
ALBRECHT, RM ;
MOSHER, DF ;
COOPER, SL .
THROMBOSIS RESEARCH, 1986, 41 (01) :99-117
[5]   Ion implantation into collagen for the substrate of small diameter artificial grafts [J].
Suzuki, Y ;
Iwata, H ;
Nakao, A ;
Iwaki, M ;
Kaibara, M ;
Sasabe, H ;
Kaneko, S ;
Nakajima, H ;
Kusakabe, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 127 :1019-1022