Validation of High-Resolution peripheral Quantitative Computed Tomography-Derived Achilles Tendon Properties Against Diagnostic Ultrasound

被引:0
|
作者
Fung, Hugo J. W. [1 ,2 ]
Cheung, Angela M. [2 ,3 ,4 ,5 ]
Mathur, Sunita [6 ,7 ]
Szabo, Eva [2 ,5 ]
Wong, Andy K. O. [2 ,4 ,5 ,7 ,8 ]
机构
[1] Univ Toronto, Fac Kinesiol & Phys Educ, Dept Exercise Sci, Toronto, ON, Canada
[2] Univ Toronto, Ctr Excellence Skeletal Hlth Assessment, Toronto, ON, Canada
[3] Univ Hlth Network, Dept Med, Toronto, ON, Canada
[4] Univ Hlth Network, Toronto Gen Hosp Res Inst, Toronto, ON, Canada
[5] Univ Hlth Network, Schroeders Arthrit Inst, Osteoporosis Program, Toronto, ON, Canada
[6] Univ Toronto, Fac Med, Dept Phys Therapy, Toronto, ON, Canada
[7] Univ Toronto, Fac Med, Rehabil Sci Inst, Toronto, ON, Canada
[8] Univ Toronto, Dalla Lana Sch Publ Hlth, Dept Epidemiol, Toronto, ON, Canada
关键词
Achilles Tendon; HR-pQCT; Tendon Cross-Sectional Area; Tendon Density; Ultrasound; IN-VIVO ASSESSMENT; BONE MICROARCHITECTURE; DISTAL RADIUS; STRENGTH; MUSCLE; REPRODUCIBILITY; TENDINOPATHY; EXPRESSION; PRECISION; EXERCISE;
D O I
暂无
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Objectives: 1) To assess the precision of high resolution peripheral quantitative computed tomography (HR-pQCT)derived Achilles tendon (AT) cross-sectional area (HR AT-CSA) and density, and 2) to validate HR AT-CSA against ultrasound-derived AT-CSA (US AT-CSA). Methods: Women and men (>= 50 years) had HR-pQCT (0.082mm isotropic) and US scans (B-mode) performed on the non-dominant ankle. Linear regression and Bland-Altman analyses assessed systematic differences between HR-pQCT and US-derived AT-CSA. Precision measured by % root mean square coefficients of variation (%RMSCV) and agreement by type 2,1 intraclass correlation coefficients (ICC2,1), were determined for testretest US AT-CSA scans, and analysis-reanalysis of 30 HR-pQCT and US images. Results: Among 44 participants, HR and US AT-CSA were strongly correlated (R2=0.84, p<0.01, B=1.05[0.90-1.19]), with no differences between modalities (p=0.37). Bland-Altman analysis revealed minimal systematic bias (-0.7mm2[-10.7-9.3]; 1.3%) between HR-pQCT and US-derived AT-CSA with smaller AT-CSA values showing larger inter-modality differences (R2=0.098, B=-0.137 [-0.268--0.008], p=0.039). US AT-CSA demonstrated excellent test-retest precision (ICC2,1=0.998, %RMSCV=1.04%). Analysis-reanalysis of HR-pQCT AT-density and both HR-pQCT and US AT-CSA displayed ICC2,1 above 0.95 and %RMSCV within 3%. Conclusion: HR-pQCT can examine AT-morphometry with acceptable analytical precision. Future studies should explore these metrics' association with functional outcomes and ankle-bone structural and mechanical properties.
引用
收藏
页码:203 / 211
页数:9
相关论文
共 50 条
  • [21] Accuracy of volumetric bone mineral density measurement in high-resolution peripheral quantitative computed tomography
    Sekhon, Kiranjit
    Kazakia, Galateia J.
    Burghardt, Andrew J.
    Hermannsson, Bryan
    Majumdar, Sharmila
    BONE, 2009, 45 (03) : 473 - 479
  • [22] A Case Report of Abnormal Fracture Healing as Detected With High-Resolution Peripheral Quantitative Computed Tomography
    Heyer, Frans L.
    de Jong, Joost J. A.
    Smeets, Rob J. E. M.
    Arts, Jacobus J.
    Poeze, Martijn
    Geusens's, Piet E.
    van Rietbergen, Bert
    van den Bergh, Joop P.
    Willems, Paul C.
    JOURNAL OF CLINICAL DENSITOMETRY, 2017, 20 (04) : 486 - 489
  • [23] A Critical Comparison Between Two Scanning Protocols of High-Resolution Peripheral Quantitative Computed Tomography at the Distal Radius in Adolescents
    Cheuk, Ka-Yee
    Tam, Elisa Man-Shan
    Yu, Fiona Wai-Ping
    Yip, Benjamin Hon-Kei
    Hung, Vivian Wing-Yin
    Wang, Xiaofang
    Ghasem-Zadeh, Ali
    Zhu, Tracy Y.
    Qin, Ling
    Cheng, Jack Chun-Yiu
    Lam, Tsz-Ping
    JOURNAL OF CLINICAL DENSITOMETRY, 2016, 19 (03) : 305 - 315
  • [24] Bone microstructure of adult patients with non-surgical hypoparathyroidism assessed by high-resolution peripheral quantitative computed tomography
    Liu, J.
    Chen, S.
    Quan, T.
    Wang, Y.
    Wang, O.
    Nie, M.
    Jiang, Y.
    Li, M.
    Xing, X.
    Xia, W.
    OSTEOPOROSIS INTERNATIONAL, 2020, 31 (11) : 2219 - 2230
  • [25] Clinical cone beam computed tomography compared to high-resolution peripheral computed tomography in the assessment of distal radius bone
    de Charry, C.
    Boutroy, S.
    Ellouz, R.
    Duboeuf, F.
    Chapurlat, R.
    Follet, H.
    Pialat, J. B.
    OSTEOPOROSIS INTERNATIONAL, 2016, 27 (10) : 3073 - 3082
  • [26] IN VIVO MEASUREMENTS OF CORTICAL THICKNESS AND POROSITY AT THE PROXIMAL THIRD OF THE TIBIA USING GUIDED WAVES: COMPARISON WITH SITE-MATCHED PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY AND DISTAL HIGH-RESOLUTION PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY
    Schneider, Johannes
    Ramiandrisoa, Donatien
    Armbrecht, Gabriele
    Ritter, Zully
    Felsenberg, Dieter
    Raum, Kay
    Minonzio, Jean-Gabriel
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (05) : 1234 - 1242
  • [27] Influence of soft tissue on bone density and microarchitecture measurements by high-resolution peripheral quantitative computed tomography
    Caksa, Signe
    Yuan, Amy
    Rudolph, Sara E.
    Yu, Elaine W.
    Popp, Kristin L.
    Bouxsein, Mary L.
    BONE, 2019, 124 : 47 - 52
  • [28] Improved reproducibility of high-resolution peripheral quantitative computed tomography for measurement of bone quality
    MacNeil, Joshua A.
    Boyd, Steven K.
    MEDICAL ENGINEERING & PHYSICS, 2008, 30 (06) : 792 - 799
  • [29] Consequences of Hyperthyroidism and Its Treatment for Bone Microarchitecture Assessed by High-Resolution Peripheral Quantitative Computed Tomography
    Nicolaisen, Pia
    Obling, Maria Lohman
    Winther, Kristian Hillert
    Hansen, Stinus
    Hermann, Anne Pernille
    Hegedus, Laszlo
    Bonnema, Steen Joop
    Brix, Thomas Heiberg
    THYROID, 2021, 31 (02) : 208 - 216
  • [30] Bone Evaluation by High-Resolution Peripheral Quantitative Computed Tomography in Patients With Adrenal Incidentaloma
    Moraes, Aline Barbosa
    de Paula, Marcela Pessoa
    Paranhos-Neto, Francisco de Paula
    Ribeiro Cavalari, Emanuela Mello
    Cordeiro de Morais, Felipe Fernandes
    Carvalho Curi, Daniel Silva
    Cardoso Lima, Luis Felipe
    Carvalho de Mendonca, Laura Maria
    Fleiuss Farias, Maria Lucia
    Madeira, Miguel
    Vieira Neto, Leonardo
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2020, 105 (08) : E2726 - E2737