Stem cell derived in vivo-like human cardiac bodies in a microfluidic device for toxicity testing by beating frequency imaging

被引:38
作者
Bergstrom, Gunnar [1 ]
Christoffersson, Jonas [1 ]
Schwanke, Kristin [2 ]
Zweigerdt, Robert [2 ]
Mandenius, Carl-Fredrik [1 ]
机构
[1] Linkoping Univ, Dept Phys Chem & Biol IFM, Div Biotechnol, S-58183 Linkoping, Sweden
[2] Hannover Med Sch, Leibniz Res Labs Biotechnol & Artificial Organs L, D-30625 Hannover, Germany
基金
瑞典研究理事会;
关键词
CARDIOMYOCYTES; IDENTIFICATION; BIOMARKERS; MURINE; HEART; CHIP;
D O I
10.1039/c5lc00449g
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Beating in vivo-like human cardiac bodies (CBs) were used in a microfluidic device for testing cardiotoxicity. The CBs, cardiomyocyte cell clusters derived from induced pluripotent stem cells, exhibited typical structural and functional properties of the native human myocardium. The CBs were captured in niches along a perfusion channel in the device. Video imaging was utilized for automatic monitoring of the beating frequency of each individual CB. The device allowed assessment of cardiotoxic effects of drug substances doxorubicin, verapamil and quinidine on the 3D clustered cardiomyocytes. Beating frequency data recorded over a period of 6 hours are presented and compared to literature data. The results indicate that this microfluidic setup with imaging of CB characteristics provides a new opportunity for label-free, non-invasive investigation of toxic effects in a 3D microenvironment.
引用
收藏
页码:3242 / 3249
页数:8
相关论文
共 40 条
[1]   Microfluidic heart on a chip for higher throughput pharmacological studies [J].
Agarwal, Ashutosh ;
Goss, Josue Adrian ;
Cho, Alexander ;
McCain, Megan Laura ;
Parker, Kevin Kit .
LAB ON A CHIP, 2013, 13 (18) :3599-3608
[2]   Assaying cardiac biomarkers for toxicity testing using biosensing and cardiomyocytes derived from human embryonic stem cells [J].
Andersson, Henrik ;
Steel, Daniella ;
Asp, Julia ;
Dahlenborg, Kerstin ;
Jonsson, Marianne ;
Jeppsson, Anders ;
Lindahl, Anders ;
Kagedal, Bertil ;
Sartipy, Peter ;
Mandenius, Carl-Fredrik .
JOURNAL OF BIOTECHNOLOGY, 2010, 150 (01) :175-181
[3]   Monitoring of troponin release from cardiomyocytes during exposure to toxic substances using surface plasmon resonance biosensing [J].
Andersson, Henrik ;
Kagedal, Bertil ;
Mandenius, Carl-Fredrik .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 398 (03) :1395-1402
[4]   Highly Elastic Micropatterned Hydrogel for Engineering Functional Cardiac Tissue [J].
Annabi, Nasim ;
Tsang, Kelly ;
Mithieux, Suzanne M. ;
Nikkhah, Mehdi ;
Ameri, Afshin ;
Khademhosseini, Ali ;
Weiss, Anthony S. .
ADVANCED FUNCTIONAL MATERIALS, 2013, 23 (39) :4950-4959
[5]   Macroporous microcarriers for introducing cells into a microfluidic chip [J].
Bergstrom, G. ;
Nilsson, K. ;
Mandenius, C. -F. ;
Robinson, N. D. .
LAB ON A CHIP, 2014, 14 (18) :3502-3504
[6]  
Chouabe C, 1998, MOL PHARMACOL, V54, P695
[7]   The use of agarose microwells for scalable embryoid body formation and cardiac differentiation of human and murine pluripotent stem cells [J].
Dahlmann, Julia ;
Kensah, George ;
Kempf, Henning ;
Skvorc, David ;
Gawol, Anke ;
Elliott, David A. ;
Draeger, Gerald ;
Zweigerdt, Robert ;
Martin, Ulrich ;
Gruh, Ina .
BIOMATERIALS, 2013, 34 (10) :2463-2471
[8]   Comparison of Electrophysiological Data From Human-Induced Pluripotent Stem CellDerived Cardiomyocytes to Functional Preclinical Safety Assays [J].
Harris, Kate ;
Aylott, Mike ;
Cui, Yi ;
Louttit, James B. ;
McMahon, Nicholas C. ;
Sridhar, Arun .
TOXICOLOGICAL SCIENCES, 2013, 134 (02) :412-426
[9]  
Hayakawa T, 2012, TISSUE ENG PART C-ME, V18, P21, DOI [10.1089/ten.tec.2011.0273, 10.1089/ten.TEC.2011.0273]
[10]  
HILL RJ, 1989, MOL PHARMACOL, V36, P150