CFD-based simulation to reduce greenhouse gas emissions from industrial plants

被引:39
作者
Sarjito [3 ]
Elveny, Marischa [1 ]
Jalil, Abduladheem Turki [4 ,5 ]
Davarpanah, Afshin [6 ]
Alfakeer, Majda [2 ]
Bahajjaj, Aboud Ahmed Awadh [7 ]
Ouladsmane, Mohamed [7 ]
机构
[1] Univ Sumatera Utara, Data Sci & Computat Intelligence Res Grp, Medan, Indonesia
[2] Princess Nourah bint Abdulrahman Univ, Coll Sci, Dept Chem, Riyadh 11671, Saudi Arabia
[3] Univ Muhammadiyah Surakarta, Dept Mech Engn, Surakarta 57102, Indonesia
[4] Yanka Kupala State Univ Grodno, Fac Biol & Ecol, Grodno, BELARUS
[5] Islamic Univ, Coll Med Technol, Najaf, Iraq
[6] Univ Medan Area, Data Sci & Computat Intelligence Res Grp, Medan, Indonesia
[7] King Saud Univ, Coll Sci, Chem Dept, Adv Mat Res Chair, Riyadh 11451, Saudi Arabia
关键词
ANSYS Fluent (R) software; dry low nitrogen oxide burner; Gibbs energy; greenhouse gas emission; steam component; NOX; PERFORMANCE; COMBUSTION; NETWORKS; NACLO; FLAME;
D O I
10.1515/ijcre-2021-0063
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Greenhouse gas (GHG) pollution is considered one of the challenging concerns in industrial plants, and to emit the appropriate designation in nitrogen oxide reduction, it is required to implement proper numerical simulation procedures. In this study, ANSYS Fluent (R) software is used as dynamic software to solve heat and mass flow transfer numerically by considering nonstructured networks for complex geometries. Dry nitrogen oxide burners have an additional thermocouple to provide an extra fuel pathway to combine with air. Then, standard K-epsilon is used in the numerical simulations to calculate thermal efficiency in combustion processes for turbulent flow regimes. It can cause the removal of 50% of nitrogen oxide into the atmosphere. Furthermore, by the increase of temperature, nitrogen oxide concentration has been increased in the system. After 1975 K, Fuel has been changed to dry fuel, and therefore nitrogen oxide concentration increased because the steam can provide a relatively non-combustible compound increase than fuel. On the other hand, regarding the water volume increase at inlet steam, nitrogen oxide volume percentage has been decreased dramatically, especially in the first periods of water volume increase. Consequently, when the steam percentage is increased instead of water, nitrogen oxide reduction is increased. Moreover, our simulation results have a proper match with Gibbs energy equilibrium.
引用
收藏
页码:1179 / 1186
页数:8
相关论文
共 91 条
[1]  
Abasi M., 2015, MAJLESI J ENERGY MAN, V4
[2]  
Abasi M., 2020, INT J IND ELECT CONT, V3, P447
[3]   Fault Location in Double-Circuit Transmission Lines Compensated by Generalized Unified Power Flow Controller (GUPFC) Based on Synchronous Current and Voltage Phasors [J].
Abasi, Mahyar ;
Saffarian, Alireza ;
Joorabian, Mahmood ;
Seifossadat, Seyyed Ghodratollah .
IEEE SYSTEMS JOURNAL, 2021, 15 (02) :2190-2200
[4]   Fault classification and fault area detection in GUPFC-compensated double-circuit transmission lines based on the analysis of active and reactive powers measured by PMUs [J].
Abasi, Mahyar ;
Saffarian, Alireza ;
Joorabian, Mahmood ;
Seifossadat, Seyyed Ghodratollah .
MEASUREMENT, 2021, 169
[5]  
Ahmed Usama Ali, 2020, CENTRAL ASIAN J ENV, V1, P130, DOI [10.22034/CAJESTI.2020.03.01, DOI 10.22034/CAJESTI.2020.03.01]
[6]  
Asgari R., 2021, CENT ASIAN J MED PHA, P22, DOI DOI 10.22034/CAJMPSI.2021.01.04
[7]  
Awan B., 2020, CENT ASIAN J ENV SCI, V1, P150, DOI DOI 10.22034/CAJESTI.2020.03.04
[8]   Design and tri-objective optimization of an energy plant integrated with near-zero energy building including energy storage: An application of dynamic simulation [J].
Bahramian, Fereydoun ;
Akbari, Amin ;
Nabavi, Miralireza ;
Esfandi, Saeed ;
Naeiji, Esfandiyar ;
Issakhov, Alibek .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 47
[9]  
Bayrakdar ME, 2020, COMPUT SYST SCI ENG, V35, P283
[10]   Two-Dimensional Interpolation Criterion Using DFT Coefficients [J].
Chen, Yuan ;
Duan, Liangtao ;
Sun, Weize ;
Xu, Jingxin .
CMC-COMPUTERS MATERIALS & CONTINUA, 2020, 62 (02) :849-859