In vitro biomechanical comparison of pedicle screws, sublaminar hooks, and sublaminar cables

被引:46
作者
Hitchon, PW
Brenton, MD
Black, AG
From, A
Harrod, JS
Barry, C
Serhan, H
Torner, JC
机构
[1] Univ Iowa, Roy J & Lucille A Carver Coll Med, Coll Publ Hlth, Dept Neurosurg, Iowa City, IA USA
[2] Univ Iowa, Roy J & Lucille A Carver Coll Med, Coll Publ Hlth, Dept Biomed Engn, Iowa City, IA USA
[3] Univ Iowa, Roy J & Lucille A Carver Coll Med, Coll Publ Hlth, Dept Epidemiol, Iowa City, IA USA
[4] Vet Adm Med Ctr, Iowa City, IA USA
关键词
pedicle screw; sublaminar hook; sublaminar cable; bone mineral density; biomechanical study;
D O I
10.3171/spi.2003.99.1.0104
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Object. Three types of posterior thoracolumbar implants are in use today: pedicle screws, sublaminar titanium cables, and sublaminar hooks. The authors conducted a biomechanical comparison of these three implants in human cadaveric spines. Methods. Spine specimens (T5-12) were harvested, radiographically assessed for fractures or metastases, and their bone mineral density (BMD) was measured. Individual vertebrae were disarticulated and fitted with either pedicle screws, sublaminar cables, or bilateral claw hooks. The longitudinal component of each construct consisted of bilateral 10-cm rods connected with two cross-connectors. The vertebral body was embedded in cement, and the rods were affixed to a ball-and-socket apparatus for the application of a distraction force. The authors analyzed 1) 20 vertebrae implanted with screws; 2) 20 with hooks, and 3) 20 with cables. The maximum pullout (MPO) forces prior to failure (mean +/- standard deviation) for the screw, hook, and cable implants were 972 +/- 330, 802 +/- 356, and 654 +/- 248 N, respectively (p = 0.0375). Cables allowed significantly greater displacement (6.80 +/- 3.95 mm) prior to reaching the MPO force than hooks (3.73 +/- 1.42 mm) and screws (4.42 +/- 2.15 mm [p = 0.0108]). Eleven screw-implanted vertebrae failed because of screw pullout. All hook-and-cable-implanted vertebrae failed because of pedicle, middle column, or laminar fracture. Conclusions. These findings suggest that screws possess the greatest pullout strength of the three fixation systems. Sublaminar cables are the least rigid of the three. When screw failure occurred, the mechanism was generally screw backout, without vertebral fractures.
引用
收藏
页码:104 / 109
页数:6
相关论文
共 30 条
  • [11] Ebelke DK, 1991, SPINE, V16, P428
  • [12] FLORES E, 1995, TECHNIQUES SPINAL FU
  • [13] RELATION OF VERTEBRAL BONE SCREW AXIAL PULLOUT STRENGTH TO QUANTITATIVE COMPUTED TOMOGRAPHIC TRABECULAR BONE-MINERAL CONTENT
    GILBERT, SG
    JOHNS, PC
    CHOW, DC
    BLACK, RC
    [J]. JOURNAL OF SPINAL DISORDERS, 1993, 6 (06): : 513 - 521
  • [14] Hadjipavlou AG, 1997, J SPINAL DISORD, V10, P12
  • [15] Hitchon Patrick W., 1995, P204
  • [16] Hitchon Patrick W., 1995, P198
  • [17] Factors affecting the pullout strength of self-drilling and self-tapping anterior cervical screws
    Hitchon, PW
    Brenton, MD
    Coppes, JK
    From, AM
    Torner, JC
    [J]. SPINE, 2003, 28 (01) : 9 - 13
  • [18] Biomechanical evaluation of occipitocervical instrumentation: screw compared with wire fixation
    Hurlbert, RJ
    Crawford, NR
    Choi, WG
    Dickman, CA
    [J]. JOURNAL OF NEUROSURGERY, 1999, 90 (01) : 84 - 90
  • [19] Krag M H, 1988, J Spinal Disord, V1, P287
  • [20] Biomechanical evaluation of diagonal fixation in pedicle screw instrumentation
    Lim, TH
    Kim, JG
    Fujiwara, A
    Yoon, TT
    Lee, SC
    Ha, JW
    An, HS
    [J]. SPINE, 2001, 26 (22) : 2498 - 2503