Performance assessment of 20.4 kW eco-house grid-connected PV plant in Oman

被引:17
|
作者
Al-Badi, Abdullah [1 ]
机构
[1] Sultan Qaboos Univ, Coll Engn, Dept Elect & Comp Engn, Muscat, Oman
关键词
Grid connected PV; dust; Oman climate; eco-house; PHOTOVOLTAIC POWER-PLANT; OUTDOOR PERFORMANCE; SYSTEM; SOLAR; EFFICIENCY; DUST; INSTALLATION; ENERGY; ISLAND;
D O I
10.1080/19397038.2019.1658824
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this article is to analyse the performance of the Photovoltaic (PV) and to study the effect of soiling on the energy generation under Muscat environmental conditions. The generated energy is consumed in the eco-house, and the access energy is fed back to the electric grid. Two-ways metre was used to record the energy taken from the grid or fed back to the grid. The system was monitored from December 2014 until today. Various performance parameters of the plant were evaluated which include system efficiency, performance ratio (PR), capacity factor (CF) and different types of PV system losses and yields. The annual average values of recorded ambient temperature and solar radiation were 32 degrees C and 482 W/m(2), respectively. The total annual energy produced was 23,595 kWh, whereas the annual average daily reference yield, array yield and final yield were 5.59, 3.78 and 3.64 kWh/kW(P)/day, respectively. The annual average daily PR and CF were 0.67 and 0.15, respectively, while the annual average system efficiency was 10.3%. Furthermore, the annual average daily capture, system and cell temperature losses were 1.82, 0.14 and 2.95 h/day,respectively, with a small reduction in energy production when modules left uncleaned.
引用
收藏
页码:230 / 241
页数:12
相关论文
共 50 条
  • [21] A target-oriented performance assessment and model development of a grid-connected solar PV (GCPV) system for a commercial building in Malaysia
    Saleheen, Mohammed Zeehan
    Salema, Arshad Adam
    Islam, Shah Mohammad Mominul
    Sarimuthu, Charles R.
    Hasan, Md Zobaer
    RENEWABLE ENERGY, 2021, 171 : 371 - 382
  • [22] Visualization of Operational Performance of Grid-Connected PV Systems in selected European Countries
    Moraitis, Panagiotis
    Kausika, Bhavya B.
    van Sark, Wilfried G. J. H. M.
    2015 IEEE 42ND PHOTOVOLTAIC SPECIALIST CONFERENCE (PVSC), 2015,
  • [23] Monitoring, measured and simulated performance analysis of a 2.4 kWp grid-connected PV system installed on the Mulhouse campus, France
    Haffaf, Aziz
    Lakdja, Fatiha
    Abdeslam, Djaffar Ould
    Meziane, Rachid
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2021, 62 : 44 - 55
  • [24] Analysis of measured and simulated performance of a grid-connected PV system in eastern India
    Sonali Goel
    Renu Sharma
    Environment, Development and Sustainability, 2021, 23 : 451 - 476
  • [25] Performance Comparison of Single-Phase Transformerless Grid-Connected PV Inverters
    Farhadi-Kangarlu, Mohammad
    Mohammadi, Farid
    9TH ANNUAL POWER ELECTRONICS, DRIVES SYSTEMS, AND TECHNOLOGIES CONFERENCE (PEDSTC2018), 2018, : 71 - 76
  • [26] Hybrid SCA and adaptive controller to enhance the performance of grid-connected PV system
    Mokhtar, Mohamed
    Marei, Mostafa, I
    Attia, Mahmoud A.
    AIN SHAMS ENGINEERING JOURNAL, 2021, 12 (04) : 3775 - 3781
  • [27] Overview of the state of technique for PV inverters used in low voltage grid-connected PV systems: Inverters below 10 kW
    Salas, V.
    Olias, E.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2009, 13 (6-7) : 1541 - 1550
  • [28] Overview of the state of technique for PV inverters used in low voltage grid-connected PV systems: Inverters above 10 kW
    Salas, V.
    Olias, E.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2011, 15 (02) : 1250 - 1257
  • [29] Analytical assessment of Ain Skhouna PV plant performance connected to the grid under a semi-arid climate in Algeria
    Ihaddadene, Razika
    Jed, Mohamed El Hassen
    Ihaddadene, Nabila
    De Souza, Amaury
    SOLAR ENERGY, 2022, 232 : 52 - 62
  • [30] Performance analysis and modelling of a 50 MW grid-connected photovoltaic plant in Spain after 12 years of operation
    Fuster-Palop, Enrique
    Vargas-Salgado, Carlos
    Carlos Ferri-Revert, Juan
    Paya, Jorge
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2022, 170