A digital pulse processing system dedicated to CdZnTe detectors

被引:8
|
作者
Montémont, G [1 ]
Moulin, C [1 ]
Isard, K [1 ]
Verger, L [1 ]
机构
[1] CEA, LETI, F-38054 Grenoble, France
关键词
bi-parametric spectrum; CdZnTe; digital signal processing; gamma-ray detectors; pulse processing;
D O I
10.1109/TNS.2005.856860
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Pulse processing methods are very useful to improve CdZnTe detector performances. They allow a fine-tuned compensation of charge loss and provide knowledge on interaction location. We present a theoretical framework for the optimization of bi-parametric systems. A refined digital-based bi-parametric system allowing identification of multiple interaction events is presented and results are discussed.
引用
收藏
页码:2017 / 2022
页数:6
相关论文
共 50 条
  • [1] A digital pulse processing system dedicated to CdZnTe detectors
    Montémont, G
    Moulin, C
    Isard, K
    Verger, L
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4307 - 4311
  • [2] Digital pulse processing for planar TlBr detectors
    Nakhostin, M.
    Hitomi, K.
    Ishii, K.
    Kikuchi, Y.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 615 (02): : 242 - 244
  • [3] Digital pulse-shape processing for CdTe detectors
    Bargholtz, C
    Fumero, E
    Mårtensson, L
    Wachtmeister, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 290 - 292
  • [4] Sensitometric response of CdZnTe detectors for digital radiography
    Giakos, GC
    Pillai, B
    Chowdhury, S
    Dasgupta, A
    Guntupalli, R
    Suryananayanan, S
    IMTC/97 - IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE: SENSING, PROCESSING, NETWORKING, PROCEEDINGS VOLS 1 AND 2, 1997, : 12 - 15
  • [5] Image analysis of CdZnTe detectors for digital radiography
    Giakos, GC
    Vedantham, S
    Suryanarayanan, S
    Chowdhury, S
    Guntupalli, R
    Odogba, J
    Vega-Lozada, V
    Pillai, B
    Sheffer, DB
    WHERE INSTRUMENTATION IS GOING - CONFERENCE PROCEEDINGS, VOLS 1 AND 2, 1998, : 358 - 363
  • [6] Contrast study of CdZnTe detectors for digital mammography
    Giakos, G.C.
    Pillai, B.
    Chowdhury, S.
    Vedantham, S.
    Dasgupta, A.
    Sheffer, D.B.
    Davros, W.J.
    Passalaqua, A.
    Endorf, R.J.
    Journal of X-Ray Science and Technology, 1997, 7 (3-4): : 317 - 326
  • [7] Digital pulse processing for NaI(T1) detectors
    Di Fulvio, A.
    Shin, T. H.
    Hamel, M. C.
    Pozzi, S. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 806 : 169 - 174
  • [8] Electrical characterization of CdZnTe imaging detectors for digital radiography
    Vedantham, S
    Giakos, GC
    Dasgupta, A
    Pillai, B
    Chowdhury, S
    Ghotra, P
    PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 499 - 505
  • [9] Direct conversion Si and CdZnTe detectors for digital mammography
    Yin, S
    Tümer, TO
    Maeding, D
    Mainprize, J
    Mawdsley, G
    Yaffe, MJ
    Gordon, EE
    Hamilton, WJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 448 (03): : 591 - 597
  • [10] Giga-sample Pulse Acquisition and Digital Processing for Photomultiplier Detectors
    Walewski, W.
    Nowakowski, P. Nowak Vel