No clinical difference between fixed- and mobile-bearing cruciate-retaining total knee arthroplasty: a prospective randomized study

被引:26
作者
Bailey, O. [1 ]
Ferguson, K. [2 ]
Crawfurd, E. [3 ]
James, P. [4 ]
May, P. A. [1 ]
Brown, S. [3 ]
Blyth, M. [2 ]
Leach, W. J. [1 ]
机构
[1] Univ Glasgow, Western Infirm, Glasgow G11 6NT, Lanark, Scotland
[2] Royal Infirm, Glasgow G31 2ER, Lanark, Scotland
[3] Northampton Gen Hosp, Northampton, England
[4] City Hosp Nottingham, Nottingham, England
关键词
Knee; Arthroplasty; Mobile-bearing; Rotating-platform; Fixed-bearing; ROTATING-PLATFORM; IN-VITRO; GAIT ANALYSIS; FOLLOW-UP; KINEMATICS; DESIGN; REPLACEMENTS; OSTEOLYSIS; PROSTHESES; FLEXION;
D O I
10.1007/s00167-014-2877-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
It is hypothesized that mobile polyethylene bearings in total knee arthroplasty (TKA) may confer benefits with regard to range of motion and have improved clinical outcome scores in comparison with an arthroplasty with a fixed-bearing design. Our study compares clinical outcomes between patients who undergo TKA with either a rotating platform or fixed bearing using a posterior cruciate-retaining design. Three hundred and thirty-one patients were randomized to receive either a rotating-platform (161 patients) or a fixed-bearing (170 patients) implant. All patients were assessed pre-operatively and at 1 and 2 years post-operatively using standard tools (range of movement, Oxford Knee Score, American Knee Society Score, SF12 and Patella Score). There was no difference in pre- to 2-year post-operative outcomes between the groups with regard to improvement in range of motion (10A degrees A A +/- A 16 vs. 9A degrees A A +/- A 15), improvement in Oxford Knee Score (-17.6 +/- A 9.9 vs. -19.1 +/- A 8.4), improvement in American Knee Society Score (49.5 +/- A 24.7 vs. 50.7 +/- A 21.0), function (23.6 +/- A 19.6 vs. 25.0 +/- A 22.5) and pain (34.9 +/- A 16.2 vs. 35.8 +/- A 14.1) subscores, improvement in SF12 Score (10.0 +/- A 16.3 vs. 12.3 +/- A 15.8) or improvement in Patella Score (9.7 +/- A 7.4 vs. 10.6 +/- A 7.1). No difference was demonstrated in clinical outcome between patients with a rotating-platform and fixed-bearing posterior cruciate-retaining TKA at 2-year follow-up. I.
引用
收藏
页码:1653 / 1659
页数:7
相关论文
共 37 条
[1]   Comparison of mobile-bearing and fixed-bearing total knee arthroplasty - A prospective randomized study [J].
Aglietti, P ;
Baldini, A ;
Buzzi, R ;
Lup, D ;
De Luca, L .
JOURNAL OF ARTHROPLASTY, 2005, 20 (02) :145-153
[2]   Knee motions during maximum flexion in fixed and mobile-bearing arthroplasties [J].
Banks, S ;
Bellemans, J ;
Nozaki, H ;
Whiteside, LA ;
Harman, M ;
Hodge, WA .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (410) :131-138
[3]   Improving the quality of reporting of randomized controlled trials - The CONSORT statement [J].
Begg, C ;
Cho, M ;
Eastwood, S ;
Horton, R ;
Moher, D ;
Olkin, I ;
Pitkin, R ;
Rennie, D ;
Schulz, KF ;
Simel, D ;
Stroup, DF .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (08) :637-639
[4]   A comparison of fixed-bearing and mobile-bearing total knee arthroplasty at a minimum follow-up of 4.5 years [J].
Bhan, S ;
Malhotra, R ;
Kiran, EK ;
Shukla, S ;
Bijjawara, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2005, 87A (10) :2290-2296
[5]   Primary total knee arthroplasty using the PFC Sigma®-rotating platform cruciate retaining endoprosthesis - A 6 year follow up [J].
Bhatt, H. ;
Rambani, R. ;
White, W. ;
Chakrabarty, G. .
KNEE, 2012, 19 (06) :856-859
[6]   In Vitro Comparison of Fixed- and Mobile Meniscal-Bearing Unicondylar Knee Arthroplasties [J].
Burton, Andrew ;
Williams, Sophie ;
Brockett, Claire L. ;
Fisher, John .
JOURNAL OF ARTHROPLASTY, 2012, 27 (08) :1452-1459
[7]   Kinematics of a cementless mobile bearing posterior cruciate ligament-retaining total knee arthroplasty [J].
Chouteau, J. ;
Lerat, J. ;
Testa, R. ;
moyen, B. ;
Fessy, M. H. ;
Banks, S. A. .
KNEE, 2009, 16 (03) :223-227
[8]  
D'Lima DD, 2001, CLIN ORTHOP RELAT R, P235
[9]   Posterior Cruciate-retaining, Rotating-platform Total Knee Arthroplasty: Minimum 4-year Follow-up Study [J].
Elwood, Justin J. ;
Callaghan, John J. ;
Liu, Steve S. ;
Goetz, Devon D. .
ORTHOPEDICS, 2012, 35 (12) :E1699-E1704
[10]  
EWALD FC, 1989, CLIN ORTHOP RELAT R, P9