Use of an empty, plasmapore-covered titanium cage for interbody fusion after anterior cervical microdiscectomy

被引:11
作者
Krayenbuehl, Niklaus [1 ]
Schneider, Christian [1 ]
Landolt, Hans [1 ]
Fandino, Javier [1 ]
机构
[1] Kantonsspital Aarau, Dept Neurosurg, Aarau, Switzerland
关键词
cervical disc disease; anterior cervical discectomy; cage; fusion;
D O I
10.1016/j.jocn.2006.12.011
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The use of cages of different material and shapes for cervical discectomy with fusion (ACDF) has increased during the last few years. The use of additional osteogenic material is controversial. We prospectively evaluated an empty, Plasmapore (R)-covered titanium cage (PCTC) in 45 patients undergoing 58 ACDFs. Patients were evaluated using standard clinical and radiological criteria. Good to excellent outcome was achieved in 93%, 78% and 75% after 3, 12 and 48 months, respectively. Sixty-five percent of patients could resume their prior work after 48 months. Disc space height and lordosis could be preserved in all cases. Two percent of the treated levels showed subsidence and 2% increased segmental motion. There were no procedure-related complications. Implantation of an empty PCTC after microsurgical anterior cervical discectomy is a safe procedure with good results and low incidence of complications. Disc height and lordosis can be preserved with low incidence of subsidence and good fusion rates. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:11 / 17
页数:7
相关论文
共 48 条
[1]   Anterior cervical fusion with carbon fiber cage containing coralline hydroxyapatite: preliminary observations in 45 consecutive cases of soft-disc herniation [J].
Agrillo, U ;
Mastronardi, L ;
Puzzilli, F .
JOURNAL OF NEUROSURGERY, 2002, 96 (03) :273-276
[2]  
BARLOCHER C, 2002, NEUROSURG FOCUS, V12
[3]   Subsidence of stand-alone cervical carbon fiber cages [J].
Bartels, RHMA ;
Donk, RD ;
Feuth, T .
NEUROSURGERY, 2006, 58 (03) :502-507
[4]   Height of cervical foramina after anterior discectomy and implantation of a carbon fiber cage [J].
Bartels, RHMA ;
Donk, R ;
Azn, RV .
JOURNAL OF NEUROSURGERY, 2001, 95 (01) :40-42
[5]  
BOBYN JD, 1980, CLIN ORTHOP RELAT R, P263
[6]  
Burkus JK, 2006, J NEUROSURG, V104, pA635
[7]  
Cho DY, 2003, NEUROSURGERY, V52, P693
[8]   Preliminary experience using a polyetheretherketone (PEEK) cage in the treatment of cervical disc disease [J].
Cho, DY ;
Liau, WR ;
Lee, WY ;
Liu, JT ;
Chiu, CL ;
Sheu, PC .
NEUROSURGERY, 2002, 51 (06) :1343-1349
[9]   Cervical foraminal area and intervertebral height changes after titanium ring cage placement: Preliminary results [J].
Colpan, ME ;
Attar, A ;
Sekerci, Z ;
Tuna, H ;
Egemen, N .
JOURNAL OF CLINICAL NEUROSCIENCE, 2006, 13 (02) :228-232
[10]   Prospective randomized controlled study of the Bryan Cervical Disc: early clinical results from a single investigational site - Invited submission from the Joint Section Meeting on Disorders of the Spine and Peripheral Nerves, March 2005 [J].
Coric, D ;
Finger, F ;
Boltes, P .
JOURNAL OF NEUROSURGERY-SPINE, 2006, 4 (01) :31-35