Corrosion of steel fibre reinforced concrete from the cracks

被引:179
|
作者
Granju, JL [1 ]
Balouch, SU [1 ]
机构
[1] UPS, INSA, Lab Mat & Durabilite Construct, F-31077 Toulouse, France
关键词
E. fibre reinforcement; corrosion; steel fibres;
D O I
10.1016/j.cemconres.2004.06.032
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The corrosion of steel fibres in the cracked section has been under investigation by many researchers since the last 15 years. It is reported widely that in case of steel fibres reinforced concrete (SFRC), corrosion is less active as compared with steel bars. In the cracked section, the durability of the material depends on the performance of the bridging capacity of the fibres embedded in the concrete. The corrosion of the fibres not only could produce the spalling of concrete but it could also reduce the sectional area of the fibres, turning the durability of structures in danger. This study focuses on those two aspects of fibre corrosion. The tests were performed on cracked SFRC samples with 0.5 mm crack mouth openings (CMOs) exposed to marine-like environment for 1 year. The results confirm the small sensitivity of SFRC to corrosion. Surprisingly, they made appear an increase of the flexural strength after corrosion. The factors affecting the corrosion of the fibres and the reasons for the increase in flexural strength after corrosion are discussed. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:572 / 577
页数:6
相关论文
共 50 条
  • [1] Surface corrosion of steel fibre reinforced concrete
    Balouch, S. U.
    Forth, J. P.
    Granju, J. -L.
    CEMENT AND CONCRETE RESEARCH, 2010, 40 (03) : 410 - 414
  • [2] Shear transfer across cracks in steel fibre reinforced concrete
    Kaufmann, Walter
    Amin, Ali
    Beck, Alexander
    Lee, Minu
    ENGINEERING STRUCTURES, 2019, 186 : 508 - 524
  • [3] Corrosion resistance of steel fibre reinforced concrete - A literature review
    Marcos-Meson, Victor
    Michel, Alexander
    Solgaard, Anders
    Fischer, Gregor
    Edvardsen, Carola
    Skovhus, Torben Lund
    CEMENT AND CONCRETE RESEARCH, 2018, 103 : 1 - 20
  • [4] Stray current induced corrosion of steel fibre reinforced concrete
    Tang, Kangkang
    CEMENT AND CONCRETE RESEARCH, 2017, 100 : 445 - 456
  • [5] Correlation between concrete cracks and corrosion characteristics of steel reinforcement in pre-cracked plain and fibre-reinforced concrete beams
    Chen, E.
    Berrocal, Carlos G.
    Lofgren, Ingemar
    Lundgren, Karin
    MATERIALS AND STRUCTURES, 2020, 53 (02)
  • [6] Correlation between concrete cracks and corrosion characteristics of steel reinforcement in pre-cracked plain and fibre-reinforced concrete beams
    E. Chen
    Carlos G. Berrocal
    Ingemar Löfgren
    Karin Lundgren
    Materials and Structures, 2020, 53
  • [7] A computational model for simulation of steel fibre reinforced concrete with explicit fibres and cracks
    Carvalho, Marcelo R.
    Barros, Joaquim A. O.
    Zhang, Yuye
    Dias-da-Costa, Daniel
    COMPUTER METHODS IN APPLIED MECHANICS AND ENGINEERING, 2020, 363
  • [8] CORROSION OF STEEL IN REINFORCED CONCRETE
    GIULIANI, L
    METALLURGIA ITALIANA, 1970, 62 (10): : 394 - &
  • [9] Corrosion Effects on the Strength Properties of Steel Fibre Reinforced Concrete Containing Slag and Corrosion Inhibitor
    Anandan, Sivakumar
    Manoharan, Sounthararajan Vallarasu
    Sengottian, Thirumurugan
    INTERNATIONAL JOURNAL OF CORROSION, 2014, 2014 (2014)
  • [10] Corrosion resistance of electrified railway tunnels made of steel fibre reinforced concrete
    Tang, Kangkang
    Wilkinson, Stephen
    CONSTRUCTION AND BUILDING MATERIALS, 2020, 230