An investigation of the role of defect levels on the radiation response of synthetic diamond crystals when used as sensors for the detection of mammography X-rays

被引:6
作者
Ade, Nicholas [1 ]
机构
[1] Univ Free State, Med Phys Dept, ZA-9300 Bloemfontein, South Africa
基金
新加坡国家研究基金会;
关键词
Diamond sensors; Mammography X-rays; Pre-irradiation; Sensitivity; Defects; CHEMICAL-VAPOR-DEPOSITION; HIGH-ENERGY ELECTRON; DOSE-RATE DEPENDENCE; CVD-DIAMOND; RAMAN-SPECTROSCOPY; DOSIMETRIC APPLICATIONS; PHOTON BEAMS; RADIOTHERAPY; PROBE; FILMS;
D O I
10.1016/j.apradiso.2017.06.021
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
This study evaluates the role of defects on the performances of synthetic diamond sensors on exposure to mammography X-rays. Through systematic investigations, the main cause of instability of response of examined sensors necessitating pre-irradiation was isolated and ascribed to the presence of ambient light which has the effect of emptying shallow trapping levels. The changes in response between measurements in light and dark conditions varied from 2.8 +/- 1.2% to 63.0 +/- 0.3%. Sensitivities between 0.4 and 6.7 nC Gy(-1) mm(-3) determined for the sensors varied with defect levels. The study indicates that differences in crystal quality due to the presence and influence of defects would cause a discrepancy in the dosimetric performances of various diamond detectors. Once a sensor plate is selected (based on the influence of defect levels) and coupled to the probe housing with the response of the diamond sensor stabilised and appropriately shielded from ambient light, daily priming is not needed.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 42 条
[21]   Requirements for synthetic diamond devices for radiotherapy dosimetry applications [J].
Guerrero, MJ ;
Tromson, D ;
Rebisz, M ;
Mer, C ;
Bazin, B ;
Bergonzo, P .
DIAMOND AND RELATED MATERIALS, 2004, 13 (11-12) :2046-2051
[22]   Investigation of photon beam output factors for conformal radiation therapy -: Monte Carlo simulations and measurements [J].
Haryanto, F ;
Fippel, M ;
Laub, W ;
Dohm, O ;
Nüsslin, F .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (11) :N133-N143
[23]   EVALUATION OF A PTW DIAMOND DETECTOR FOR ELECTRON-BEAM MEASUREMENTS [J].
HEYDARIAN, M ;
HOBAN, PW ;
BECKHAM, WA ;
BORCHARDT, IM ;
BEDDOE, AH .
PHYSICS IN MEDICINE AND BIOLOGY, 1993, 38 (08) :1035-1042
[24]   DOSE-RATE DEPENDENCE OF A PTW DIAMOND DETECTOR IN THE DOSIMETRY OF A 6 MV PHOTON-BEAM [J].
HOBAN, PW ;
HEYDARIAN, M ;
BECKHAM, WA ;
BEDDOE, AH .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (08) :1219-1229
[25]   DIAMOND RADIATION DETECTORS [J].
KANIA, DR ;
LANDSTRASS, MI ;
PLANO, MA ;
PAN, LS ;
HAN, S .
DIAMOND AND RELATED MATERIALS, 1993, 2 (5-7) :1012-1019
[26]   SYNTHETIC DIAMONDS AS IONIZATION-CHAMBER RADIATION DETECTORS IN BIOLOGICAL ENVIRONMENTS [J].
KEDDY, RJ ;
NAM, TL ;
BURNS, RC .
PHYSICS IN MEDICINE AND BIOLOGY, 1987, 32 (06) :751-759
[27]   A diamond detector in the dosimetry of high-energy electron and photon beams [J].
Laub, WU ;
Kaulich, TW ;
Nüsslin, F .
PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (09) :2183-2192
[28]   Analysis of Output Factors with Various Detectors in Small-field Electron-beam Radiotherapy [J].
Lee, Sang Hoon ;
Kim, Juree ;
Nam, Yoon Seok ;
Cho, Samju ;
Kwon, Sooil ;
Lee, Suk ;
Shim, Jang Bo ;
Kim, Chul Yong ;
Min, Chul Kee ;
Cho, Kwang Hwan ;
Huh, HyunDo .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (05) :875-880
[29]   CVD diamond detectors for nuclear and dosimetric applications [J].
Manfredotti, C .
DIAMOND AND RELATED MATERIALS, 2005, 14 (3-7) :531-540
[30]   CVD diamond microdosimeters [J].
Manfredotti, C ;
Lo Giudice, A ;
Ricciardi, C ;
Paolini, C ;
Massa, E ;
Fizzotti, F ;
Vittone, E .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 458 (1-2) :360-364