Electrochemical study of niclosamide at poly(3,4-ethylenedioxythiophene) modified glassy carbon electrode

被引:23
作者
Mehretie, Solomon [1 ]
Admassie, Shimelis [1 ]
Tessema, Merid [1 ]
Solomon, Theodros [1 ]
机构
[1] Univ Addis Ababa, Dept Chem, Addis Ababa, Ethiopia
关键词
Cyclic voltammetry; Differential pulse anodic stripping voltammetry; Glassy carbon; Niclosamide; Poly(3,4-ethylenedioxythiophene); PERFORMANCE LIQUID-CHROMATOGRAPHY; SPECTROPHOTOMETRIC DETERMINATION; ASCORBIC-ACID; BIOSENSOR; OXIDATION;
D O I
10.1016/j.snb.2012.02.035
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A poly(3,4-ethylenedioxythiophene) (PEDOT) modified glassy carbon electrode was constructed for the determination of niclosamide. Cyclic voltammetry and differential pulse anodic stripping voltammetry were used to study the electrochemical reaction of niclosamide at the modified electrode in pH 7.0 phosphate buffer solution. The PEDOT-modified electrode showed a very good electrochemical behavior with a significant enhancement of the peak current compared to the bare electrode. The pH oft he solution, accumulation potential and preconcentration time were optimized and the analytical performance of the modified electrode was investigated. A linear voltammetric response for niclosamide was obtained in the concentration range of 0.075-7.50 mu M, with a detection limit of 1.09 x 10(-8) M. The method was successfully applied for the determination of niclosamide in pharmaceutical formulation and biological sample. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 102
页数:6
相关论文
共 31 条
[1]   Spectrophotometric determination of niclosamide using p-benzoquinone [J].
AbdelFattah, SA .
SPECTROSCOPY LETTERS, 1997, 30 (05) :795-804
[2]   Detection of the damage caused to DNA by niclosamide using an electrochemical DNA-biosensor [J].
Abreu, FC ;
Goulart, MOF ;
Brett, AMO .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (11-12) :913-919
[3]  
Adrews P., 1982, PHARMACOL THERAPEUT, V19, P245
[4]   n- and p-doped poly(3,4-ethylenedioxythiophene): Two electronically conducting states of the polymer [J].
Ahonen, HJ ;
Lukkari, J ;
Kankare, J .
MACROMOLECULES, 2000, 33 (18) :6787-6793
[5]   Voltammetric determination of niclosamide at a glassy carbon electrode [J].
Alemu, H ;
Wagana, P ;
Tseki, PF .
ANALYST, 2002, 127 (01) :129-134
[6]  
[Anonymous], 1993, WHO TECHN REP SER
[7]   Optimization of the DPV potential waveform for determination of ascorbic acid on PEDOT-modified electrodes [J].
Bello, A. ;
Giannetto, M. ;
Mori, G. ;
Seeber, R. ;
Terzi, F. ;
Zanardi, C. .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 121 (02) :430-435
[8]   EXTRACTIVE ALKYLATION OF 5,2'-DICHLORO-4'-NITROSALICYLANILIDE (NICLOSAMIDE) FOR GAS-LIQUID-CHROMATOGRAPHIC ANALYSIS [J].
CHURCHILL, FC ;
KU, DN .
JOURNAL OF CHROMATOGRAPHY, 1980, 189 (03) :375-388
[9]   Selective differential spectrophotometric methods for determination of niclosamide and drotaverine hydrochloride [J].
Daabees, HG .
ANALYTICAL LETTERS, 2000, 33 (04) :639-656
[10]  
Faulkner L.R., 2000, Electrochemical Methods: Fundamentals and Applications, V2nd