In this paper, the experimental studies were conducted on the gas/liquid two-phase flow by using a new double-cone flowmeter with diameter ratio of 0.8 in the 50mm-diameter horizontal pipe. The discharge coefficient of the double-cone flowmeter was calibrated by experimental methods in the water standard facility. The homogeneous model and the James model were applied to measure total flowrate of the gas/liquid two-phase flow, and the measurement errors were analyzed. A modified homogeneous model was proposed. The experimental results show that relative error of the modified model is within 6%, which indicates that the new model is effective to the total flowrate measurement. At the same time, it may prove that the double-cone flowmeter can be used in gas/liquid two-phase flow measurement.
引用
收藏
页码:1709 / 1712
页数:4
相关论文
共 11 条
[1]  
A Ifft S, 1993, P FLUIDS ENG C JUN 2, P37
[2]  
Dahlstrom Maron J., 1994, N SEA FLOW MEAS WORK
[3]  
Dong Feng, 2006, AIP C P, P208
[4]   2-PHASE FLOW MEASUREMENTS WITH SHARP-EDGED ORIFICES [J].
LIN, ZH .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 1982, 8 (06) :683-693
[5]  
Murdock J.W., 1962, J BASIC ENG AM SOC M, V84, P419, DOI DOI 10.1115/1.3658657
[6]  
R James, 1965, P I MEECH, V180, P594
[7]   Effect of upstream flow disturbances on the performance characteristics of a V-cone flowmeter [J].
Singh, S. N. ;
Seshadri, V. ;
Singh, R. K. ;
Gawhade, R. .
FLOW MEASUREMENT AND INSTRUMENTATION, 2006, 17 (05) :291-297
[8]   Horizontally installed cone differential pressure meter wet gas flow performance [J].
Steven, Richard .
FLOW MEASUREMENT AND INSTRUMENTATION, 2009, 20 (4-5) :152-167
[9]  
Tan Chao, 2009, SING INT INSTR MEAS, P62
[10]  
Zhang Fusheng, 2010, FLOW MEASUREMENT INS, V20, P1