Effect of Curing Light and Exposure Time on the Polymerization of Bulk-Fill Resin-Based Composites in Molar Teeth

被引:35
|
作者
Shimokawa, C. A. K. [1 ]
Turbino, M. L. [1 ]
Giannini, M. [2 ]
Braga, R. R. [3 ]
Price, R. B. [4 ]
机构
[1] Univ Sao Paulo, Sch Dent, Restorat Dent, Sao Paulo, Brazil
[2] Univ Estadual Campinas, Piracicaba Dent Sch, Restorat Dent, Piracicaba, Brazil
[3] Univ Sao Paulo, Sch Dent, Biomat & Oral Biol, Sao Paulo, Brazil
[4] Dalhousie Univ, Fac Dent, Dent Clin Sci, Halifax, NS, Canada
关键词
EMISSION-SPECTRUM; HIGH IRRADIANCE; BEAM PROFILE; DEPTH; CONVERSION; CURE; MICROHARDNESS; DENTISTRY; STRESS; OUTPUT;
D O I
10.2341/19-126-L
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: This study examined the influence of different light-curing units (LCUs) and exposure times on the microhardness across bulk-fill resin-based composite (RBC) restorations in a molar tooth. Methods and Materials: Tip diameter, radiant power, radiant exitance, emission spectra, and light beam profile were measured on two single-emission-peak LCUs (Celalux 3 and DeepCure-S) and two multiple-peak LCUs (Bluephase 20i and Valo Grand). A mold was made using a human molar that had a 12-mm mesial-distal length, a 2.5-mm deep occlusal box, and two 4.5-mm deep proximal boxes. Two bulk-fill RBCs (Filtek Bulk Fill Posterior and Tetric EvoCeram Bulk Fill) were photoactivated for 10 seconds and for 20 seconds, with the light guide positioned at the center of the occlusal surface. Microhardness was then measured across the transverse surface of the restorations. The light that reached the bottom of the proximal boxes was examined. Data were statistically analyzed with the Student t-test, two-way analysis of variance, and the Tukey post hoc test (alpha=0.05). Results: The four LCUs were different regarding all the tested characteristics. Even when using LCUs with wide tips and a homogeneous beam profile, there were significant differences in the microhardness results obtained at the central and proximal regions of the RBCs (p<0.05). LCUs with wider tips used for 20 seconds produced higher microhardness values (p<0.05). The multiple-peak LCUs produced greater hardness values in Tetric Evo-Ceram Bulk Fill than did the single-emission-peak LCUs (Celalux 3 and DeepCure-S). Results for the light measured at the bottom of proximal boxes showed that little light reached these regions when the light tip was positioned at the center of restorations. Conclusions: Curing lights with wide tips, homogeneous light beam profiles, and longer exposure times are preferred when light-curing large MOD restorations. Light curing from more than one position may be required for adequate photopolymerization.
引用
收藏
页码:E141 / E155
页数:15
相关论文
共 50 条
  • [1] Curing profile of bulk-fill resin-based composites
    Li, Xin
    Pongprueksa, Pong
    Van Meerbeek, Bart
    De Munck, Jan
    JOURNAL OF DENTISTRY, 2015, 43 (06) : 664 - 672
  • [2] Effect of light curing units on the polymerization of bulk fill resin-based composites
    Kenji Shimokawa, Carlos Alberto
    Turbino, Miriam Lacalle
    Giannini, Marcelo
    Braga, Roberto Ruggiero
    Price, Richard Bengt
    DENTAL MATERIALS, 2018, 34 (08) : 1211 - 1221
  • [3] Cuspal deflection and microleakage in pre molar teeth restored with bulk-fill resin-based composites
    Guler, Eda
    Karaman, Emel
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2014, 28 (20) : 2089 - 2099
  • [4] Bulk-fill resin composites: Polymerization properties and extended light curing
    Zorzin, Jose
    Maier, Eva
    Harre, Sarah
    Fey, Tobias
    Belli, Renan
    Lohbauer, Ulrich
    Petschelt, Anselm
    Taschner, Michael
    DENTAL MATERIALS, 2015, 31 (03) : 293 - 301
  • [5] Degree of Conversion and Polymerization Shrinkage of Bulk-Fill Resin-Based Composites
    Yu, P.
    Yap, A. U. J.
    Wang, X. Y.
    OPERATIVE DENTISTRY, 2017, 42 (01) : 82 - 89
  • [6] Impact of light-curing distance on the effectiveness of cure of bulk-fill resin-based composites
    Diab, Rana Abdelbaset
    Yap, Adrian Ujin
    Gonzalez, Maria Angela Garcia
    Yahya, Noor Azlin
    SAUDI DENTAL JOURNAL, 2021, 33 (08) : 1184 - 1189
  • [7] Polymerization shrinkage and shrinkage stress of bulk-fill and non-bulk-fill resin-based composites
    Yu, Peng
    Xu, Yong-Xiang
    Liu, Yu-Shu
    JOURNAL OF DENTAL SCIENCES, 2022, 17 (03) : 1212 - 1216
  • [8] Effect of Shortened Light-Curing Modes on Bulk-Fill Resin Composites
    Sampaio, C. S.
    Pizarro, P. G.
    Atria, P. J.
    Hirata, R.
    Giannini, M.
    Mahn, E.
    OPERATIVE DENTISTRY, 2020, 45 (05) : 496 - 505
  • [9] Effect of Light Curing Distance on Microhardness Profiles of Bulk-Fill Resin Composites
    Hasanain, Fatin A.
    Nassar, Hani M.
    Ajaj, Reem A.
    POLYMERS, 2022, 14 (03)
  • [10] Effect of Light-curing Unit Design and Mouth Opening on the Polymerization of Bulk-fill Resin-based Composite Restorations in Molars
    Moreira, Rodrigo Jose
    de Deus, Raissa Albuquerque
    Hordones Ribeiro, Maria Tereza
    Lourenco Braga, Stella Sueli
    Teodoro Schettini, Ana Cecilia
    Price, Richard Bengt
    Soares, Carlos Jose
    JOURNAL OF ADHESIVE DENTISTRY, 2021, 23 (02): : 121 - 131